[siemens_summary]
[catalog_children]
[catalog_search_products]

Inductive sensors ⍾ Page 12

Product detailsAdd to RFQ
NT5001 - Ifm
Inductive NAMUR sensor; Connection to switching amplifiers : yes; Switching amplifiers : connection to certified intrinsically safe circuits with the max. values: U = 15 V / I = 50 mA / P = 120 mW; Nominal voltage DC [V] : 8.2; (1kΩ); Supply voltage DC [V] : 7.5...30; (when used outside the hazardous area); Protection class : III; Electrical...
Product detailsAdd to RFQ
NS5002 - Ifm
Inductive NAMUR sensor; Connection to switching amplifiers : yes; Switching amplifiers : connection to certified intrinsically safe circuits with the max. values: U = 15 V / I = 50 mA / P = 120 mW; Nominal voltage DC [V] : 8.2; (1kΩ); Supply voltage DC [V] : 7.5...30; (when used outside the hazardous area); Electrical design : NAMUR; Output...
Product detailsAdd to RFQ
NS5003 - Ifm
Inductive NAMUR sensor; Connection to switching amplifiers : yes; Switching amplifiers : connection to certified intrinsically safe circuits with the max. values: U = 15 V / I = 50 mA / P = 120 mW; Nominal voltage DC [V] : 8.2; (1kΩ); Supply voltage DC [V] : 7.5...30; (when used outside the hazardous area); Protection class : III; Electrical...
Product detailsAdd to RFQ
NN5001 - Ifm
Inductive NAMUR sensor; Connection to switching amplifiers : yes; Switching amplifiers : connection to certified intrinsically safe circuits with the max. values: U = 15 V / I = 50 mA / P = 120 mW; Nominal voltage DC [V] : 8.2; (1kΩ); Supply voltage DC [V] : 7.5...30; (when used outside the hazardous area); Protection class : II; Electrical...
Product detailsAdd to RFQ
NM501A - Ifm
Inductive NAMUR sensor; Connection to switching amplifiers : yes; Switching amplifiers : connection to certified intrinsically safe circuits with the max. values: U = 15 V / I = 50 mA / P = 120 mW; Nominal voltage DC [V] : 8.2; (1kΩ); Supply voltage DC [V] : 7.5...30; (when used outside the hazardous area); Protection class : III; Electrical...
Product detailsAdd to RFQ
NN506A - Ifm
Inductive sensor; Connection to switching amplifiers : yes; Switching amplifiers : connection to certified intrinsically safe circuits with the max. values: U = 15 V / I = 50 mA / P = 120 mW; Operating voltage [V] : 8.2 DC; (1kΩ); Supply voltage DC [V] : 7.5...15; (when used outside the hazardous area); Protection class : III; Actuator wiring...
Product detailsAdd to RFQ
NN507A - Ifm
Inductive sensor; Connection to switching amplifiers : yes; Switching amplifiers : connection to certified intrinsically safe circuits with the max. values: U = 15 V / I = 50 mA / P = 120 mW; Operating voltage [V] : 8.2 DC; (1kΩ); Supply voltage DC [V] : 7.5...15; (when used outside the hazardous area); Protection class : III; Actuator wiring...
Product detailsAdd to RFQ
NI5011 - Ifm
Inductive NAMUR sensor; Connection to switching amplifiers : yes; Switching amplifiers : connection to certified intrinsically safe circuits with the max. values: U = 15 V / I = 50 mA / P = 120 mW; Nominal voltage DC [V] : 8.2; (1kΩ); Supply voltage DC [V] : 7.5...30; (when used outside the hazardous area); Protection class : II; Electrical...
Product detailsAdd to RFQ
NI5012 - Ifm
Inductive NAMUR sensor; Connection to switching amplifiers : yes; Switching amplifiers : connection to certified intrinsically safe circuits with the max. values: U = 15 V / I = 50 mA / P = 120 mW; Nominal voltage DC [V] : 8.2; (1kΩ); Supply voltage DC [V] : 7.5...30; (when used outside the hazardous area); Protection class : III; Electrical...
Product detailsAdd to RFQ
NI500A - Ifm
Inductive NAMUR sensor; Connection to switching amplifiers : yes; Switching amplifiers : connection to certified intrinsically safe circuits with the max. values: U = 15 V / I = 50 mA / P = 120 mW; Nominal voltage DC [V] : 8.2; (1kΩ); Supply voltage DC [V] : 7.5...30; (when used outside the hazardous area); Protection class : II; Electrical...
Product detailsAdd to RFQ
NI501A - Ifm
Inductive NAMUR sensor; Connection to switching amplifiers : yes; Switching amplifiers : connection to certified intrinsically safe circuits with the max. values: U = 15 V / I = 50 mA / P = 120 mW; Nominal voltage DC [V] : 8.2; (1kΩ); Supply voltage DC [V] : 7.5...30; (when used outside the hazardous area); Protection class : II; Electrical...
Product detailsAdd to RFQ
NG5021 - Ifm
Inductive NAMUR sensor; Connection to switching amplifiers : yes; Switching amplifiers : connection to certified intrinsically safe circuits with the max. values: U = 15 V / I = 50 mA / P = 120 mW; Nominal voltage DC [V] : 8.2; (1kΩ); Supply voltage DC [V] : 7.5...30; (when used outside the hazardous area); Protection class : II; Electrical...