[siemens_summary]
[catalog_children]
[catalog_search_products]

Industrial automation ⍾ Page 606

Product detailsAdd to RFQ
7MF4033-1DY10-1DB7-Z B11 - Siemens
SITRANS P DS III / P410, HART,4-20 mA transmitter for pressure Measuring cell filling silicone oil, normal cleaning Span: 0,16 ... 16 bar g (2.32 ... 232 psi g), overload limit 32 bar Version for diaphragm pressure controller. Consider additional delivery time for Remote seal. Remote seals must be ordered with an additional article no. Process connection: female thread 1/2-14...
Product detailsAdd to RFQ
7MF4033-1DY10-2AB6-Z A02 - Siemens
SITRANS P DS III / P410, HART,4-20 mA transmitter for pressure ****************************** Attention, product canceled / successor product available! Please get in touch with your Siemens contact to determine the successor product ****************************** Measuring cell filling silicone oil, normal cleaning Span: 0,16 ... 16 bar g (2.32 ... 232 psi g), overload limit 32 bar Version for diaphragm pressure controller....
Product detailsAdd to RFQ
7MF4033-1DY00-1AB6 - Siemens
SITRANS P DS III, HART,4-20 MA TRANSMITTER FOR PRESSURE MEASURING CELL FILLING SILICONE OIL, NORMAL CLEANING SPAN: 0,16 ... 16 BAR G (2.32 ... 232 PSI G), OVERLOAD LIMIT 32 BAR DESIGN FOR REMOTE SEALS. NOTE: PLEASE ADD THE DELIVERY TIME OF THE REMOTE SEAL! PROCESS CONNECTION: CONNECTION SHANK G1/2 B TO EN 837-1 DIE-CAST ALUMINIUM HOUSING STANDARD DESIGN NONE...
Product detailsAdd to RFQ
7MF4033-1DY00-2AC6-Z A01-Y01 - Siemens
SITRANS P DS III / P410, HART,4-20 mA transmitter for pressure
Product detailsAdd to RFQ
7MF4033-1DY00-2DB6-Z A01 - Siemens
SITRANS P DS III / P410, HART,4-20 mA transmitter for pressure Measuring cell filling silicone oil, normal cleaning Span: 0,16 ... 16 bar g (2.32 ... 232 psi g), overload limit 32 bar Version for diaphragm pressure controller. Consider additional delivery time for Remote seal. Remote seals must be ordered with an additional article no. Process connection: connection shank G1/2...
Product detailsAdd to RFQ
7MF4033-1DY00-1AB1-Z B11 - Siemens
SITRANS P DS III / P410, HART,4-20 mA transmitter for pressure Measuring cell filling silicone oil, normal cleaning Span: 0,16 ... 16 bar g (2.32 ... 232 psi g), overload limit 32 bar Design for remote seals. note: please add the delivery time of the remote seal! Process connection: connection shank G1/2 B to EN 837-1 Die-cast aluminium housing Standard...
Product detailsAdd to RFQ
7MF4033-1DY00-1AD6 - Siemens
SITRANS P DS III / P410, HART,4-20 MA TRANSMITTER FOR PRESSURE MEASURING CELL FILLING SILICONE OIL, NORMAL CLEANING SPAN: 0,16 ... 16 BAR G (2.32 ... 232 PSI G), OVERLOAD LIMIT 32 BAR DESIGN FOR REMOTE SEALS. NOTE: PLEASE ADD THE DELIVERY TIME OF THE REMOTE SEAL! PROCESS CONNECTION: CONNECTION SHANK G1/2 B TO EN 837-1 DIE-CAST ALUMINIUM HOUSING STANDARD...
Product detailsAdd to RFQ
7MF4033-1DY00-1AB7-Z A02 - Siemens
SITRANS P DS III / P410, HART,4-20 mA transmitter for pressure Measuring cell filling silicone oil, normal cleaning Span: 0,16 ... 16 bar g (2.32 ... 232 psi g), overload limit 32 bar Design for remote seals. note: please add the delivery time of the remote seal! Process connection: connection shank G1/2 B to EN 837-1 Die-cast aluminium housing Standard...
Product detailsAdd to RFQ
7MF4033-1DY00-1AB7-Z A01 - Siemens
SITRANS P DS III / P410, HART,4-20 mA transmitter for pressure Measuring cell filling silicone oil, normal cleaning Span: 0,16 ... 16 bar g (2.32 ... 232 psi g), overload limit 32 bar Design for remote seals. note: please add the delivery time of the remote seal! Process connection: connection shank G1/2 B to EN 837-1 Die-cast aluminium housing Standard...
Product detailsAdd to RFQ
7MF4033-1DC00-2AB6-Z A02 - Siemens
SITRANS P DS III / P410, HART,4-20 mA transmitter for pressure Measuring cell filling silicone oil, normal cleaning Span: 0,16 ... 16 bar g (2.32 ... 232 psi g), overload limit 32 bar Diaphragm hastelloy measuring cell hastelloy Process connection: connection shank G1/2 B to EN 837-1 Die-cast aluminium housing International design english inscription and documentation as cd None explosion...
Product detailsAdd to RFQ
7MF4033-1DC10-2AB7-Z A02 - Siemens
SITRANS P DS III / P410, HART,4-20 mA transmitter for pressure Measuring cell filling silicone oil, normal cleaning Span: 0,16 ... 16 bar g (2.32 ... 232 psi g), overload limit 32 bar Diaphragm hastelloy measuring cell hastelloy Process connection: female thread 1/2-14 npt Die-cast aluminium housing International design english inscription and documentation as cd None explosion protection Electric connection...
Product detailsAdd to RFQ
7MF4033-1DC10-2AC6-Z A02 - Siemens
SITRANS P DS III / P410, HART,4-20 mA transmitter for pressure Measuring cell filling silicone oil, normal cleaning Span: 0,16 ... 16 bar g (2.32 ... 232 psi g), overload limit 32 bar Diaphragm hastelloy measuring cell hastelloy Process connection: female thread 1/2-14 npt Die-cast aluminium housing International design english inscription and documentation as cd None explosion protection Electric connection...