[siemens_summary]
[catalog_children]
[catalog_search_products]

KNX ⍾ Page 41

Product detailsAdd to RFQ
2CDG110209R0011 - Abb
For the control of fan coil units. Via one electronic output, a thermoelectric valve drive can be controlled for heating and cooling. For the fan control the devices features three relay outputs. Over 4 inputs the room status can be detected and monitored (Use for window contact, dew point sensor, level sensor or temperature sensor). Also it is possible to...
Product detailsAdd to RFQ
2CDG110212R0011 - Abb
For the control of fan coil units. Via two analog outputs, two analog valves or one 6-way valve drive can be controlled for heating and cooling. For the fan control the devices features three relay outputs. A relay output switches an additional load of up to 10 A, such as auxiliary heating. Over 4 inputs the room status can be...
Product detailsAdd to RFQ
2CDG110205R0011 - Abb
Automation Controller with pre-defined Automation Modules for a holistic Heating, Ventilation and Air Conditioning (HVAC) Automation Solution from Central HVAC to Room Automation to meet the Energy Efficiencies Objectives like EN 15232 or LEED. Automation Modules for example Schedule, Set Point Calculation, Heat Curve Calculation, Data Logging and Device Monitoring. Own Automation Modules can be created by a graphical Logic...
Product detailsAdd to RFQ
2CDG110177R0011 - Abb
Connects the KNX bus with the Ethernet network. The device uses the KNXnet/IP protocol for communication (Tunneling). KNX devices can be programmed via the LAN using ETS. For this and further clients 5 Tunneling Server are available. The IP address can be fixed or can be received from a DHCP server. Power supply via 12..30 V DC or PoE.
Product detailsAdd to RFQ
2CDG110184R0011 - Abb
The weather unit WZ/S is used to detect and process weather data from the weather sensor. The weather sensor is providing data for twilight, brightness in 3 directions, rain, temperature, information on day/night, wind speed, date and time. 4 value memory stands for order, per value memory can 24 values be stored. The weather unit can only be used with...
Product detailsAdd to RFQ
2CDG110203R0011 - Abb
The Analogue Actuator converts KNX telegrams in voltage (0…10V) signals. These analogue output signals are used to influence regulatory processes. For example, devices for heating, air conditioning or ventilation applications can be adjusted in their operation depending on the information, which are transmitted via the bus system. This Analogue Actuator is a 2-fold device with a housing for surface mounting....
Product detailsAdd to RFQ
2CDG110199R0011 - Abb
For controlling DALI devices via the ABB i-bus®. Two DALI output for up to 2x64 DALI slaves. DALI power supply is integrated. Control and status feedback is carried out via KNX per DALI slave (2x64), with groups (2x16), together in broadcast or per scenes (2x16). Extensive fault and error messages are available Self-contained emergency converter (2x64) acc. EN 62386-202 will...
Product detailsAdd to RFQ
2CDG110190R0011 - Abb
The analogue input is used to detect and process 4 independent input signals. E.g. 0-1 V, 0-5 V, 0-10 V, 0-20 mA, 4-20 mA, 0-1000 Ohm, PT100, PT1000 and floating contacts. Integrated power supply to generate the 24 V DC voltage for external sensors. The device can be operated with a suppy voltage of 115 to 230 V, 50/60 Hz....
Product detailsAdd to RFQ
2CDG110196R0011 - Abb
Controls typical fan coil units by two analogue outputs for 0 - 10 V valve drives and a 3 channel output for fan with up to 3 stages. Also a additional load (up to 16 A) like a auxiliary heating can be controlled by a switch output. Window sensors, condensed water sensors and temperature sensors can be connected to the...
Product detailsAdd to RFQ
2CDG110192R0011 - Abb
Provides extensive logic functions. The logic editor is integrated into the ETS. Up to 3000 logic gates are possible. Simulation for testing. User-defined function blocks can be created and saved. Requires 24 V DC auxiliary voltage or PoE alternatively.
Product detailsAdd to RFQ
2CDG110202R0011 - Abb
The Analogue Actuator converts KNX telegrams in voltage (0...10V) or current (0…24mA) signals. These analogue output signals are used to influence regulatory processes. For example, devices for heating, air conditioning or ventilation applications can be adjusted in their operation depending on the information, which are transmitted via the bus system. This Analogue Actuator is a 4-fold DIN rail device. The...
Product detailsAdd to RFQ
2CDG110191R0011 - Abb
The weather station is used to detect and process 4 independent input signals acc. DIN IEC 60381 (0-1 V, 0-5 V, 0-10 V, 0-20 mA, 4-20 mA, 0-1000 Ohm, PT100, PT1000 and floating contacts). Integrated power supply to generate the 24 V DC voltage for external sensors. The device can be operated with a suppy voltage of 115 to 230...