[siemens_summary]
[catalog_children]
[catalog_search_products]
Level sensors

Level sensors

Items 1909 - 1920 of 1975 from SICK ⍾ Last modified Sep 3, 2025

Level sensors ⍾ Page 160

Product detailsAdd to RFQ
CFP0900-XPXNNAX - Sick
Features: Medium: Water and oil-based liquids; Measurement: Switch, Continuous; Probe length: 900 mm; Process pressure: –0.5 bar ... 3 bar; Process temperature: –20 °C ... +80 °C; UL approval: ✔; RoHS certificate: ✔; IO-Link: ✔; Performance: Accuracy of sensor element: ± 15 mm (with water or oil under reference conditions); Reproducibility: < 5 mm; Resolution: < 2 mm; Response time:...
Product detailsAdd to RFQ
CFP0800-XPXNNCT - Sick
Features: Medium: Water and oil-based liquids; Measurement: Switch, Continuous; Probe length: 800 mm; Process pressure: –0.5 bar ... 3 bar; Process temperature: –20 °C ... +80 °C; UL approval: ✔; RoHS certificate: ✔; IO-Link: ✔; Performance: Accuracy of sensor element: ± 15 mm (with water or oil under reference conditions); Reproducibility: < 5 mm; Resolution: < 2 mm; Response time:...
Product detailsAdd to RFQ
CFP0900-XPANNAX - Sick
Features: Medium: Water and oil-based liquids; Measurement: Switch, Continuous; Probe length: 900 mm; Process pressure: –0.5 bar ... 3 bar; Process temperature: –20 °C ... +80 °C; UL approval: ✔; RoHS certificate: ✔; IO-Link: ✔; Performance: Accuracy of sensor element: ± 15 mm (with water or oil under reference conditions); Reproducibility: < 5 mm; Resolution: < 2 mm; Response time:...
Product detailsAdd to RFQ
CFP0900-XPBNNAX - Sick
Features: Medium: Water and oil-based liquids; Measurement: Switch, Continuous; Probe length: 900 mm; Process pressure: –0.5 bar ... 3 bar; Process temperature: –20 °C ... +80 °C; UL approval: ✔; RoHS certificate: ✔; IO-Link: ✔; Performance: Accuracy of sensor element: ± 15 mm (with water or oil under reference conditions); Reproducibility: < 5 mm; Resolution: < 2 mm; Response time:...
Product detailsAdd to RFQ
CFP0800-XPANNBX - Sick
Features: Medium: Water and oil-based liquids; Measurement: Switch, Continuous; Probe length: 800 mm; Process pressure: –0.5 bar ... 3 bar; Process temperature: –20 °C ... +80 °C; UL approval: ✔; RoHS certificate: ✔; IO-Link: ✔; Performance: Accuracy of sensor element: ± 15 mm (with water or oil under reference conditions); Reproducibility: < 5 mm; Resolution: < 2 mm; Response time:...
Product detailsAdd to RFQ
CFP0700-XPANNAX - Sick
Features: Medium: Water and oil-based liquids; Measurement: Switch, Continuous; Probe length: 700 mm; Process pressure: –0.5 bar ... 3 bar; Process temperature: –20 °C ... +80 °C; UL approval: ✔; RoHS certificate: ✔; IO-Link: ✔; Performance: Accuracy of sensor element: ± 15 mm (with water or oil under reference conditions); Reproducibility: < 5 mm; Resolution: < 2 mm; Response time:...
Product detailsAdd to RFQ
CFP0800-XPANNAX - Sick
Features: Medium: Water and oil-based liquids; Measurement: Switch, Continuous; Probe length: 800 mm; Process pressure: –0.5 bar ... 3 bar; Process temperature: –20 °C ... +80 °C; UL approval: ✔; RoHS certificate: ✔; IO-Link: ✔; Performance: Accuracy of sensor element: ± 15 mm (with water or oil under reference conditions); Reproducibility: < 5 mm; Resolution: < 2 mm; Response time:...
Product detailsAdd to RFQ
CFP0700-XPXNNBX - Sick
Features: Medium: Water and oil-based liquids; Measurement: Switch, Continuous; Probe length: 700 mm; Process pressure: –0.5 bar ... 3 bar; Process temperature: –20 °C ... +80 °C; UL approval: ✔; RoHS certificate: ✔; IO-Link: ✔; Performance: Accuracy of sensor element: ± 15 mm (with water or oil under reference conditions); Reproducibility: < 5 mm; Resolution: < 2 mm; Response time:...
Product detailsAdd to RFQ
CFP0700-XPBNNAX - Sick
Features: Medium: Water and oil-based liquids; Measurement: Switch, Continuous; Probe length: 700 mm; Process pressure: –0.5 bar ... 3 bar; Process temperature: –20 °C ... +80 °C; UL approval: ✔; RoHS certificate: ✔; IO-Link: ✔; Performance: Accuracy of sensor element: ± 15 mm (with water or oil under reference conditions); Reproducibility: < 5 mm; Resolution: < 2 mm; Response time:...
Product detailsAdd to RFQ
CFP0700-XPXNNCT - Sick
Features: Medium: Water and oil-based liquids; Measurement: Switch, Continuous; Probe length: 700 mm; Process pressure: –0.5 bar ... 3 bar; Process temperature: –20 °C ... +80 °C; UL approval: ✔; RoHS certificate: ✔; IO-Link: ✔; Performance: Accuracy of sensor element: ± 15 mm (with water or oil under reference conditions); Reproducibility: < 5 mm; Resolution: < 2 mm; Response time:...
Product detailsAdd to RFQ
CFP0800-XPANNCT - Sick
Features: Medium: Water and oil-based liquids; Measurement: Switch, Continuous; Probe length: 800 mm; Process pressure: –0.5 bar ... 3 bar; Process temperature: –20 °C ... +80 °C; UL approval: ✔; RoHS certificate: ✔; IO-Link: ✔; Performance: Accuracy of sensor element: ± 15 mm (with water or oil under reference conditions); Reproducibility: < 5 mm; Resolution: < 2 mm; Response time:...
Product detailsAdd to RFQ
CFP0700-XPANNCT - Sick
Features: Medium: Water and oil-based liquids; Measurement: Switch, Continuous; Probe length: 700 mm; Process pressure: –0.5 bar ... 3 bar; Process temperature: –20 °C ... +80 °C; UL approval: ✔; RoHS certificate: ✔; IO-Link: ✔; Performance: Accuracy of sensor element: ± 15 mm (with water or oil under reference conditions); Reproducibility: < 5 mm; Resolution: < 2 mm; Response time:...