LFV230-XXTGATPM0080 - Sick
Features: Medium: Fluids; Measurement: Switch; Probe length: 80 mm; Process pressure: –1 bar ... 64 bar; Process temperature: –40 °C ... +150 °C; Fill material density: 0.7 g/cm³ ... 2.5 g/cm³; Performance: Accuracy of sensor element: ± 2 mm; Reproducibility: ≤ 1 mm; Viscosity: 0.1 mPas ... 10,000 mPas; Resolution: ≤ 1 mm; Response time: 500 ms; MTBF: 1,3*10^7 h;...
Product detailsAdd to RFQ
LFV230-XXTGACPV0300 - Sick
Features: Medium: Fluids; Measurement: Switch; Probe length: 300 mm; Process pressure: –1 bar ... 64 bar; Process temperature: –40 °C ... +150 °C; Fill material density: 0.7 g/cm³ ... 2.5 g/cm³; Performance: Accuracy of sensor element: ± 2 mm; Reproducibility: ≤ 1 mm; Viscosity: 0.1 mPas ... 10,000 mPas; Resolution: ≤ 1 mm; Response time: 500 ms; MTBF: 1,3*10^7 h;...
Product detailsAdd to RFQ
LFV230-XXTGACPV0160 - Sick
Features: Medium: Fluids; Measurement: Switch; Probe length: 160 mm; Process pressure: –1 bar ... 64 bar; Process temperature: –40 °C ... +150 °C; Fill material density: 0.7 g/cm³ ... 2.5 g/cm³; Performance: Accuracy of sensor element: ± 2 mm; Reproducibility: ≤ 1 mm; Viscosity: 0.1 mPas ... 10,000 mPas; Resolution: ≤ 1 mm; Response time: 500 ms; MTBF: 1,3*10^7 h;...
Product detailsAdd to RFQ
LFV230-XXTGBTPM0100 - Sick
Vibrating level switch, LFV230. Probe length / Detection range: 100 mm. Process pressure: -1 bar ... 64 bar. Process temperature: -40 °C ... 150 °C. Housing material: Stainless steel 1.4404, PEI.
Product detailsAdd to RFQ
LFV230-XXTGACPV0080 - Sick
Features: Medium: Fluids; Measurement: Switch; Probe length: 80 mm; Process pressure: –1 bar ... 64 bar; Process temperature: –40 °C ... +150 °C; Fill material density: 0.7 g/cm³ ... 2.5 g/cm³; Performance: Accuracy of sensor element: ± 2 mm; Reproducibility: ≤ 1 mm; Viscosity: 0.1 mPas ... 10,000 mPas; Resolution: ≤ 1 mm; Response time: 500 ms; MTBF: 1,3*10^7 h;...
Product detailsAdd to RFQ
LFV230-XXTGATPM0100 - Sick
Features: Medium: Fluids; Measurement: Switch; Probe length: 100 mm; Process pressure: –1 bar ... 64 bar; Process temperature: –40 °C ... +150 °C; Fill material density: 0.7 g/cm³ ... 2.5 g/cm³; Performance: Accuracy of sensor element: ± 2 mm; Reproducibility: ≤ 1 mm; Viscosity: 0.1 mPas ... 10,000 mPas; Resolution: ≤ 1 mm; Response time: 500 ms; MTBF: 1,3*10^7 h;...
Product detailsAdd to RFQ
LFV230-XXTGATPM0300 - Sick
Features: Medium: Fluids; Measurement: Switch; Probe length: 300 mm; Process pressure: –1 bar ... 64 bar; Process temperature: –40 °C ... +150 °C; Fill material density: 0.7 g/cm³ ... 2.5 g/cm³; Performance: Accuracy of sensor element: ± 2 mm; Reproducibility: ≤ 1 mm; Viscosity: 0.1 mPas ... 10,000 mPas; Resolution: ≤ 1 mm; Response time: 500 ms; MTBF: 1,3*10^7 h;...
Product detailsAdd to RFQ
LFV230-XXTGATPM0250 - Sick
Features: Medium: Fluids; Measurement: Switch; Probe length: 250 mm; Process pressure: –1 bar ... 64 bar; Process temperature: –40 °C ... +150 °C; Fill material density: 0.7 g/cm³ ... 2.5 g/cm³; Performance: Accuracy of sensor element: ± 2 mm; Reproducibility: ≤ 1 mm; Viscosity: 0.1 mPas ... 10,000 mPas; Resolution: ≤ 1 mm; Response time: 500 ms; MTBF: 1,3*10^7 h;...
Product detailsAdd to RFQ
LFV230-XXSNBTPM2400 - Sick
Vibrating level switch, LFV230. Probe length / Detection range: 2,400 mm. Process pressure: -1 bar ... 64 bar. Process temperature: -40 °C ... 100 °C. Housing material: Stainless steel 1.4404, PEI.
Product detailsAdd to RFQ
LFV230-XXTGATPV0115 - Sick
Features: Medium: Fluids; Measurement: Switch; Probe length: 115 mm; Process pressure: –1 bar ... 64 bar; Process temperature: –40 °C ... +150 °C; Fill material density: 0.7 g/cm³ ... 2.5 g/cm³; Performance: Accuracy of sensor element: ± 2 mm; Reproducibility: ≤ 1 mm; Viscosity: 0.1 mPas ... 10,000 mPas; Resolution: ≤ 1 mm; Response time: 500 ms; MTBF: 1,3*10^7 h;...
Product detailsAdd to RFQ
LFV230-XXSNBTPM2500 - Sick
Vibrating level switch, LFV230. Probe length / Detection range: 2,500 mm. Process pressure: -1 bar ... 64 bar. Process temperature: -40 °C ... 100 °C. Housing material: Stainless steel 1.4404, PEI.
Product detailsAdd to RFQ
LFV230-XXTGATPM0200 - Sick
Features: Medium: Fluids; Measurement: Switch; Probe length: 200 mm; Process pressure: –1 bar ... 64 bar; Process temperature: –40 °C ... +150 °C; Fill material density: 0.7 g/cm³ ... 2.5 g/cm³; Performance: Accuracy of sensor element: ± 2 mm; Reproducibility: ≤ 1 mm; Viscosity: 0.1 mPas ... 10,000 mPas; Resolution: ≤ 1 mm; Response time: 500 ms; MTBF: 1,3*10^7 h;...