[siemens_summary]
[catalog_children]
[catalog_search_products]

LFV200 ⍾ Page 1

Product detailsAdd to RFQ
LFV230-XXTNBTPV0084 - Sick
Features: Medium: Fluids; Measurement: Switch; Probe length: 84 mm; Process pressure: –1 bar ... 64 bar; Process temperature: –40 °C ... +150 °C; Fill material density: 0.7 g/cm³ ... 2.5 g/cm³; Performance: Accuracy of sensor element: ± 2 mm; Reproducibility: ≤ 1 mm; Viscosity: 0.1 mPas ... 10,000 mPas; Resolution: ≤ 1 mm; Response time: 500 ms; MTBF: 1,3*10^7 h;...
Product detailsAdd to RFQ
LFV230-XXTNBTPV0148 - Sick
Features: Medium: Fluids; Measurement: Switch; Probe length: 148 mm; Process pressure: –1 bar ... 64 bar; Process temperature: –40 °C ... +150 °C; Fill material density: 0.7 g/cm³ ... 2.5 g/cm³; Performance: Accuracy of sensor element: ± 2 mm; Reproducibility: ≤ 1 mm; Viscosity: 0.1 mPas ... 10,000 mPas; Resolution: ≤ 1 mm; Response time: 500 ms; MTBF: 1,3*10^7 h;...
Product detailsAdd to RFQ
LFV230-XXTNBTPV0080 - Sick
Features: Medium: Fluids; Measurement: Switch; Probe length: 80 mm; Process pressure: –1 bar ... 64 bar; Process temperature: –40 °C ... +150 °C; Fill material density: 0.7 g/cm³ ... 2.5 g/cm³; Performance: Accuracy of sensor element: ± 2 mm; Reproducibility: ≤ 1 mm; Viscosity: 0.1 mPas ... 10,000 mPas; Resolution: ≤ 1 mm; Response time: 500 ms; MTBF: 1,3*10^7 h;...
Product detailsAdd to RFQ
LFV230-XXTNBTPV0100 - Sick
Features: Medium: Fluids; Measurement: Switch; Probe length: 100 mm; Process pressure: –1 bar ... 64 bar; Process temperature: –40 °C ... +150 °C; Fill material density: 0.7 g/cm³ ... 2.5 g/cm³; Performance: Accuracy of sensor element: ± 2 mm; Reproducibility: ≤ 1 mm; Viscosity: 0.1 mPas ... 10,000 mPas; Resolution: ≤ 1 mm; Response time: 500 ms; MTBF: 1,3*10^7 h;...
Product detailsAdd to RFQ
LFV230-XXTGBTPV0135 - Sick
Features: Medium: Fluids; Measurement: Switch; Probe length: 135 mm; Process pressure: –1 bar ... 64 bar; Process temperature: –40 °C ... +150 °C; Fill material density: 0.7 g/cm³ ... 2.5 g/cm³; Performance: Accuracy of sensor element: ± 2 mm; Reproducibility: ≤ 1 mm; Viscosity: 0.1 mPas ... 10,000 mPas; Resolution: ≤ 1 mm; Response time: 500 ms; MTBF: 1,3*10^7 h;...
Product detailsAdd to RFQ
LFV230-XXTGBTPM0150 - Sick
Features: Medium: Fluids; Measurement: Switch; Probe length: 150 mm; Process pressure: –1 bar ... 64 bar; Process temperature: –40 °C ... +150 °C; Fill material density: 0.7 g/cm³ ... 2.5 g/cm³; Performance: Accuracy of sensor element: ± 2 mm; Reproducibility: ≤ 1 mm; Viscosity: 0.1 mPas ... 10,000 mPas; Resolution: ≤ 1 mm; Response time: 500 ms; MTBF: 1,3*10^7 h;...
Product detailsAdd to RFQ
LFV230-XXTGBTPM0250 - Sick
Features: Medium: Fluids; Measurement: Switch; Probe length: 250 mm; Process pressure: –1 bar ... 64 bar; Process temperature: –40 °C ... +150 °C; Fill material density: 0.7 g/cm³ ... 2.5 g/cm³; Performance: Accuracy of sensor element: ± 2 mm; Reproducibility: ≤ 1 mm; Viscosity: 0.1 mPas ... 10,000 mPas; Resolution: ≤ 1 mm; Response time: 500 ms; MTBF: 1,3*10^7 h;...
Product detailsAdd to RFQ
LFV230-XXTGBTPM0130 - Sick
Features: Medium: Fluids; Measurement: Switch; Probe length: 130 mm; Process pressure: –1 bar ... 64 bar; Process temperature: –40 °C ... +150 °C; Fill material density: 0.7 g/cm³ ... 2.5 g/cm³; Performance: Accuracy of sensor element: ± 2 mm; Reproducibility: ≤ 1 mm; Viscosity: 0.1 mPas ... 10,000 mPas; Resolution: ≤ 1 mm; Response time: 500 ms; MTBF: 1,3*10^7 h;...
Product detailsAdd to RFQ
LFV230-XXTGBTPM0350 - Sick
Features: Medium: Fluids; Measurement: Switch; Probe length: 350 mm; Process pressure: –1 bar ... 64 bar; Process temperature: –40 °C ... +150 °C; Fill material density: 0.7 g/cm³ ... 2.5 g/cm³; Performance: Accuracy of sensor element: ± 2 mm; Reproducibility: ≤ 1 mm; Viscosity: 0.1 mPas ... 10,000 mPas; Resolution: ≤ 1 mm; Response time: 500 ms; MTBF: 1,3*10^7 h;...
Product detailsAdd to RFQ
LFV230-XXTGBTPM0450 - Sick
Features: Medium: Fluids; Measurement: Switch; Probe length: 450 mm; Process pressure: –1 bar ... 64 bar; Process temperature: –40 °C ... +150 °C; Fill material density: 0.7 g/cm³ ... 2.5 g/cm³; Performance: Accuracy of sensor element: ± 2 mm; Reproducibility: ≤ 1 mm; Viscosity: 0.1 mPas ... 10,000 mPas; Resolution: ≤ 1 mm; Response time: 500 ms; MTBF: 1,3*10^7 h;...
Product detailsAdd to RFQ
LFV230-XXTGATPV0150 - Sick
Features: Medium: Fluids; Measurement: Switch; Probe length: 150 mm; Process pressure: –1 bar ... 64 bar; Process temperature: –40 °C ... +150 °C; Fill material density: 0.7 g/cm³ ... 2.5 g/cm³; Performance: Accuracy of sensor element: ± 2 mm; Reproducibility: ≤ 1 mm; Viscosity: 0.1 mPas ... 10,000 mPas; Resolution: ≤ 1 mm; Response time: 500 ms; MTBF: 1,3*10^7 h;...
Product detailsAdd to RFQ
LFV230-XXTGATPV0160 - Sick
Features: Medium: Fluids; Measurement: Switch; Probe length: 160 mm; Process pressure: –1 bar ... 64 bar; Process temperature: –40 °C ... +150 °C; Fill material density: 0.7 g/cm³ ... 2.5 g/cm³; Performance: Accuracy of sensor element: ± 2 mm; Reproducibility: ≤ 1 mm; Viscosity: 0.1 mPas ... 10,000 mPas; Resolution: ≤ 1 mm; Response time: 500 ms; MTBF: 1,3*10^7 h;...