LFV230-XXS / LFV200

LFV230-XXS / LFV200

Items 1 - 12 of 83 from SICK ⍾ Last modified Sep 4, 2025

LFV230-XXS / LFV200 ⍾ Page 1

Product detailsAdd to RFQ
LFV230-XXSNBTPM0340 - Sick
Features: Medium: Fluids; Measurement: Switch; Probe length: 340 mm; Process pressure: –1 bar ... 64 bar; Process temperature: –40 °C ... +100 °C; Fill material density: 0.7 g/cm³ ... 2.5 g/cm³; Performance: Accuracy of sensor element: ± 2 mm; Reproducibility: ≤ 1 mm; Viscosity: 0.1 mPas ... 10,000 mPas; Resolution: ≤ 1 mm; Response time: 500 ms; MTBF: 1,3*10^7 h;...
Product detailsAdd to RFQ
LFV230-XXSNBTPM0100 - Sick
Features: Medium: Fluids; Measurement: Switch; Probe length: 100 mm; Process pressure: –1 bar ... 64 bar; Process temperature: –40 °C ... +100 °C; Fill material density: 0.7 g/cm³ ... 2.5 g/cm³; Performance: Accuracy of sensor element: ± 2 mm; Reproducibility: ≤ 1 mm; Viscosity: 0.1 mPas ... 10,000 mPas; Resolution: ≤ 1 mm; Response time: 500 ms; MTBF: 1,3*10^7 h;...
Product detailsAdd to RFQ
LFV230-XXSNBTPM0270 - Sick
Features: Medium: Fluids; Measurement: Switch; Probe length: 270 mm; Process pressure: –1 bar ... 64 bar; Process temperature: –40 °C ... +100 °C; Fill material density: 0.7 g/cm³ ... 2.5 g/cm³; Performance: Accuracy of sensor element: ± 2 mm; Reproducibility: ≤ 1 mm; Viscosity: 0.1 mPas ... 10,000 mPas; Resolution: ≤ 1 mm; Response time: 500 ms; MTBF: 1,3*10^7 h;...
Product detailsAdd to RFQ
LFV230-XXSGBTPV0100 - Sick
Features: Medium: Fluids; Measurement: Switch; Probe length: 100 mm; Process pressure: –1 bar ... 64 bar; Process temperature: –40 °C ... +100 °C; Fill material density: 0.7 g/cm³ ... 2.5 g/cm³; Performance: Accuracy of sensor element: ± 2 mm; Reproducibility: ≤ 1 mm; Viscosity: 0.1 mPas ... 10,000 mPas; Resolution: ≤ 1 mm; Response time: 500 ms; MTBF: 1,3*10^7 h;...
Product detailsAdd to RFQ
LFV230-XXSGBTPV0150 - Sick
Features: Medium: Fluids; Measurement: Switch; Probe length: 150 mm; Process pressure: –1 bar ... 64 bar; Process temperature: –40 °C ... +100 °C; Fill material density: 0.7 g/cm³ ... 2.5 g/cm³; Performance: Accuracy of sensor element: ± 2 mm; Reproducibility: ≤ 1 mm; Viscosity: 0.1 mPas ... 10,000 mPas; Resolution: ≤ 1 mm; Response time: 500 ms; MTBF: 1,3*10^7 h;...
Product detailsAdd to RFQ
LFV230-XXSGBTPV0600 - Sick
Features: Medium: Fluids; Measurement: Switch; Probe length: 600 mm; Process pressure: –1 bar ... 64 bar; Process temperature: –40 °C ... +100 °C; Fill material density: 0.7 g/cm³ ... 2.5 g/cm³; Performance: Accuracy of sensor element: ± 2 mm; Reproducibility: ≤ 1 mm; Viscosity: 0.1 mPas ... 10,000 mPas; Resolution: ≤ 1 mm; Response time: 500 ms; MTBF: 1,3*10^7 h;...
Product detailsAdd to RFQ
LFV230-XXSNATPM0150 - Sick
Features: Medium: Fluids; Measurement: Switch; Probe length: 150 mm; Process pressure: –1 bar ... 64 bar; Process temperature: –40 °C ... +100 °C; Fill material density: 0.7 g/cm³ ... 2.5 g/cm³; Performance: Accuracy of sensor element: ± 2 mm; Reproducibility: ≤ 1 mm; Viscosity: 0.1 mPas ... 10,000 mPas; Resolution: ≤ 1 mm; Response time: 500 ms; MTBF: 1,3*10^7 h;...
Product detailsAdd to RFQ
LFV230-XXSGBTPV0500 - Sick
Features: Medium: Fluids; Measurement: Switch; Probe length: 500 mm; Process pressure: –1 bar ... 64 bar; Process temperature: –40 °C ... +100 °C; Fill material density: 0.7 g/cm³ ... 2.5 g/cm³; Performance: Accuracy of sensor element: ± 2 mm; Reproducibility: ≤ 1 mm; Viscosity: 0.1 mPas ... 10,000 mPas; Resolution: ≤ 1 mm; Response time: 500 ms; MTBF: 1,3*10^7 h;...
Product detailsAdd to RFQ
LFV230-XXSGBTPV0200 - Sick
Features: Medium: Fluids; Measurement: Switch; Probe length: 200 mm; Process pressure: –1 bar ... 64 bar; Process temperature: –40 °C ... +100 °C; Fill material density: 0.7 g/cm³ ... 2.5 g/cm³; Performance: Accuracy of sensor element: ± 2 mm; Reproducibility: ≤ 1 mm; Viscosity: 0.1 mPas ... 10,000 mPas; Resolution: ≤ 1 mm; Response time: 500 ms; MTBF: 1,3*10^7 h;...
Product detailsAdd to RFQ
LFV230-XXSGBTPV0400 - Sick
Features: Medium: Fluids; Measurement: Switch; Probe length: 400 mm; Process pressure: –1 bar ... 64 bar; Process temperature: –40 °C ... +100 °C; Fill material density: 0.7 g/cm³ ... 2.5 g/cm³; Performance: Accuracy of sensor element: ± 2 mm; Reproducibility: ≤ 1 mm; Viscosity: 0.1 mPas ... 10,000 mPas; Resolution: ≤ 1 mm; Response time: 500 ms; MTBF: 1,3*10^7 h;...
Product detailsAdd to RFQ
LFV230-XXSNATPM0600 - Sick
Features: Medium: Fluids; Measurement: Switch; Probe length: 600 mm; Process pressure: –1 bar ... 64 bar; Process temperature: –40 °C ... +100 °C; Fill material density: 0.7 g/cm³ ... 2.5 g/cm³; Performance: Accuracy of sensor element: ± 2 mm; Reproducibility: ≤ 1 mm; Viscosity: 0.1 mPas ... 10,000 mPas; Resolution: ≤ 1 mm; Response time: 500 ms; MTBF: 1,3*10^7 h;...
Product detailsAdd to RFQ
LFV230-XXSNBCPV0300 - Sick
Features: Medium: Fluids; Measurement: Switch; Probe length: 300 mm; Process pressure: –1 bar ... 64 bar; Process temperature: –40 °C ... +100 °C; Fill material density: 0.7 g/cm³ ... 2.5 g/cm³; Performance: Accuracy of sensor element: ± 2 mm; Reproducibility: ≤ 1 mm; Viscosity: 0.1 mPas ... 10,000 mPas; Resolution: ≤ 1 mm; Response time: 500 ms; MTBF: 1,3*10^7 h;...