[siemens_summary]
[catalog_children]
[catalog_search_products]

LFV300 ⍾ Page 2

Product detailsAdd to RFQ
LFV330-XXNAVXPR0400 - Sick
Features: Medium: Fluids; Measurement: Switch; Probe length: 400 mm; Process pressure: –1 bar ... 64 bar; Process temperature: –50 °C ... +150 °C; Fill material density: 0.5 g/cm³ ... 2.5 g/cm³; Performance: Accuracy of sensor element: ± 2 mm; Reproducibility: ≤ 1 mm; Viscosity: 0.1 mPas ... 10,000 mPas; Response time: 500 ms; Electronics: Power consumption: 5 mA ... 30...
Product detailsAdd to RFQ
LFV330-XXGCVXPR1000 - Sick
Features: Medium: Fluids; Measurement: Switch; Probe length: 1,000 mm; Process pressure: –1 bar ... 64 bar; Process temperature: –50 °C ... +150 °C; Fill material density: 0.5 g/cm³ ... 2.5 g/cm³; Performance: Accuracy of sensor element: ± 2 mm; Reproducibility: ≤ 1 mm; Viscosity: 0.1 mPas ... 10,000 mPas; Response time: 500 ms; Electronics: Power consumption: 5 mA ... 30...
Product detailsAdd to RFQ
LFV330-XXGCVX8R0200 - Sick
Features: Medium: Fluids; Measurement: Switch; Probe length: 200 mm; Process pressure: –1 bar ... 64 bar; Process temperature: –50 °C ... +150 °C; Fill material density: 0.5 g/cm³ ... 2.5 g/cm³; Performance: Accuracy of sensor element: ± 2 mm; Reproducibility: ≤ 1 mm; Viscosity: 0.1 mPas ... 10,000 mPas; Response time: 500 ms; Electronics: Power consumption: 5 mA ... 30...
Product detailsAdd to RFQ
LFV330-XXGBVXVR0100 - Sick
Features: Medium: Fluids; Measurement: Switch; Probe length: 100 mm; Process pressure: –1 bar ... 64 bar; Process temperature: –50 °C ... +150 °C; Fill material density: 0.5 g/cm³ ... 2.5 g/cm³; Performance: Accuracy of sensor element: ± 2 mm; Reproducibility: ≤ 1 mm; Viscosity: 0.1 mPas ... 10,000 mPas; Response time: 500 ms; Electronics: Power consumption: 5 mA ... 30...
Product detailsAdd to RFQ
LFV330-XXGBVXPT1600 - Sick
Features: Medium: Fluids; Measurement: Switch; Probe length: 1,600 mm; Process pressure: –1 bar ... 64 bar; Process temperature: –50 °C ... +150 °C; Fill material density: 0.5 g/cm³ ... 2.5 g/cm³; Performance: Accuracy of sensor element: ± 2 mm; Reproducibility: ≤ 1 mm; Viscosity: 0.1 mPas ... 10,000 mPas; Response time: 500 ms; Electronics: Residual ripple: ≤ 5 Vpp; Power...
Product detailsAdd to RFQ
LFV330-XXGBVXPT1900 - Sick
Features: Medium: Fluids; Measurement: Switch; Probe length: 1,900 mm; Process pressure: –1 bar ... 64 bar; Process temperature: –50 °C ... +150 °C; Fill material density: 0.5 g/cm³ ... 2.5 g/cm³; Performance: Accuracy of sensor element: ± 2 mm; Reproducibility: ≤ 1 mm; Viscosity: 0.1 mPas ... 10,000 mPas; Response time: 500 ms; Electronics: Residual ripple: ≤ 5 Vpp; Power...
Product detailsAdd to RFQ
LFV330-XXGBVXPR0100 - Sick
Features: Medium: Fluids; Measurement: Switch; Probe length: 100 mm; Process pressure: –1 bar ... 64 bar; Process temperature: –50 °C ... +150 °C; Fill material density: 0.5 g/cm³ ... 2.5 g/cm³; Performance: Accuracy of sensor element: ± 2 mm; Reproducibility: ≤ 1 mm; Viscosity: 0.1 mPas ... 10,000 mPas; Response time: 500 ms; Electronics: Power consumption: 5 mA ... 30...
Product detailsAdd to RFQ
LFV330-XXGBVXPN0180 - Sick
Features: Medium: Fluids; Measurement: Switch; Probe length: 180 mm; Process pressure: –1 bar ... 64 bar; Process temperature: –50 °C ... +150 °C; Fill material density: 0.5 g/cm³ ... 2.5 g/cm³; Performance: Accuracy of sensor element: ± 2 mm; Reproducibility: ≤ 1 mm; Viscosity: 0.1 mPas ... 10,000 mPas; Response time: 500 ms; Electronics: Residual ripple: ≤ 5 Vpp; Power...
Product detailsAdd to RFQ
LFV330-XXGBVXPN0100 - Sick
Features: Medium: Fluids; Measurement: Switch; Probe length: 100 mm; Process pressure: –1 bar ... 64 bar; Process temperature: –50 °C ... +150 °C; Fill material density: 0.5 g/cm³ ... 2.5 g/cm³; Performance: Accuracy of sensor element: ± 2 mm; Reproducibility: ≤ 1 mm; Viscosity: 0.1 mPas ... 10,000 mPas; Response time: 500 ms; Electronics: Residual ripple: ≤ 5 Vpp; Power...
Product detailsAdd to RFQ
LFV330-XXGBVXPR0800 - Sick
Features: Medium: Fluids; Measurement: Switch; Probe length: 800 mm; Process pressure: –1 bar ... 64 bar; Process temperature: –50 °C ... +150 °C; Fill material density: 0.5 g/cm³ ... 2.5 g/cm³; Performance: Accuracy of sensor element: ± 2 mm; Reproducibility: ≤ 1 mm; Viscosity: 0.1 mPas ... 10,000 mPas; Response time: 500 ms; Electronics: Power consumption: 5 mA ... 30...
Product detailsAdd to RFQ
LFV330-XXGBVXPR2000 - Sick
Features: Medium: Fluids; Measurement: Switch; Probe length: 2,000 mm; Process pressure: –1 bar ... 64 bar; Process temperature: –50 °C ... +150 °C; Fill material density: 0.5 g/cm³ ... 2.5 g/cm³; Performance: Accuracy of sensor element: ± 2 mm; Reproducibility: ≤ 1 mm; Viscosity: 0.1 mPas ... 10,000 mPas; Response time: 500 ms; Electronics: Power consumption: 5 mA ... 30...
Product detailsAdd to RFQ
LFV330-XXGBVXPR0118 - Sick
Features: Medium: Fluids; Measurement: Switch; Probe length: 118 mm; Process pressure: –1 bar ... 64 bar; Process temperature: –50 °C ... +150 °C; Fill material density: 0.5 g/cm³ ... 2.5 g/cm³; Performance: Accuracy of sensor element: ± 2 mm; Reproducibility: ≤ 1 mm; Viscosity: 0.1 mPas ... 10,000 mPas; Response time: 500 ms; Electronics: Power consumption: 5 mA ... 30...