[siemens_summary]
[catalog_children]
[catalog_search_products]
Linear encoders

Linear encoders

Items 13 - 24 of 233 from SICK ⍾ Last modified Sep 4, 2025

Linear encoders ⍾ Page 2

Product detailsAdd to RFQ
MAX48N-32V20MC0400 - Sick
Safety-related parameters: MTTFd: mean time to dangerous failure: 69 years (EN ISO 13849-1) 1) 2); Performance: Measured values: Positioning; Measuring rangePosition (F.S.)0 mm ... 400 mm 1): Measuring range; Unusable rangeNull zone30 mmDamping zone63 mm: Unusable range; Switch-on time: < 250 ms; Measuring frequency (internal): 2 ms; Transmission rate (cycle time): Constant analog output signal; Setpoint toleranceZero point and F.S.≤...
Product detailsAdd to RFQ
MAX48N-32V20MC0350 - Sick
Safety-related parameters: MTTFd: mean time to dangerous failure: 69 years (EN ISO 13849-1) 1) 2); Performance: Measured values: Positioning; Measuring rangePosition (F.S.)0 mm ... 300 mm 1): Measuring range; Unusable rangeNull zone30 mmDamping zone63 mm: Unusable range; Switch-on time: < 250 ms; Measuring frequency (internal): 2 ms; Transmission rate (cycle time): Constant analog output signal; Setpoint toleranceZero point and F.S.≤...
Product detailsAdd to RFQ
MAX48N-32V20K20365 - Sick
Safety-related parameters: MTTFd: mean time to dangerous failure: 69 years (EN ISO 13849-1) 1) 2); Performance: Measured values: Positioning; Measuring rangePosition (F.S.)0 mm ... 365 mm 1): Measuring range; Unusable rangeNull zone30 mmDamping zone63 mm: Unusable range; Switch-on time: < 250 ms; Measuring frequency (internal): 2 ms; Transmission rate (cycle time): Constant analog output signal; Setpoint toleranceZero point and F.S.≤...
Product detailsAdd to RFQ
MAX48N-32V20K60400 - Sick
Safety-related parameters: MTTFd: mean time to dangerous failure: 69 years (EN ISO 13849-1) 1) 2); Performance: Measured values: Positioning; Measuring rangePosition (F.S.)0 mm ... 400 mm 1): Measuring range; Unusable rangeNull zone30 mmDamping zone63 mm: Unusable range; Switch-on time: < 250 ms; Measuring frequency (internal): 2 ms; Transmission rate (cycle time): Constant analog output signal; Setpoint toleranceZero point and F.S.≤...
Product detailsAdd to RFQ
MAX48N-32V20K60767 - Sick
Safety-related parameters: MTTFd: mean time to dangerous failure: 69 years (EN ISO 13849-1) 1) 2); Performance: Measured values: Positioning; Measuring rangePosition (F.S.)0 mm ... 767 mm 1): Measuring range; Unusable rangeNull zone30 mmDamping zone63 mm: Unusable range; Switch-on time: < 250 ms; Measuring frequency (internal): 2 ms; Transmission rate (cycle time): Constant analog output signal; Setpoint toleranceZero point and F.S.≤...
Product detailsAdd to RFQ
MAX48N-32JFDCC0300 - Sick
Safety-related parameters: MTTFd: mean time to dangerous failure: 69 years (EN ISO 13849-1) 1) 2); Performance: Measured values: Positioning, speed; Measuring rangePosition (F.S.)0 mm ... 300 mm 1): Measuring range; Unusable rangeNull zone30 mmDamping zone63 mm: Unusable range; Switch-on time: < 250 ms; Measuring frequency (internal): 1 ms; Transmission rate (cycle time): 20 ms; Setpoint toleranceZero point and F.S.≤ ±...
Product detailsAdd to RFQ
MAX48N-32JFDCC1290 - Sick
Safety-related parameters: MTTFd: mean time to dangerous failure: 69 years (EN ISO 13849-1) 1) 2); Performance: Measured values: Positioning, speed; Measuring rangePosition (F.S.)0 mm ... 1,290 mm 1): Measuring range; Unusable rangeNull zone30 mmDamping zone63 mm: Unusable range; Switch-on time: < 250 ms; Measuring frequency (internal): 1 ms; Transmission rate (cycle time): 20 ms; Setpoint toleranceZero point and F.S.≤ ±...
Product detailsAdd to RFQ
MAX48N-32JC8DC0320 - Sick
Safety-related parameters: MTTFd: mean time to dangerous failure: 69 years (EN ISO 13849-1) 1) 2); Performance: Measured values: Positioning, speed; Measuring rangePosition (F.S.)0 mm ... 320 mm 1): Measuring range; Unusable rangeNull zone30 mmDamping zone63 mm: Unusable range; Switch-on time: < 250 ms; Measuring frequency (internal): 1 ms; Transmission rate (cycle time): 20 ms; Setpoint toleranceZero point and F.S.≤ ±...
Product detailsAdd to RFQ
MAX48N-32C7FCE0105 - Sick
Safety-related parameters: MTTFd: mean time to dangerous failure: 69 years (EN ISO 13849-1) 1) 2); Performance: Measured values: Positioning, speed; Measuring rangePosition (F.S.)0 mm ... 105 mm 1)Speed0 … 1,000 mm/s: Measuring range; Unusable rangeNull zone30 mmDamping zone63 mm: Unusable range; Switch-on time: < 250 ms; Measuring frequency (internal): 1 ms; Transmission rate (cycle time): CANopen (0 ... 65,535 ms),...
Product detailsAdd to RFQ
MAX48N-32E7FCE0105 - Sick
Safety-related parameters: MTTFd: mean time to dangerous failure: 69 years (EN ISO 13849-1) 1) 2); Performance: Measured values: Positioning, speed; Measuring rangePosition (F.S.)0 mm ... 105 mm 1)Speed0 … 1,000 mm/s: Measuring range; Unusable rangeNull zone30 mmDamping zone63 mm: Unusable range; Switch-on time: < 250 ms; Measuring frequency (internal): 1 ms; Transmission rate (cycle time): CANopen (0 ... 65,535 ms),...
Product detailsAdd to RFQ
MAX48N-32V10MC0200 - Sick
Safety-related parameters: MTTFd: mean time to dangerous failure: 69 years (EN ISO 13849-1) 1) 2); Performance: Measured values: Positioning; Measuring rangePosition (F.S.)0 mm ... 200 mm 1): Measuring range; Unusable rangeNull zone30 mmDamping zone63 mm: Unusable range; Switch-on time: < 250 ms; Measuring frequency (internal): 2 ms; Transmission rate (cycle time): Constant analog output signal; Setpoint toleranceZero point and F.S.≤...
Product detailsAdd to RFQ
MAX48N-32V10K20500 - Sick
Safety-related parameters: MTTFd: mean time to dangerous failure: 69 years (EN ISO 13849-1) 1) 2); Performance: Measured values: Positioning; Measuring rangePosition (F.S.)0 mm ... 500 mm 1): Measuring range; Unusable rangeNull zone30 mmDamping zone63 mm: Unusable range; Switch-on time: < 250 ms; Measuring frequency (internal): 2 ms; Transmission rate (cycle time): Constant analog output signal; Setpoint toleranceZero point and F.S.≤...