[siemens_summary]
[catalog_children]
[catalog_search_products]
Long range distance sensors

Long range distance sensors

Items 97 - 108 of 210 from SICK ⍾ Last modified Sep 3, 2025

Long range distance sensors ⍾ Page 9

Product detailsAdd to RFQ
DME4000-127 - Sick
DME4000, HIPERFACE. Measuring range: 0.15 m ... 50 m, on Diamond Grade. Data interface: HIPERFACE. Ambient temperature: Operation with heating: -40 ... 55 °C, Operation with cooling case: -40 ... 75 °C, Storage: -25 ... 75 °C.
Product detailsAdd to RFQ
DME4000-224 - Sick
DME4000, DeviceNet. Measuring range: 0.15 m ... 130 m, on Diamond Grade. Data interface: DeviceNet. Ambient temperature: Operation with heating: -40 ... 55 °C, Operation with cooling case: -40 ... 75 °C, Storage: -25 ... 75 °C.
Product detailsAdd to RFQ
DME4000-124 - Sick
DME4000, DeviceNet. Measuring range: 0.15 m ... 50 m, on Diamond Grade. Data interface: DeviceNet. Ambient temperature: Operation with heating: -40 ... 55 °C, Operation with cooling case: -40 ... 75 °C, Storage: -25 ... 75 °C.
Product detailsAdd to RFQ
DME4000-211 - Sick
DME4000, SSI. Measuring range: 0.15 m ... 130 m, on Diamond Grade. Data interface: SSI. Ambient temperature: Operation: -10 ... 55 °C, Operation with cooling case: -10 ... 75 °C, Storage: -25 ... 75 °C.
Product detailsAdd to RFQ
DME4000-213 - Sick
DME4000, RS-422. Measuring range: 0.15 m ... 130 m, on Diamond Grade. Data interface: RS-422. Ambient temperature: Operation: -10 ... 55 °C, Operation with cooling case: -10 ... 75 °C, Storage: -25 ... 75 °C.
Product detailsAdd to RFQ
DME4000-121 - Sick
DME4000, SSI. Measuring range: 0.15 m ... 50 m, on Diamond Grade. Data interface: SSI. Ambient temperature: Operation with heating: -40 ... 55 °C, Operation with cooling case: -40 ... 75 °C, Storage: -25 ... 75 °C.
Product detailsAdd to RFQ
DME4000-215 - Sick
DME4000, DeviceNet. Measuring range: 0.15 m ... 130 m, on Diamond Grade. Data interface: DeviceNet. Ambient temperature: Operation: -10 ... 55 °C, Operation with cooling case: -10 ... 75 °C, Storage: -25 ... 75 °C.
Product detailsAdd to RFQ
DME4000-119S03 - Sick
DME4000, CANopen. Measuring range: 0.15 m ... 50 m, on Diamond Grade. Data interface: CANopen. Ambient temperature: Operation: -10 ... 55 °C, Operation with cooling case: -10 ... 75 °C, Storage: -25 ... 75 °C.
Product detailsAdd to RFQ
DME4000-214 - Sick
DME4000, DeviceNet. Measuring range: 0.15 m ... 130 m, on Diamond Grade. Data interface: DeviceNet. Ambient temperature: Operation: -10 ... 55 °C, Operation with cooling case: -10 ... 75 °C, Storage: -25 ... 75 °C.
Product detailsAdd to RFQ
DME4000-212 - Sick
DME4000, Profibus. Measuring range: 0.15 m ... 130 m, on Diamond Grade. Data interface: PROFIBUS. Ambient temperature: Operation: -10 ... 55 °C, Operation with cooling case: -10 ... 75 °C, Storage: -25 ... 75 °C.
Product detailsAdd to RFQ
DME4000-211S06 - Sick
DME4000, SSI. Measuring range: 0.15 m ... 130 m, on Diamond Grade. Data interface: SSI. Ambient temperature: Operation: -10 ... 55 °C, Operation with cooling case: -10 ... 75 °C, Storage: -25 ... 75 °C.
Product detailsAdd to RFQ
DME4000-115 - Sick
DME4000, DeviceNet. Measuring range: 0.15 m ... 50 m, on Diamond Grade. Data interface: DeviceNet. Ambient temperature: Operation: -10 ... 55 °C, Operation with cooling case: -10 ... 75 °C, Storage: -25 ... 75 °C.