SICK
>
Opto-Electronic Protective Devices
>
Multiple light beam safety devices
>
M2000
>
M2000 Cascadable
[siemens_summary]
[catalog_children]
[catalog_search_products]
M2000 Cascadable
Items 13 - 24 of 47
from
SICK
⍾ Last modified Sep 4, 2025
▲
Search
M2000 Cascadable ⍾ Page 2
«
1
2
3
4
»
Product details
Add to RFQ
M20S-081A3A220 - Sick
Safety-related parameters: Type: Type 2 (IEC 61496-1); Safety integrity level: SIL1 (IEC 61508)SILCL1 (EN 62061); Category: Category 2 (EN ISO 13849); Test rate (internal test): 13 /s (EN ISO 13849) 1); Maximum demand rate: ≤ 8 min⁻¹ (EN ISO 13849) 2); Performance level: PL c (EN ISO 13849); PFHD (mean probability of a dangerous failure per hour): 6.6 x 10-9...
Product details
Add to RFQ
M20E-091A3A222 , M20S-091A3A222 - Sick
Designation: M2000 Cascadable. Number of beams: 9. Muting with: Flexi Classic, Flexi Soft. Configuration method: hard wired.
Product details
Add to RFQ
M20S-02150A221 - Sick
Safety-related parameters: Type: Type 2 (IEC 61496-1); Safety integrity level: SIL1 (IEC 61508)SILCL1 (EN 62061); Category: Category 2 (EN ISO 13849); Test rate (internal test): 13 /s (EN ISO 13849) 1); Maximum demand rate: ≤ 8 min⁻¹ (EN ISO 13849) 2); Performance level: PL c (EN ISO 13849); PFHD (mean probability of a dangerous failure per hour): 6.6 x 10-9...
Product details
Add to RFQ
M20S-03140A220 - Sick
Safety-related parameters: Type: Type 2 (IEC 61496-1); Safety integrity level: SIL1 (IEC 61508)SILCL1 (EN 62061); Category: Category 2 (EN ISO 13849); Test rate (internal test): 13 /s (EN ISO 13849) 1); Maximum demand rate: ≤ 8 min⁻¹ (EN ISO 13849) 2); Performance level: PL c (EN ISO 13849); PFHD (mean probability of a dangerous failure per hour): 6.6 x 10-9...
Product details
Add to RFQ
M20E-091A3A221 - Sick
Safety-related parameters: Type: Type 2 (IEC 61496-1); Safety integrity level: SIL1 (IEC 61508)SILCL1 (EN 62061); Category: Category 2 (EN ISO 13849); Test rate (internal test): 13 /s (EN ISO 13849) 1); Maximum demand rate: ≤ 8 min⁻¹ (EN ISO 13849) 2); Performance level: PL c (EN ISO 13849); PFHD (mean probability of a dangerous failure per hour): 6.6 x 10-9...
Product details
Add to RFQ
M20E-081A3A222 - Sick
Safety-related parameters: Type: Type 2 (IEC 61496-1); Safety integrity level: SIL1 (IEC 61508)SILCL1 (EN 62061); Category: Category 2 (EN ISO 13849); Test rate (internal test): 13 /s (EN ISO 13849) 1); Maximum demand rate: ≤ 8 min⁻¹ (EN ISO 13849) 2); Performance level: PL c (EN ISO 13849); PFHD (mean probability of a dangerous failure per hour): 6.6 x 10-9...
Product details
Add to RFQ
M20E-081A3A221 - Sick
Safety-related parameters: Type: Type 2 (IEC 61496-1); Safety integrity level: SIL1 (IEC 61508)SILCL1 (EN 62061); Category: Category 2 (EN ISO 13849); Test rate (internal test): 13 /s (EN ISO 13849) 1); Maximum demand rate: ≤ 8 min⁻¹ (EN ISO 13849) 2); Performance level: PL c (EN ISO 13849); PFHD (mean probability of a dangerous failure per hour): 6.6 x 10-9...
Product details
Add to RFQ
M20E-081A3A222 , M20S-081A3A222 - Sick
Designation: M2000 Cascadable. Number of beams: 8. Muting with: Flexi Classic, Flexi Soft. Configuration method: hard wired.
Product details
Add to RFQ
M20E-081A2A222 , M20S-081A2A222 - Sick
Designation: M2000 Cascadable. Number of beams: 8. Muting with: Flexi Classic, Flexi Soft. Configuration method: hard wired.
Product details
Add to RFQ
M20E-081A3A221 , M20S-081A3A220 - Sick
Designation: M2000 Cascadable. Number of beams: 8. Muting with: Flexi Classic, Flexi Soft. Configuration method: hard wired.
Product details
Add to RFQ
M20E-071A3A221 , M20S-071A3A220 - Sick
Designation: M2000 Cascadable. Number of beams: 7. Muting with: Flexi Classic, Flexi Soft. Configuration method: hard wired.
Product details
Add to RFQ
M20E-071A3A221 - Sick
Safety-related parameters: Type: Type 2 (IEC 61496-1); Safety integrity level: SIL1 (IEC 61508)SILCL1 (EN 62061); Category: Category 2 (EN ISO 13849); Test rate (internal test): 13 /s (EN ISO 13849) 1); Maximum demand rate: ≤ 8 min⁻¹ (EN ISO 13849) 2); Performance level: PL c (EN ISO 13849); PFHD (mean probability of a dangerous failure per hour): 6.6 x 10-9...