[siemens_summary]
[catalog_children]
[catalog_search_products]
Magnetic-inductive volumetric flow meters

Magnetic-inductive volumetric flow meters

Items 13 - 22 of 22 from IFM ⍾ Last modified Oct 1, 2025

Magnetic-inductive volumetric flow meters ⍾ Page 2

Product detailsAdd to RFQ
SM6100 - Ifm
Magnetic-inductive flow meter; Operating voltage [V] : 18...30 DC; (according to EN 50178 SELV/PELV); Min. insulation resistance [MΩ] : 100; (500 V DC); Protection class : III; Reverse polarity protection : yes; Power-on delay time [s] : 5; Inputs : counter reset; Total number of outputs : 2; Output signal : switching signal; analogue signal; pulse signal; IO-Link; (configurable); Electrical design...
Product detailsAdd to RFQ
SM6004 - Ifm
Magnetic-inductive flow meter; Operating voltage [V] : 20...30 DC; (according to EN 50178 SELV/PELV); Protection class : III; Reverse polarity protection : yes; Power-on delay time [s] : 5; Total number of outputs : 2; Output signal : analogue signal; Number of analogue outputs : 2; Analogue current output [mA] : 4...20; (scalable); Max. load [Ω] : 500; Overload protection :...
Product detailsAdd to RFQ
SM6001 - Ifm
Magnetic-inductive flow meter; Operating voltage [V] : 18...30 DC; (according to EN 50178 SELV/PELV); Min. insulation resistance [MΩ] : 100; (500 V DC); Protection class : III; Reverse polarity protection : yes; Power-on delay time [s] : 5; Inputs : counter reset; Total number of outputs : 2; Output signal : switching signal; analogue signal; pulse signal; IO-Link; (configurable); Electrical design...
Product detailsAdd to RFQ
SM7050 - Ifm
Magnetic-inductive flow meter; Operating voltage [V] : 18...30 DC; (according to EN 50178 SELV/PELV); Protection class : III; Reverse polarity protection : yes; Power-on delay time [s] : 5; Total number of outputs : 1; Output signal : analogue signal; IO-Link; (configurable); Permanent current rating of switching output DC [mA] : 250; Number of analogue outputs : 1; Analogue current output...
Product detailsAdd to RFQ
SM7100 - Ifm
Magnetic-inductive flow meter; Operating voltage [V] : 18...30 DC; (according to EN 50178 SELV/PELV); Protection class : III; Reverse polarity protection : yes; Power-on delay time [s] : 5; Inputs : counter reset; Total number of outputs : 2; Output signal : switching signal; analogue signal; pulse signal; IO-Link; (configurable); Electrical design : PNP/NPN; Number of digital outputs : 2; Output...
Product detailsAdd to RFQ
SM7004 - Ifm
Magnetic-inductive flow meter; Operating voltage [V] : 20...30 DC; (according to EN 50178 SELV/PELV); Protection class : III; Reverse polarity protection : yes; Power-on delay time [s] : 5; Total number of outputs : 2; Output signal : analogue signal; Number of analogue outputs : 2; Analogue current output [mA] : 4...20; (scalable); Max. load [Ω] : 500; Overload protection :...
Product detailsAdd to RFQ
SM7001 - Ifm
Magnetic-inductive flow meter; Operating voltage [V] : 18...30 DC; (according to EN 50178 SELV/PELV); Protection class : III; Reverse polarity protection : yes; Power-on delay time [s] : 5; Inputs : counter reset; Total number of outputs : 2; Output signal : switching signal; analogue signal; pulse signal; IO-Link; (configurable); Electrical design : PNP/NPN; Number of digital outputs : 2; Output...
Product detailsAdd to RFQ
SM7000 - Ifm
Magnetic-inductive flow meter; Operating voltage [V] : 18...30 DC; (according to EN 50178 SELV/PELV); Protection class : III; Reverse polarity protection : yes; Power-on delay time [s] : 5; Inputs : counter reset; Total number of outputs : 2; Output signal : switching signal; analogue signal; pulse signal; IO-Link; (configurable); Electrical design : PNP/NPN; Number of digital outputs : 2; Output...
Product detailsAdd to RFQ
SM0505 - Ifm
Magnetic-inductive flow meter; Operating voltage [V] : 18...30 DC; (according to EN 50178 SELV/PELV); Min. insulation resistance [MΩ] : 100; (500 V DC); Protection class : III; Reverse polarity protection : yes; Power-on delay time [s] : 5; Inputs : counter reset; Total number of outputs : 2; Output signal : switching signal; analogue signal; pulse signal; (configurable); Electrical design :...
Product detailsAdd to RFQ
SM2004 - Ifm
Magnetic-inductive flow meter; Operating voltage [V] : 18...32 DC; (according to EN 50178 SELV/PELV); Protection class : III; Reverse polarity protection : yes; Power-on delay time [s] : 5; Total number of outputs : 2; Output signal : analogue signal; Number of analogue outputs : 2; Analogue current output [mA] : 4...20; (≤ 22 mA; scalable); Max. load [Ω] : 500;...