[siemens_summary]
[catalog_children]
[catalog_search_products]

MAX48 ⍾ Page 14

Product detailsAdd to RFQ
MAX48N-11V10K11100 - Sick
Safety-related parameters: MTTFd: mean time to dangerous failure: 69 years (EN ISO 13849-1) 1) 2); Performance: Measured values: Positioning; Measuring rangePosition (F.S.)0 mm ... 1,100 mm 1): Measuring range; Unusable rangeNull zone30 mmDamping zone30 mm: Unusable range; Switch-on time: < 250 ms; Measuring frequency (internal): 2 ms; Transmission rate (cycle time): Constant analog output signal; Setpoint toleranceZero point and F.S.≤...
Product detailsAdd to RFQ
MAX48N-11V10K12500 - Sick
Safety-related parameters: MTTFd: mean time to dangerous failure: 69 years (EN ISO 13849-1) 1) 2); Performance: Measured values: Positioning; Measuring rangePosition (F.S.)0 mm ... 2,500 mm 1): Measuring range; Unusable rangeNull zone30 mmDamping zone30 mm: Unusable range; Switch-on time: < 250 ms; Measuring frequency (internal): 2 ms; Transmission rate (cycle time): Constant analog output signal; Setpoint toleranceZero point and F.S.≤...
Product detailsAdd to RFQ
MAX48N-12A10AA0500 - Sick
Safety-related parameters: MTTFd: mean time to dangerous failure: 69 years (EN ISO 13849-1) 1) 2); Performance: Measured values: Positioning; Measuring rangePosition (F.S.)0 mm ... 500 mm 1): Measuring range; Unusable rangeNull zone30 mmDamping zone30 mm: Unusable range; Switch-on time: < 250 ms; Measuring frequency (internal): 2 ms; Transmission rate (cycle time): Constant analog output signal; Setpoint toleranceZero point and F.S.≤...
Product detailsAdd to RFQ
MAX48N-11V20AA0500 - Sick
Safety-related parameters: MTTFd: mean time to dangerous failure: 69 years (EN ISO 13849-1) 1) 2); Performance: Measured values: Positioning; Measuring rangePosition (F.S.)0 mm ... 500 mm 1): Measuring range; Unusable rangeNull zone30 mmDamping zone30 mm: Unusable range; Switch-on time: < 250 ms; Measuring frequency (internal): 2 ms; Transmission rate (cycle time): Constant analog output signal; Setpoint toleranceZero point and F.S.≤...
Product detailsAdd to RFQ
MAX48N-11V20AC0500 - Sick
Safety-related parameters: MTTFd: mean time to dangerous failure: 69 years (EN ISO 13849-1) 1) 2); Performance: Measured values: Positioning; Measuring rangePosition (F.S.)0 mm ... 500 mm 1): Measuring range; Unusable rangeNull zone30 mmDamping zone30 mm: Unusable range; Switch-on time: < 250 ms; Measuring frequency (internal): 2 ms; Transmission rate (cycle time): Constant analog output signal; Setpoint toleranceZero point and F.S.≤...
Product detailsAdd to RFQ
MAX48N-11V10K20300 - Sick
Safety-related parameters: MTTFd: mean time to dangerous failure: 69 years (EN ISO 13849-1) 1) 2); Performance: Measured values: Positioning; Measuring rangePosition (F.S.)0 mm ... 300 mm 1): Measuring range; Unusable rangeNull zone30 mmDamping zone30 mm: Unusable range; Switch-on time: < 250 ms; Measuring frequency (internal): 2 ms; Transmission rate (cycle time): Constant analog output signal; Setpoint toleranceZero point and F.S.≤...
Product detailsAdd to RFQ
MAX48N-11V10K30300 - Sick
Safety-related parameters: MTTFd: mean time to dangerous failure: 69 years (EN ISO 13849-1) 1) 2); Performance: Measured values: Positioning; Measuring rangePosition (F.S.)0 mm ... 300 mm 1): Measuring range; Unusable rangeNull zone30 mmDamping zone30 mm: Unusable range; Switch-on time: < 250 ms; Measuring frequency (internal): 2 ms; Transmission rate (cycle time): Constant analog output signal; Setpoint toleranceZero point and F.S.≤...
Product detailsAdd to RFQ
MAX48N-11V20K10500 - Sick
Safety-related parameters: MTTFd: mean time to dangerous failure: 69 years (EN ISO 13849-1) 1) 2); Performance: Measured values: Positioning; Measuring rangePosition (F.S.)0 mm ... 500 mm 1): Measuring range; Unusable rangeNull zone30 mmDamping zone30 mm: Unusable range; Switch-on time: < 250 ms; Measuring frequency (internal): 2 ms; Transmission rate (cycle time): Constant analog output signal; Setpoint toleranceZero point and F.S.≤...
Product detailsAdd to RFQ
MAX48N-11V10AC0100 - Sick
Safety-related parameters: MTTFd: mean time to dangerous failure: 69 years (EN ISO 13849-1) 1) 2); Performance: Measured values: Positioning; Measuring rangePosition (F.S.)0 mm ... 100 mm 1): Measuring range; Unusable rangeNull zone30 mmDamping zone30 mm: Unusable range; Switch-on time: < 250 ms; Measuring frequency (internal): 2 ms; Transmission rate (cycle time): Constant analog output signal; Setpoint toleranceZero point and F.S.≤...
Product detailsAdd to RFQ
MAX48N-11V10BA0400 - Sick
Safety-related parameters: MTTFd: mean time to dangerous failure: 69 years (EN ISO 13849-1) 1) 2); Performance: Measured values: Positioning; Measuring rangePosition (F.S.)0 mm ... 400 mm 1): Measuring range; Unusable rangeNull zone30 mmDamping zone30 mm: Unusable range; Switch-on time: < 250 ms; Measuring frequency (internal): 2 ms; Transmission rate (cycle time): Constant analog output signal; Setpoint toleranceZero point and F.S.≤...
Product detailsAdd to RFQ
MAX48N-11V10AE1000 - Sick
Safety-related parameters: MTTFd: mean time to dangerous failure: 69 years (EN ISO 13849-1) 1) 2); Performance: Measured values: Positioning; Measuring rangePosition (F.S.)0 mm ... 1,000 mm 1): Measuring range; Unusable rangeNull zone30 mmDamping zone30 mm: Unusable range; Switch-on time: < 250 ms; Measuring frequency (internal): 2 ms; Transmission rate (cycle time): Constant analog output signal; Setpoint toleranceZero point and F.S.≤...