[siemens_summary]
[catalog_children]
[catalog_search_products]
MAX48N-12 / MAX48

MAX48N-12 / MAX48

Items 1 - 12 of 93 from SICK ⍾ Last modified Sep 4, 2025

MAX48N-12 / MAX48 ⍾ Page 1

Product detailsAdd to RFQ
MAX48N-12V30BC0500 - Sick
Safety-related parameters: MTTFd: mean time to dangerous failure: 69 years (EN ISO 13849-1) 1) 2); Performance: Measured values: Positioning; Measuring rangePosition (F.S.)0 mm ... 500 mm 1): Measuring range; Unusable rangeNull zone30 mmDamping zone30 mm: Unusable range; Switch-on time: < 250 ms; Measuring frequency (internal): 2 ms; Transmission rate (cycle time): Constant analog output signal; Setpoint toleranceZero point and F.S.≤...
Product detailsAdd to RFQ
MAX48N-12V30BM0300 - Sick
Safety-related parameters: MTTFd: mean time to dangerous failure: 69 years (EN ISO 13849-1) 1) 2); Performance: Measured values: Positioning; Measuring rangePosition (F.S.)0 mm ... 300 mm 1): Measuring range; Unusable rangeNull zone30 mmDamping zone30 mm: Unusable range; Switch-on time: < 250 ms; Measuring frequency (internal): 2 ms; Transmission rate (cycle time): Constant analog output signal; Setpoint toleranceZero point and F.S.≤...
Product detailsAdd to RFQ
MAX48N-12V30AE1565 - Sick
Safety-related parameters: MTTFd: mean time to dangerous failure: 69 years (EN ISO 13849-1) 1) 2); Performance: Measured values: Positioning; Measuring rangePosition (F.S.)0 mm ... 1,565 mm 1): Measuring range; Unusable rangeNull zone30 mmDamping zone30 mm: Unusable range; Switch-on time: < 250 ms; Measuring frequency (internal): 2 ms; Transmission rate (cycle time): Constant analog output signal; Setpoint toleranceZero point and F.S.≤...
Product detailsAdd to RFQ
MAX48N-12V30ME0500 - Sick
Safety-related parameters: MTTFd: mean time to dangerous failure: 69 years (EN ISO 13849-1) 1) 2); Performance: Measured values: Positioning; Measuring rangePosition (F.S.)0 mm ... 500 mm 1): Measuring range; Unusable rangeNull zone30 mmDamping zone30 mm: Unusable range; Switch-on time: < 250 ms; Measuring frequency (internal): 2 ms; Transmission rate (cycle time): Constant analog output signal; Setpoint toleranceZero point and F.S.≤...
Product detailsAdd to RFQ
MAX48N-12V30K10500 - Sick
Safety-related parameters: MTTFd: mean time to dangerous failure: 69 years (EN ISO 13849-1) 1) 2); Performance: Measured values: Positioning; Measuring rangePosition (F.S.)0 mm ... 500 mm 1): Measuring range; Unusable rangeNull zone30 mmDamping zone30 mm: Unusable range; Switch-on time: < 250 ms; Measuring frequency (internal): 2 ms; Transmission rate (cycle time): Constant analog output signal; Setpoint toleranceZero point and F.S.≤...
Product detailsAdd to RFQ
MAX48N-12V30AM0250 - Sick
Safety-related parameters: MTTFd: mean time to dangerous failure: 69 years (EN ISO 13849-1) 1) 2); Performance: Measured values: Positioning; Measuring rangePosition (F.S.)0 mm ... 250 mm 1): Measuring range; Unusable rangeNull zone30 mmDamping zone30 mm: Unusable range; Switch-on time: < 250 ms; Measuring frequency (internal): 2 ms; Transmission rate (cycle time): Constant analog output signal; Setpoint toleranceZero point and F.S.≤...
Product detailsAdd to RFQ
MAX48N-12V30K91100 - Sick
Safety-related parameters: MTTFd: mean time to dangerous failure: 69 years (EN ISO 13849-1) 1) 2); Performance: Measured values: Positioning; Measuring rangePosition (F.S.)0 mm ... 1,100 mm 1): Measuring range; Unusable rangeNull zone30 mmDamping zone30 mm: Unusable range; Switch-on time: < 250 ms; Measuring frequency (internal): 2 ms; Transmission rate (cycle time): Constant analog output signal; Setpoint toleranceZero point and F.S.≤...
Product detailsAdd to RFQ
MAX48N-12V30K60110 - Sick
Safety-related parameters: MTTFd: mean time to dangerous failure: 69 years (EN ISO 13849-1) 1) 2); Performance: Measured values: Positioning; Measuring rangePosition (F.S.)0 mm ... 110 mm 1): Measuring range; Unusable rangeNull zone30 mmDamping zone30 mm: Unusable range; Switch-on time: < 250 ms; Measuring frequency (internal): 2 ms; Transmission rate (cycle time): Constant analog output signal; Setpoint toleranceZero point and F.S.≤...
Product detailsAdd to RFQ
MAX48N-12V30AE1070 - Sick
Safety-related parameters: MTTFd: mean time to dangerous failure: 69 years (EN ISO 13849-1) 1) 2); Performance: Measured values: Positioning; Measuring rangePosition (F.S.)0 mm ... 1,070 mm 1): Measuring range; Unusable rangeNull zone30 mmDamping zone30 mm: Unusable range; Switch-on time: < 250 ms; Measuring frequency (internal): 2 ms; Transmission rate (cycle time): Constant analog output signal; Setpoint toleranceZero point and F.S.≤...
Product detailsAdd to RFQ
MAX48N-12V30AC0190 - Sick
Safety-related parameters: MTTFd: mean time to dangerous failure: 69 years (EN ISO 13849-1) 1) 2); Performance: Measured values: Positioning; Measuring rangePosition (F.S.)0 mm ... 190 mm 1): Measuring range; Unusable rangeNull zone30 mmDamping zone30 mm: Unusable range; Switch-on time: < 250 ms; Measuring frequency (internal): 2 ms; Transmission rate (cycle time): Constant analog output signal; Setpoint toleranceZero point and F.S.≤...
Product detailsAdd to RFQ
MAX48N-12V30AA0500 - Sick
Safety-related parameters: MTTFd: mean time to dangerous failure: 69 years (EN ISO 13849-1) 1) 2); Performance: Measured values: Positioning; Measuring rangePosition (F.S.)0 mm ... 500 mm 1): Measuring range; Unusable rangeNull zone30 mmDamping zone30 mm: Unusable range; Switch-on time: < 250 ms; Measuring frequency (internal): 2 ms; Transmission rate (cycle time): Constant analog output signal; Setpoint toleranceZero point and F.S.≤...
Product detailsAdd to RFQ
MAX48N-12V20BC0500 - Sick
Safety-related parameters: MTTFd: mean time to dangerous failure: 69 years (EN ISO 13849-1) 1) 2); Performance: Measured values: Positioning; Measuring rangePosition (F.S.)0 mm ... 500 mm 1): Measuring range; Unusable rangeNull zone30 mmDamping zone30 mm: Unusable range; Switch-on time: < 250 ms; Measuring frequency (internal): 2 ms; Transmission rate (cycle time): Constant analog output signal; Setpoint toleranceZero point and F.S.≤...