[siemens_summary]
[catalog_children]
[catalog_search_products]
Measuring wheel encoders

Measuring wheel encoders

Items 1 - 12 of 179 from SICK ⍾ Last modified Sep 3, 2025

Measuring wheel encoders ⍾ Page 1

Product detailsAdd to RFQ
DUV60E-D4KMHADA - Sick
Performance: Linear resolution: 0.125 mm/pulse to 304.8 mm/pulse (type-dependent); Pulses per revolution: 1 ... 1500 1); Measuring step: 90° electric/pulses per revolution; Measuring increment (resolution in mm/pulse): / pulses per revolution; Measuring step deviation: ± 18°, / pulses per revolution; Error limits: Measuring step deviation x 3; Duty cycle: 0.5 ± 5 %; Initialization time: < 5 ms 2); Interfaces:...
Product detailsAdd to RFQ
DUV60E-D4KKHBGA - Sick
Performance: Linear resolution: 0.125 mm/pulse to 304.8 mm/pulse (type-dependent); Pulses per revolution: 1 ... 48 1); Measuring step: 90° electric/pulses per revolution; Measuring increment (resolution in mm/pulse): / pulses per revolution; Measuring step deviation: ± 18°, / pulses per revolution; Error limits: Measuring step deviation x 3; Duty cycle: 0.5 ± 5 %; Initialization time: < 5 ms 2); Interfaces:...
Product detailsAdd to RFQ
DUV60E-D4KKHADA - Sick
Performance: Linear resolution: 0.125 mm/pulse to 304.8 mm/pulse (type-dependent); Pulses per revolution: 1 ... 1500 1); Measuring step: 90° electric/pulses per revolution; Measuring increment (resolution in mm/pulse): / pulses per revolution; Measuring step deviation: ± 18°, / pulses per revolution; Error limits: Measuring step deviation x 3; Duty cycle: 0.5 ± 5 %; Initialization time: < 5 ms 2); Interfaces:...
Product detailsAdd to RFQ
DUV60E-D4KMGADA - Sick
Performance: Linear resolution: 0.125 mm/pulse to 304.8 mm/pulse (type-dependent); Pulses per revolution: 1 ... 1500 1); Measuring step: 90° electric/pulses per revolution; Measuring increment (resolution in mm/pulse): / pulses per revolution; Measuring step deviation: ± 18°, / pulses per revolution; Error limits: Measuring step deviation x 3; Duty cycle: 0.5 ± 5 %; Initialization time: < 5 ms 2); Interfaces:...
Product detailsAdd to RFQ
DUV60E-D4KFWDGB - Sick
Performance: Linear resolution: 0.125 mm/pulse to 304.8 mm/pulse (type-dependent); Pulses per revolution: 1 ... 48 1); Measuring step: 90° electric/pulses per revolution; Measuring increment (resolution in mm/pulse): / pulses per revolution; Measuring step deviation: ± 18°, / pulses per revolution; Error limits: Measuring step deviation x 3; Duty cycle: 0.5 ± 5 %; Initialization time: < 5 ms 2); Interfaces:...
Product detailsAdd to RFQ
DUV60E-D4KZHAZAS01 - Sick
Features: Special device: ✔; Specialty: MS 6-pin connector at the end of a 1.5 m cable, DIP switches pre-set to HTL output; Standard reference device: DUV60E-D4KKHADA, 1085779; Performance: Linear resolution: 0.125 mm/pulse to 304.8 mm/pulse (type-dependent); Pulses per revolution: 1 ... 1500 1); Measuring step: 90° electric/pulses per revolution; Measuring increment (resolution in mm/pulse): / pulses per revolution; Measuring step...
Product detailsAdd to RFQ
DUV60E-Z4KZWAZAS04 - Sick
Features: Special device: ✔; Specialty: MS 6-pin connector at the end of a 500 mm cable, DIP switches pre-set to HTL output; Standard reference device: DUV60E-D4KKWADA, 1090501; Performance: Linear resolution: 0.125 mm/pulse to 304.8 mm/pulse (type-dependent); Pulses per revolution: 1 ... 1500 1); Measuring step: 90° electric/pulses per revolution; Measuring increment (resolution in mm/pulse): / pulses per revolution; Measuring step...
Product detailsAdd to RFQ
DUV60E-Z4KZWZZAS05 - Sick
Features: Special device: ✔; Specialty: MS 3-pin connector at the end of a 500 mm cable, DIP switches pre-set to HTL output; Standard reference device: DUV60E-D4KKWADA, 1090501; Performance: Linear resolution: 0.125 mm/pulse to 304.8 mm/pulse (type-dependent); Pulses per revolution: 1 ... 1500 1); Measuring step: 90° electric/pulses per revolution; Measuring increment (resolution in mm/pulse): / pulses per revolution; Measuring step...
Product detailsAdd to RFQ
DUV60E-D4KFWDEB - Sick
Performance: Linear resolution: 0.125 mm/pulse to 304.8 mm/pulse (type-dependent); Pulses per revolution: 1 ... 240 1); Measuring step: 90° electric/pulses per revolution; Measuring increment (resolution in mm/pulse): / pulses per revolution; Measuring step deviation: ± 18°, / pulses per revolution; Error limits: Measuring step deviation x 3; Duty cycle: 0.5 ± 5 %; Initialization time: < 5 ms 2); Interfaces:...
Product detailsAdd to RFQ
DUV60E-D4KFJCGB - Sick
Performance: Linear resolution: 0.125 mm/pulse to 304.8 mm/pulse (type-dependent); Pulses per revolution: 1 ... 48 1); Measuring step: 90° electric/pulses per revolution; Measuring increment (resolution in mm/pulse): / pulses per revolution; Measuring step deviation: ± 18°, / pulses per revolution; Error limits: Measuring step deviation x 3; Duty cycle: 0.5 ± 5 %; Initialization time: < 5 ms 2); Interfaces:...
Product detailsAdd to RFQ
DUV60E-D4KFKCDB - Sick
Performance: Linear resolution: 0.125 mm/pulse to 304.8 mm/pulse (type-dependent); Pulses per revolution: 1 ... 1500 1); Measuring step: 90° electric/pulses per revolution; Measuring increment (resolution in mm/pulse): / pulses per revolution; Measuring step deviation: ± 18°, / pulses per revolution; Error limits: Measuring step deviation x 3; Duty cycle: 0.5 ± 5 %; Initialization time: < 5 ms 2); Interfaces:...
Product detailsAdd to RFQ
DUV60E-D4KFKAAA - Sick
Performance: Linear resolution: 0.125 mm/pulse to 304.8 mm/pulse (type-dependent); Pulses per revolution: 1 ... 2400 1); Measuring step: 90° electric/pulses per revolution; Measuring increment (resolution in mm/pulse): / pulses per revolution; Measuring step deviation: ± 18°, / pulses per revolution; Error limits: Measuring step deviation x 3; Duty cycle: 0.5 ± 5 %; Initialization time: < 5 ms 2); Interfaces:...