[siemens_summary]
[catalog_children]
[catalog_search_products]
Measuring wheel encoders

Measuring wheel encoders

Items 109 - 120 of 179 from SICK ⍾ Last modified Sep 3, 2025

Measuring wheel encoders ⍾ Page 10

Product detailsAdd to RFQ
DBV50E-22RKB2000 - Sick
Performance: Pulses per revolution: 2,000; Resolution in pulses/mm: 10; Measuring increment (resolution in mm/pulse): 0.1, ± 18° / pulses per revolution; Measuring step deviation: ± 18° / pulses per revolution; Error limits: ± 4 mm/m, subject to the measuring wheel (wheel + surface); Duty cycle: ≤ 0.5 ± 5 %; Initialization time: 1.4 million cycles 4); Mounting position relative to...
Product detailsAdd to RFQ
DBV50E-22RMA1000 - Sick
Performance: Pulses per revolution: 1,000; Resolution in pulses/mm: 5; Measuring increment (resolution in mm/pulse): 0.2, ± 18° / pulses per revolution; Measuring step deviation: ± 18° / pulses per revolution; Error limits: ± 4 mm/m, subject to the measuring wheel (wheel + surface); Duty cycle: ≤ 0.5 ± 5 %; Initialization time: 1.4 million cycles 4); Mounting position relative to...
Product detailsAdd to RFQ
DBV50E-22RKA2000 - Sick
Performance: Pulses per revolution: 2,000; Resolution in pulses/mm: 10; Measuring increment (resolution in mm/pulse): 0.1, ± 18° / pulses per revolution; Measuring step deviation: ± 18° / pulses per revolution; Error limits: ± 4 mm/m, subject to the measuring wheel (wheel + surface); Duty cycle: ≤ 0.5 ± 5 %; Initialization time: 1.4 million cycles 4); Mounting position relative to...
Product detailsAdd to RFQ
DBV50E-22GPB0200 - Sick
Performance: Pulses per revolution: 200; Resolution in pulses/mm: 1; Measuring increment (resolution in mm/pulse): 1, ± 18° / pulses per revolution; Measuring step deviation: ± 18° / pulses per revolution; Error limits: ± 4 mm/m, subject to the measuring wheel (wheel + surface); Duty cycle: ≤ 0.5 ± 5 %; Initialization time: 1.4 million cycles 4); Mounting position relative to...
Product detailsAdd to RFQ
DBV50E-22RNA2500 - Sick
Performance: Pulses per revolution: 2,500; Resolution in pulses/mm: 12.5; Measuring increment (resolution in mm/pulse): 0.08, ± 18° / pulses per revolution; Measuring step deviation: ± 18° / pulses per revolution; Error limits: ± 4 mm/m, subject to the measuring wheel (wheel + surface); Duty cycle: ≤ 0.5 ± 5 %; Initialization time: 1.4 million cycles 4); Mounting position relative to...
Product detailsAdd to RFQ
DBV50E-22RNB0020 - Sick
Performance: Pulses per revolution: 20; Resolution in pulses/mm: 0.01; Measuring increment (resolution in mm/pulse): 10, ± 18° / pulses per revolution; Measuring step deviation: ± 18° / pulses per revolution; Error limits: ± 4 mm/m, subject to the measuring wheel (wheel + surface); Duty cycle: ≤ 0.5 ± 5 %; Initialization time: 1.4 million cycles 4); Mounting position relative to...
Product detailsAdd to RFQ
DBV50E-22RMA2000 - Sick
Performance: Pulses per revolution: 2,000; Resolution in pulses/mm: 10; Measuring increment (resolution in mm/pulse): 0.1, ± 18° / pulses per revolution; Measuring step deviation: ± 18° / pulses per revolution; Error limits: ± 4 mm/m, subject to the measuring wheel (wheel + surface); Duty cycle: ≤ 0.5 ± 5 %; Initialization time: 1.4 million cycles 4); Mounting position relative to...
Product detailsAdd to RFQ
DBV50E-22RKA2500 - Sick
Performance: Pulses per revolution: 2,500; Resolution in pulses/mm: 12.5; Measuring increment (resolution in mm/pulse): 0.08, ± 18° / pulses per revolution; Measuring step deviation: ± 18° / pulses per revolution; Error limits: ± 4 mm/m, subject to the measuring wheel (wheel + surface); Duty cycle: ≤ 0.5 ± 5 %; Initialization time: 1.4 million cycles 4); Mounting position relative to...
Product detailsAdd to RFQ
DBV50E-22GKB2000 - Sick
Performance: Pulses per revolution: 2,000; Resolution in pulses/mm: 10; Measuring increment (resolution in mm/pulse): 0.1, ± 18° / pulses per revolution; Measuring step deviation: ± 18° / pulses per revolution; Error limits: ± 4 mm/m, subject to the measuring wheel (wheel + surface); Duty cycle: ≤ 0.5 ± 5 %; Initialization time: 1.4 million cycles 4); Mounting position relative to...
Product detailsAdd to RFQ
DBV50E-22GKB0200 - Sick
Performance: Pulses per revolution: 200; Resolution in pulses/mm: 1; Measuring increment (resolution in mm/pulse): 1, ± 18° / pulses per revolution; Measuring step deviation: ± 18° / pulses per revolution; Error limits: ± 4 mm/m, subject to the measuring wheel (wheel + surface); Duty cycle: ≤ 0.5 ± 5 %; Initialization time: 1.4 million cycles 4); Mounting position relative to...
Product detailsAdd to RFQ
DBV50E-22GKA2000 - Sick
Performance: Pulses per revolution: 2,000; Resolution in pulses/mm: 10; Measuring increment (resolution in mm/pulse): 0.1, ± 18° / pulses per revolution; Measuring step deviation: ± 18° / pulses per revolution; Error limits: ± 4 mm/m, subject to the measuring wheel (wheel + surface); Duty cycle: ≤ 0.5 ± 5 %; Initialization time: 1.4 million cycles 4); Mounting position relative to...
Product detailsAdd to RFQ
DBV50E-22RMA2500 - Sick
Performance: Pulses per revolution: 2,500; Resolution in pulses/mm: 12.5; Measuring increment (resolution in mm/pulse): 0.08, ± 18° / pulses per revolution; Measuring step deviation: ± 18° / pulses per revolution; Error limits: ± 4 mm/m, subject to the measuring wheel (wheel + surface); Duty cycle: ≤ 0.5 ± 5 %; Initialization time: 1.4 million cycles 4); Mounting position relative to...