[siemens_summary]
[catalog_children]
[catalog_search_products]
Measuring wheel encoders

Measuring wheel encoders

Items 121 - 132 of 179 from SICK ⍾ Last modified Sep 3, 2025

Measuring wheel encoders ⍾ Page 11

Product detailsAdd to RFQ
DBV50E-22GNA1000 - Sick
Performance: Pulses per revolution: 1,000; Resolution in pulses/mm: 5; Measuring increment (resolution in mm/pulse): 0.2, ± 18° / pulses per revolution; Measuring step deviation: ± 18° / pulses per revolution; Error limits: ± 4 mm/m, subject to the measuring wheel (wheel + surface); Duty cycle: ≤ 0.5 ± 5 %; Initialization time: 1.4 million cycles 4); Mounting position relative to...
Product detailsAdd to RFQ
DBV50E-22GMA0010 - Sick
Performance: Pulses per revolution: 10; Resolution in pulses/mm: 0.05; Measuring increment (resolution in mm/pulse): 20, ± 18° / pulses per revolution; Measuring step deviation: ± 18° / pulses per revolution; Error limits: ± 4 mm/m, subject to the measuring wheel (wheel + surface); Duty cycle: ≤ 0.5 ± 5 %; Initialization time: 1.4 million cycles 4); Mounting position relative to...
Product detailsAdd to RFQ
DBV50E-22GLB2000 - Sick
Performance: Pulses per revolution: 2,000; Resolution in pulses/mm: 10; Measuring increment (resolution in mm/pulse): 0.1, ± 18° / pulses per revolution; Measuring step deviation: ± 18° / pulses per revolution; Error limits: ± 4 mm/m, subject to the measuring wheel (wheel + surface); Duty cycle: ≤ 0.5 ± 5 %; Initialization time: 1.4 million cycles 4); Mounting position relative to...
Product detailsAdd to RFQ
DBV50E-22GKB2500 - Sick
Performance: Pulses per revolution: 2,500; Resolution in pulses/mm: 12.5; Measuring increment (resolution in mm/pulse): 0.08, ± 18° / pulses per revolution; Measuring step deviation: ± 18° / pulses per revolution; Error limits: ± 4 mm/m, subject to the measuring wheel (wheel + surface); Duty cycle: ≤ 0.5 ± 5 %; Initialization time: 1.4 million cycles 4); Mounting position relative to...
Product detailsAdd to RFQ
DBV50E-22GNA2500 - Sick
Performance: Pulses per revolution: 2,500; Resolution in pulses/mm: 12.5; Measuring increment (resolution in mm/pulse): 0.08, ± 18° / pulses per revolution; Measuring step deviation: ± 18° / pulses per revolution; Error limits: ± 4 mm/m, subject to the measuring wheel (wheel + surface); Duty cycle: ≤ 0.5 ± 5 %; Initialization time: 1.4 million cycles 4); Mounting position relative to...
Product detailsAdd to RFQ
DBV50E-22GPA1000 - Sick
Performance: Pulses per revolution: 1,000; Resolution in pulses/mm: 5; Measuring increment (resolution in mm/pulse): 0.2, ± 18° / pulses per revolution; Measuring step deviation: ± 18° / pulses per revolution; Error limits: ± 4 mm/m, subject to the measuring wheel (wheel + surface); Duty cycle: ≤ 0.5 ± 5 %; Initialization time: 1.4 million cycles 4); Mounting position relative to...
Product detailsAdd to RFQ
DBV50E-22GNA2000 - Sick
Performance: Pulses per revolution: 2,000; Resolution in pulses/mm: 10; Measuring increment (resolution in mm/pulse): 0.1, ± 18° / pulses per revolution; Measuring step deviation: ± 18° / pulses per revolution; Error limits: ± 4 mm/m, subject to the measuring wheel (wheel + surface); Duty cycle: ≤ 0.5 ± 5 %; Initialization time: 1.4 million cycles 4); Mounting position relative to...
Product detailsAdd to RFQ
DBV50E-22GNA0200 - Sick
Performance: Pulses per revolution: 200; Resolution in pulses/mm: 1; Measuring increment (resolution in mm/pulse): 1, ± 18° / pulses per revolution; Measuring step deviation: ± 18° / pulses per revolution; Error limits: ± 4 mm/m, subject to the measuring wheel (wheel + surface); Duty cycle: ≤ 0.5 ± 5 %; Initialization time: 1.4 million cycles 4); Mounting position relative to...
Product detailsAdd to RFQ
DBV50E-22EPA2000 - Sick
Performance: Pulses per revolution: 2,000; Resolution in pulses/mm: 10; Measuring increment (resolution in mm/pulse): 0.1, ± 18° / pulses per revolution; Measuring step deviation: ± 18° / pulses per revolution; Error limits: ± 4 mm/m, subject to the measuring wheel (wheel + surface); Duty cycle: ≤ 0.5 ± 5 %; Initialization time: 1.4 million cycles 4); Mounting position relative to...
Product detailsAdd to RFQ
DBV50E-22EPA1000 - Sick
Performance: Pulses per revolution: 1,000; Resolution in pulses/mm: 5; Measuring increment (resolution in mm/pulse): 0.2, ± 18° / pulses per revolution; Measuring step deviation: ± 18° / pulses per revolution; Error limits: ± 4 mm/m, subject to the measuring wheel (wheel + surface); Duty cycle: ≤ 0.5 ± 5 %; Initialization time: 1.4 million cycles 4); Mounting position relative to...
Product detailsAdd to RFQ
DBV50E-22EPA0400 - Sick
Performance: Pulses per revolution: 400; Resolution in pulses/mm: 2; Measuring increment (resolution in mm/pulse): 0.5, ± 18° / pulses per revolution; Measuring step deviation: ± 18° / pulses per revolution; Error limits: ± 4 mm/m, subject to the measuring wheel (wheel + surface); Duty cycle: ≤ 0.5 ± 5 %; Initialization time: 1.4 million cycles 4); Mounting position relative to...
Product detailsAdd to RFQ
DBV50E-22GPA0500 - Sick
Performance: Pulses per revolution: 500; Resolution in pulses/mm: 2.5; Measuring increment (resolution in mm/pulse): 0.4, ± 18° / pulses per revolution; Measuring step deviation: ± 18° / pulses per revolution; Error limits: ± 4 mm/m, subject to the measuring wheel (wheel + surface); Duty cycle: ≤ 0.5 ± 5 %; Initialization time: 1.4 million cycles 4); Mounting position relative to...