DT60-N211B - Sick
Dx60, DT60. Measuring range: 200 mm ... 2,000 mm, 6 % remission, 200 mm ... 3,600 mm, 18 % remission, 200 mm ... 5,300 mm, 90 % remision. Response time: 50 ms, 30 ms. Repeatability: 10 mm. Light source: Laser, red. Laser protection class: 2 (EN 60825-1). Multifunctional input: 1x Laser off. Switching output (max. output current): 1 x NPN...
Product detailsAdd to RFQ
DT60-N111B - Sick
Dx60, DT60. Measuring range: 200 mm ... 2,800 mm, 6 % remission, 200 mm ... 5,000 mm, 18 % remission, 200 mm ... 5,300 mm, 18 % remission. Response time: 20 ms ... 150 ms. Repeatability: 8 mm. Light source: Laser, red. Laser protection class: 2 (EN 60825-1). Multifunctional input: 1x Laser off. Switching output (max. output current): 1 x...
Product detailsAdd to RFQ
DT60-P111B0228 - Sick
Dx60, DT60. Measuring range: 200 mm ... 2,800 mm, 18 % remission, 200 mm ... 2,800 mm, 6 % remission, 200 mm ... 5,000 mm, 18 % remission. Response time: 20 ms ... 150 ms. Repeatability: 8 mm. Light source: Laser, red. Laser protection class: 2 (EN 60825-1). Multifunctional input: 1x Laser off. Switching output (max. output current): 1 x...
Product detailsAdd to RFQ
DT60-P111B0230 - Sick
Dx60, DT60. Measuring range: 200 mm ... 2,800 mm, 6 % remission, 200 mm ... 3,000 mm, 18 % remission, 200 mm ... 5,000 mm, 18 % remission. Response time: 20 ms ... 150 ms. Repeatability: 8 mm. Light source: Laser, red. Laser protection class: 2 (EN 60825-1). Multifunctional input: 1x Laser off. Switching output (max. output current): 1 x...
Product detailsAdd to RFQ
DT60-N111B0253 - Sick
Dx60, DT60. Measuring range: 200 mm ... 2,800 mm, 6 % remission, 200 mm ... 5,000 mm, 18 % remission, 200 mm ... 5,300 mm, 18 % remission. Response time: 20 ms ... 150 ms. Repeatability: 8 mm. Light source: Laser, red. Laser protection class: 2 (EN 60825-1). Multifunctional input: 1x Laser off. Switching output (max. output current): 1 x...
Product detailsAdd to RFQ
DT60-P111B0220 - Sick
Dx60, DT60. Measuring range: 200 mm ... 2,800 mm, 6 % remission, 200 mm ... 5,000 mm, 18 % remission, 200 mm ... 5,300 mm, 18 % remission. Response time: 20 ms ... 150 ms. Repeatability: 8 mm. Light source: Laser, red. Laser protection class: 2 (EN 60825-1). Multifunctional input: 1x Laser off. Switching output (max. output current): 1 x...
Product detailsAdd to RFQ
DT60-P111B0240 - Sick
Dx60, DT60. Measuring range: 200 mm ... 2,800 mm, 6 % remission, 200 mm ... 4,000 mm, 18 % remission, 200 mm ... 5,000 mm, 18 % remission. Response time: 20 ms ... 150 ms. Repeatability: 8 mm. Light source: Laser, red. Laser protection class: 2 (EN 60825-1). Multifunctional input: 1x Laser off. Switching output (max. output current): 1 x...
Product detailsAdd to RFQ
DT50-P1123 - Sick
Dx50, DT50. Measuring range: 200 mm ... 10,000 mm, 90 % remision, 200 mm ... 2,500 mm, 6 % remission, 200 mm ... 5,000 mm, 18 % remission. Response time: 20 ms / 30 ms. Repeatability: 5 mm / 2.5 mm. Light source: Laser, red. Laser protection class: 1 (EN 60825-1). Multifunctional input: 1 x PNP.
Product detailsAdd to RFQ
DT50-P1124 - Sick
Dx50, DT50. Measuring range: 200 mm ... 10,000 mm, 90 % remision, 200 mm ... 2,500 mm, 6 % remission, 200 mm ... 5,000 mm, 18 % remission. Response time: 20 ms / 30 ms. Repeatability: 5 mm / 2.5 mm. Light source: Laser, red. Laser protection class: 1 (EN 60825-1). Multifunctional input: 1 x PNP.
Product detailsAdd to RFQ
DT50-P1114 - Sick
Dx50, DT50. Measuring range: 200 mm ... 10,000 mm, 90 % remision, 200 mm ... 4,000 mm, 6 % remission, 200 mm ... 6,500 mm, 18 % remission. Response time: 20 ms / 30 ms. Repeatability: 5 mm / 2.5 mm. Light source: Laser, red. Laser protection class: 2 (EN 60825-1). Multifunctional input: 1 x PNP.
Product detailsAdd to RFQ
DT60-P111B - Sick
Dx60, DT60. Measuring range: 200 mm ... 2,800 mm, 6 % remission, 200 mm ... 5,000 mm, 18 % remission, 200 mm ... 5,300 mm, 18 % remission. Response time: 20 ms ... 150 ms. Repeatability: 8 mm. Light source: Laser, red. Laser protection class: 2 (EN 60825-1). Multifunctional input: 1x Laser off. Switching output (max. output current): 1 x...
Product detailsAdd to RFQ
DT50-P2113 - Sick
Dx50, DT50 Hi. Measuring range: 200 mm ... 20,000 mm, 90 % remision, 200 mm ... 5,000 mm, 6 % remission, 200 mm ... 8,500 mm, 18 % remission. Response time: 15 ms / 30 ms / 80 ms. Repeatability: 3 mm / 2 mm / 1 mm. Light source: Laser, red. Laser protection class: 2 (EN 60825-1). Multifunctional input:...