[siemens_summary]
[catalog_children]
[catalog_search_products]
Mid range distance sensors

Mid range distance sensors

Items 61 - 72 of 102 from SICK ⍾ Last modified Sep 3, 2025

Mid range distance sensors ⍾ Page 6

Product detailsAdd to RFQ
DS60-N21211 - Sick
Dx60, DS60. Measuring range: 80 mm ... 2,400 mm, 6 % remission, 80 mm ... 4,600 mm, 18 % remission, 80 mm ... 6,000 mm, 90 % remision. Response time: 10 ms. Light source: Laser, red. Laser protection class: 2 (EN 60825-1). Switching output (max. output current): 2x NPN (100 mA).
Product detailsAdd to RFQ
DS60-N21111 - Sick
Dx60, DS60. Measuring range: 80 mm ... 2,400 mm, 6 % remission, 80 mm ... 4,600 mm, 18 % remission, 80 mm ... 6,000 mm, 90 % remision. Response time: 10 ms. Light source: Laser, infrared. Laser protection class: 1 (EN 60825-1). Switching output (max. output current): 2x NPN (100 mA).
Product detailsAdd to RFQ
DS50-P1112 - Sick
Dx50, DS50. Measuring range: 200 mm ... 10,000 mm, 90 % remision, 200 mm ... 4,000 mm, 6 % remission, 200 mm ... 6,000 mm, 18 % remission. Response time: 10 ms / 50 ms. Repeatability: 5 mm / 2.5 mm. Light source: Laser, red. Laser protection class: 2 (EN 60825-1). Multifunctional input: 1 x PNP.
Product detailsAdd to RFQ
DS50-P1122 - Sick
Dx50, DS50. Measuring range: 200 mm ... 10,000 mm, 90 % remision, 200 mm ... 4,000 mm, 6 % remission, 200 mm ... 6,000 mm, 18 % remission. Response time: 20 ms / 100 ms. Repeatability: 5 mm / 2.5 mm. Light source: Laser, red. Laser protection class: 1 (EN 60825-1). Multifunctional input: 1 x PNP.
Product detailsAdd to RFQ
DS60-N11121 - Sick
Dx60, DS60. Measuring range: 200 mm ... 20,000 mm, on Diamond Grade. Response time: 10 ms. Light source: Laser, infrared. Laser protection class: 1 (EN 60825-1). Multifunctional input: 1x Alignment laser. Switching output (max. output current): 2x NPN (100 mA).
Product detailsAdd to RFQ
DS60-N21311 - Sick
Dx60, DS60. Measuring range: 80 mm ... 2,400 mm, 6 % remission, 80 mm ... 4,600 mm, 18 % remission, 80 mm ... 6,000 mm, 90 % remision. Response time: 10 ms. Light source: Laser, infrared. Laser protection class: 1 (EN 60825-1). Switching output (max. output current): 2x NPN (100 mA).
Product detailsAdd to RFQ
DS50-N1112 - Sick
Dx50, DS50. Measuring range: 200 mm ... 10,000 mm, 90 % remision, 200 mm ... 4,000 mm, 6 % remission, 200 mm ... 6,000 mm, 18 % remission. Response time: 10 ms / 50 ms. Repeatability: 5 mm / 2.5 mm. Light source: Laser, red. Laser protection class: 2 (EN 60825-1). Multifunctional input: 1 x NPN.
Product detailsAdd to RFQ
DS40-P41211P01 - Sick
DS40. Measuring range: 80 mm ... 2,000 mm, 6 % remission, 80 mm ... 4,000 mm, 18 % remission, 80 mm ... 5,000 mm, 90 % remision. Response time: 10 ms. Light source: Laser, red. Laser protection class: 2 (EN 60825-1).
Product detailsAdd to RFQ
DS40-P41211 - Sick
DS40. Measuring range: 80 mm ... 2,000 mm, 6 % remission, 80 mm ... 4,000 mm, 18 % remission, 80 mm ... 5,000 mm, 90 % remision. Response time: 10 ms. Light source: Laser, red. Laser protection class: 2 (EN 60825-1).
Product detailsAdd to RFQ
DS30-P1255 - Sick
Dx30, DS30. Measuring range: 200 mm ... 2,000 mm, 18 % remission, 200 mm ... 2,000 mm, 6 % remission, 200 mm ... 2,000 mm, 90 % remision. Response time: 33 ms. Light source: Laser, infrared. Laser protection class: 1 (EN 60825-1).
Product detailsAdd to RFQ
DS40-P21211 - Sick
DS40. Measuring range: 80 mm ... 2,000 mm, 6 % remission, 80 mm ... 4,000 mm, 18 % remission, 80 mm ... 5,000 mm, 90 % remision. Response time: 10 ms. Light source: Laser, red. Laser protection class: 2 (EN 60825-1).
Product detailsAdd to RFQ
DS30-P2111S04 - Sick
Dx30, DS30. Measuring range: 200 mm ... 2,000 mm, 6 % remission, 200 mm ... 3,000 mm, 18 % remission, 200 mm ... 3,000 mm, 90 % remision. Response time: 10 ms. Light source: Laser, infrared. Laser protection class: 1 (EN 60825-1).