[siemens_summary]
[catalog_children]
[catalog_search_products]
Multiple light beam safety devices

Multiple light beam safety devices

Items 385 - 396 of 407 from SICK ⍾ Last modified Sep 4, 2025

Multiple light beam safety devices ⍾ Page 33

Product detailsAdd to RFQ
M20E-03240A221 - Sick
Safety-related parameters: Type: Type 2 (IEC 61496-1); Safety integrity level: SIL1 (IEC 61508)SILCL1 (EN 62061); Category: Category 2 (EN ISO 13849); Test rate (internal test): 13 /s (EN ISO 13849) 1); Maximum demand rate: ≤ 8 min⁻¹ (EN ISO 13849) 2); Performance level: PL c (EN ISO 13849); PFHD (mean probability of a dangerous failure per hour): 6.6 x 10-9...
Product detailsAdd to RFQ
M20E-03140A222 , M20S-03140A222 - Sick
Designation: M2000 Cascadable. Number of beams: 3. Muting with: Flexi Classic, Flexi Soft. Configuration method: hard wired.
Product detailsAdd to RFQ
M20E-02250A222 , M20S-02250A122 - Sick
Designation: M2000 RES/EDM. Number of beams: 2. Muting with: Flexi Classic, Flexi Soft. Configuration method: hard wired.
Product detailsAdd to RFQ
M20E-03140A221 - Sick
Safety-related parameters: Type: Type 2 (IEC 61496-1); Safety integrity level: SIL1 (IEC 61508)SILCL1 (EN 62061); Category: Category 2 (EN ISO 13849); Test rate (internal test): 13 /s (EN ISO 13849) 1); Maximum demand rate: ≤ 8 min⁻¹ (EN ISO 13849) 2); Performance level: PL c (EN ISO 13849); PFHD (mean probability of a dangerous failure per hour): 6.6 x 10-9...
Product detailsAdd to RFQ
M20E-03140A122 , M20S-03140A122 - Sick
Designation: M2000 Standard. Number of beams: 3. Muting with: Flexi Classic, Flexi Soft. Configuration method: hard wired.
Product detailsAdd to RFQ
M20E-03140A120 , M20S-03140A120 - Sick
Designation: M2000 Standard. Number of beams: 3. Muting with: Flexi Classic, Flexi Soft. Configuration method: hard wired.
Product detailsAdd to RFQ
M20E-02250A221 , M20S-02250A120 - Sick
Designation: M2000 RES/EDM. Number of beams: 2. Muting with: Flexi Classic, Flexi Soft. Configuration method: hard wired.
Product detailsAdd to RFQ
M20E-03140A221 , M20S-03140A120 - Sick
Designation: M2000 RES/EDM. Number of beams: 3. Muting with: Flexi Classic, Flexi Soft. Configuration method: hard wired.
Product detailsAdd to RFQ
M20E-02250A221 - Sick
Safety-related parameters: Type: Type 2 (IEC 61496-1); Safety integrity level: SIL1 (IEC 61508)SILCL1 (EN 62061); Category: Category 2 (EN ISO 13849); Test rate (internal test): 13 /s (EN ISO 13849) 1); Maximum demand rate: ≤ 8 min⁻¹ (EN ISO 13849) 2); Performance level: PL c (EN ISO 13849); PFHD (mean probability of a dangerous failure per hour): 6.6 x 10-9...
Product detailsAdd to RFQ
M20E-02250A120 , M20S-02250A120 - Sick
Designation: M2000 Standard. Number of beams: 2. Muting with: Flexi Classic, Flexi Soft. Configuration method: hard wired.
Product detailsAdd to RFQ
M20E-02150A222 , M20S-02150A222 - Sick
Designation: M2000 Cascadable. Number of beams: 2. Muting with: Flexi Classic, Flexi Soft. Configuration method: hard wired.
Product detailsAdd to RFQ
M20E-02150A222 - Sick
Safety-related parameters: Type: Type 2 (IEC 61496-1); Safety integrity level: SIL1 (IEC 61508)SILCL1 (EN 62061); Category: Category 2 (EN ISO 13849); Test rate (internal test): 13 /s (EN ISO 13849) 1); Maximum demand rate: ≤ 8 min⁻¹ (EN ISO 13849) 2); Performance level: PL c (EN ISO 13849); PFHD (mean probability of a dangerous failure per hour): 6.6 x 10-9...