[siemens_summary]
[catalog_children]
[catalog_search_products]

Opto-Electronic Protective Devices ⍾ Page 148

Product detailsAdd to RFQ
C4P-EA09010A00 - Sick
Features: Application: Normal industrial environment; System part: Receiver; Resolution: 14 mm; Scanning range: 20 m; Protective field height: 900 mm; Response time: 14 ms (Uncoded)28 ms (code 1 or code 2); No blind zones: Yes; Synchronization: Optical synchronisation; Items supplied: ReceiverTest rod with diameter corresponding to the resolution of the safety light curtainSafety instructionMounting instructionsOperating instructions for download; Safety-related parameters:...
Product detailsAdd to RFQ
C4P-EA07530A001000 - Sick
Features: Application: Normal industrial environment; System part: Receiver; Resolution: 30 mm; Scanning range: 30 m; Protective field height: 750 mm; Response time: 11 ms (Uncoded)16 ms (code 1 or code 2); No blind zones: Yes; Synchronization: Optical synchronisation; Items supplied: ReceiverSystem plug 1000Test rod with diameter corresponding to the resolution of the safety light curtainSafety instructionMounting instructionsOperating instructions for download;...
Product detailsAdd to RFQ
C4P-EA07531C00 - Sick
Features: Application: Normal industrial environment; System part: Receiver; Resolution: 30 mm; Scanning range: 30 m; Protective field height: 750 mm; Response time: 11 ms (Uncoded)16 ms (code 1 or code 2); No blind zones: Yes; Synchronization: Optical synchronisation; Items supplied: ReceiverTest rod with diameter corresponding to the resolution of the safety light curtainSafety instructionMounting instructionsOperating instructions for download; Safety-related parameters:...
Product detailsAdd to RFQ
C4P-EA07531D00 - Sick
Features: Application: Normal industrial environment; System part: Receiver; Resolution: 30 mm; Scanning range: 30 m; Protective field height: 750 mm; Response time: 11 ms (Uncoded)16 ms (code 1 or code 2); Synchronization: Optical synchronisation; End cap with integrated LED: ✔; Items supplied: ReceiverTest rod with diameter corresponding to the resolution of the safety light curtainSafety instructionMounting instructionsOperating instructions for download;...
Product detailsAdd to RFQ
C4P-EA07530A00 - Sick
Features: Application: Normal industrial environment; System part: Receiver; Resolution: 30 mm; Scanning range: 30 m; Protective field height: 750 mm; Response time: 11 ms (Uncoded)16 ms (code 1 or code 2); No blind zones: Yes; Synchronization: Optical synchronisation; Items supplied: ReceiverTest rod with diameter corresponding to the resolution of the safety light curtainSafety instructionMounting instructionsOperating instructions for download; Safety-related parameters:...
Product detailsAdd to RFQ
C4P-EA07511C00 - Sick
Features: Application: Normal industrial environment; System part: Receiver; Resolution: 14 mm; Scanning range: 20 m; Protective field height: 750 mm; Response time: 13 ms (Uncoded)25 ms (code 1 or code 2); No blind zones: Yes; Synchronization: Optical synchronisation; Items supplied: ReceiverTest rod with diameter corresponding to the resolution of the safety light curtainSafety instructionMounting instructionsOperating instructions for download; Safety-related parameters:...
Product detailsAdd to RFQ
C4P-EA07510A001300 - Sick
Features: Application: Normal industrial environment; System part: Receiver; Resolution: 14 mm; Scanning range: 20 m; Protective field height: 750 mm; Response time: 13 ms (Uncoded)25 ms (code 1 or code 2); No blind zones: Yes; Synchronization: Optical synchronisation; Items supplied: ReceiverSystem plug 1300Test rod with diameter corresponding to the resolution of the safety light curtainSafety instructionMounting instructionsOperating instructions for download;...
Product detailsAdd to RFQ
C4P-EA07511D00 - Sick
Features: Application: Normal industrial environment; System part: Receiver; Resolution: 14 mm; Scanning range: 20 m; Protective field height: 750 mm; Response time: 13 ms (Uncoded)25 ms (code 1 or code 2); Synchronization: Optical synchronisation; End cap with integrated LED: ✔; Items supplied: ReceiverTest rod with diameter corresponding to the resolution of the safety light curtainSafety instructionMounting instructionsOperating instructions for download;...
Product detailsAdd to RFQ
C4P-EA06030A001100 - Sick
Features: Application: Normal industrial environment; System part: Receiver; Resolution: 30 mm; Scanning range: 30 m; Protective field height: 600 mm; Response time: 10 ms (Uncoded)15 ms (code 1 or code 2); No blind zones: Yes; Synchronization: Optical synchronisation; Items supplied: ReceiverSystem plug 1100Test rod with diameter corresponding to the resolution of the safety light curtainSafety instructionMounting instructionsOperating instructions for download;...
Product detailsAdd to RFQ
C4P-EA06011D00 - Sick
Features: Application: Normal industrial environment; System part: Receiver; Resolution: 14 mm; Scanning range: 20 m; Protective field height: 600 mm; Response time: 13 ms (Uncoded)22 ms (code 1 or code 2); Synchronization: Optical synchronisation; End cap with integrated LED: ✔; Items supplied: ReceiverTest rod with diameter corresponding to the resolution of the safety light curtainSafety instructionMounting instructionsOperating instructions for download;...
Product detailsAdd to RFQ
C4P-EA06030A001000 - Sick
Features: Application: Normal industrial environment; System part: Receiver; Resolution: 30 mm; Scanning range: 30 m; Protective field height: 600 mm; Response time: 10 ms (Uncoded)15 ms (code 1 or code 2); No blind zones: Yes; Synchronization: Optical synchronisation; Items supplied: ReceiverSystem plug 1000Test rod with diameter corresponding to the resolution of the safety light curtainSafety instructionMounting instructionsOperating instructions for download;...
Product detailsAdd to RFQ
C4P-EA07510A00 - Sick
Features: Application: Normal industrial environment; System part: Receiver; Resolution: 14 mm; Scanning range: 20 m; Protective field height: 750 mm; Response time: 13 ms (Uncoded)25 ms (code 1 or code 2); No blind zones: Yes; Synchronization: Optical synchronisation; Items supplied: ReceiverTest rod with diameter corresponding to the resolution of the safety light curtainSafety instructionMounting instructionsOperating instructions for download; Safety-related parameters:...