C4C-SX12030A10000 - Sick
Features: Application: Explosive areas; Ex-approvals: ATEX for gas: II 3G Ex ec op is IIC T4 GcATEX for dust: II 3D Ex tc IIIC T135°C Dc; System part: Sender; Compatible receiver: 1220358; Resolution: 30 mm; Scanning range: 15 m; Protective field height: 1,200 mm; No blind zones: Yes; Synchronization: Optical synchronisation; Items supplied: Sender; Safety-related parameters: Type: Type 4 (IEC...
Product detailsAdd to RFQ
C4C-SX13530A10000 - Sick
Features: Application: Explosive areas; Ex-approvals: ATEX for gas: II 3G Ex ec op is IIC T4 GcATEX for dust: II 3D Ex tc IIIC T135°C Dc; System part: Sender; Compatible receiver: 1220359; Resolution: 30 mm; Scanning range: 15 m; Protective field height: 1,350 mm; No blind zones: Yes; Synchronization: Optical synchronisation; Items supplied: Sender; Safety-related parameters: Type: Type 4 (IEC...
Product detailsAdd to RFQ
C4C-SX13510A10000 - Sick
Features: Application: Explosive areas; Ex-approvals: ATEX for gas: II 3G Ex ec op is IIC T4 GcATEX for dust: II 3D Ex tc IIIC T135°C Dc; System part: Sender; Compatible receiver: 1220333; Resolution: 14 mm; Scanning range: 10 m; Protective field height: 1,350 mm; No blind zones: Yes; Synchronization: Optical synchronisation; Items supplied: Sender; Safety-related parameters: Type: Type 4 (IEC...
Product detailsAdd to RFQ
C4C-SX09010A10000 - Sick
Features: Application: Explosive areas; Ex-approvals: ATEX for gas: II 3G Ex ec op is IIC T4 GcATEX for dust: II 3D Ex tc IIIC T135°C Dc; System part: Sender; Compatible receiver: 1220330; Resolution: 14 mm; Scanning range: 10 m; Protective field height: 900 mm; No blind zones: Yes; Synchronization: Optical synchronisation; Items supplied: Sender; Safety-related parameters: Type: Type 4 (IEC...
Product detailsAdd to RFQ
C4C-SX06030A10000 - Sick
Features: Application: Explosive areas; Ex-approvals: ATEX for gas: II 3G Ex ec op is IIC T4 GcATEX for dust: II 3D Ex tc IIIC T135°C Dc; System part: Sender; Compatible receiver: 1220354; Resolution: 30 mm; Scanning range: 15 m; Protective field height: 600 mm; No blind zones: Yes; Synchronization: Optical synchronisation; Items supplied: Sender; Safety-related parameters: Type: Type 4 (IEC...
Product detailsAdd to RFQ
C4C-SX09030A10000 - Sick
Features: Application: Explosive areas; Ex-approvals: ATEX for gas: II 3G Ex ec op is IIC T4 GcATEX for dust: II 3D Ex tc IIIC T135°C Dc; System part: Sender; Compatible receiver: 1220356; Resolution: 30 mm; Scanning range: 15 m; Protective field height: 900 mm; No blind zones: Yes; Synchronization: Optical synchronisation; Items supplied: Sender; Safety-related parameters: Type: Type 4 (IEC...
Product detailsAdd to RFQ
C4C-SX07510A10000 - Sick
Features: Application: Explosive areas; Ex-approvals: ATEX for gas: II 3G Ex ec op is IIC T4 GcATEX for dust: II 3D Ex tc IIIC T135°C Dc; System part: Sender; Compatible receiver: 1220329; Resolution: 14 mm; Scanning range: 10 m; Protective field height: 750 mm; No blind zones: Yes; Synchronization: Optical synchronisation; Items supplied: Sender; Safety-related parameters: Type: Type 4 (IEC...
Product detailsAdd to RFQ
C4C-SX04530A10000 - Sick
Features: Application: Explosive areas; Ex-approvals: ATEX for gas: II 3G Ex ec op is IIC T4 GcATEX for dust: II 3D Ex tc IIIC T135°C Dc; System part: Sender; Compatible receiver: 1220353; Resolution: 30 mm; Scanning range: 15 m; Protective field height: 450 mm; No blind zones: Yes; Synchronization: Optical synchronisation; Items supplied: Sender; Safety-related parameters: Type: Type 4 (IEC...
Product detailsAdd to RFQ
C4C-SX03010A10000 - Sick
Features: Application: Explosive areas; Ex-approvals: ATEX for gas: II 3G Ex ec op is IIC T4 GcATEX for dust: II 3D Ex tc IIIC T135°C Dc; System part: Sender; Compatible receiver: 1220326; Resolution: 14 mm; Scanning range: 10 m; Protective field height: 300 mm; No blind zones: Yes; Synchronization: Optical synchronisation; Items supplied: Sender; Safety-related parameters: Type: Type 4 (IEC...
Product detailsAdd to RFQ
C4C-SX03030A10000 - Sick
Features: Application: Explosive areas; Ex-approvals: ATEX for gas: II 3G Ex ec op is IIC T4 GcATEX for dust: II 3D Ex tc IIIC T135°C Dc; System part: Sender; Compatible receiver: 1220352; Resolution: 30 mm; Scanning range: 15 m; Protective field height: 300 mm; No blind zones: Yes; Synchronization: Optical synchronisation; Items supplied: Sender; Safety-related parameters: Type: Type 4 (IEC...
Product detailsAdd to RFQ
C4C-SX06010A10000 - Sick
Features: Application: Explosive areas; Ex-approvals: ATEX for gas: II 3G Ex ec op is IIC T4 GcATEX for dust: II 3D Ex tc IIIC T135°C Dc; System part: Sender; Compatible receiver: 1220328; Resolution: 14 mm; Scanning range: 10 m; Protective field height: 600 mm; No blind zones: Yes; Synchronization: Optical synchronisation; Items supplied: Sender; Safety-related parameters: Type: Type 4 (IEC...
Product detailsAdd to RFQ
C4C-SV06030C10000 - Sick
Features: Application: Machines with strong shock or vibration loads; System part: Sender; Resolution: 30 mm; Scanning range: 6 m; Protective field height: 600 mm; No blind zones: Yes; Synchronization: Optical synchronisation; Items supplied: Sender; Safety-related parameters: Type: Type 4 (IEC 61496-1); Safety integrity level: SIL3 (IEC 61508)SILCL3 (IEC 62061); Category: Category 4 (ISO 13849-1); Performance level: PL e (ISO 13849-1);...