Product detailsAdd to RFQ
C4C-EX19530A10000 - Sick
Features: Application: Explosive areas; Ex-approvals: ATEX for gas: II 3G Ex ec op is IIC T4 GcATEX for dust: II 3D Ex tc IIIC T135°C Dc; System part: Receiver; Compatible sender: 1220350; Resolution: 30 mm; Scanning range: 15 m; Protective field height: 1,950 mm; Response time: 14 ms; No blind zones: Yes; Synchronization: Optical synchronisation; Items supplied: ReceiverTest rod with...
Product detailsAdd to RFQ
C4C-EX16510A10000 - Sick
Features: Application: Explosive areas; Ex-approvals: ATEX for gas: II 3G Ex ec op is IIC T4 GcATEX for dust: II 3D Ex tc IIIC T135°C Dc; System part: Receiver; Compatible sender: 1220322; Resolution: 14 mm; Scanning range: 10 m; Protective field height: 1,650 mm; Response time: 19 ms; No blind zones: Yes; Synchronization: Optical synchronisation; Items supplied: ReceiverTest rod with...
Product detailsAdd to RFQ
C4C-EX15010A10000 - Sick
Features: Application: Explosive areas; Ex-approvals: ATEX for gas: II 3G Ex ec op is IIC T4 GcATEX for dust: II 3D Ex tc IIIC T135°C Dc; System part: Receiver; Compatible sender: 1220321; Resolution: 14 mm; Scanning range: 10 m; Protective field height: 1,500 mm; Response time: 18 ms; No blind zones: Yes; Synchronization: Optical synchronisation; Items supplied: ReceiverTest rod with...
Product detailsAdd to RFQ
C4C-EX18030A10000 - Sick
Features: Application: Explosive areas; Ex-approvals: ATEX for gas: II 3G Ex ec op is IIC T4 GcATEX for dust: II 3D Ex tc IIIC T135°C Dc; System part: Receiver; Compatible sender: 1220349; Resolution: 30 mm; Scanning range: 15 m; Protective field height: 1,800 mm; Response time: 13 ms; No blind zones: Yes; Synchronization: Optical synchronisation; Items supplied: ReceiverTest rod with...
Product detailsAdd to RFQ
C4C-EX21010A10000 - Sick
Features: Application: Explosive areas; Ex-approvals: ATEX for gas: II 3G Ex ec op is IIC T4 GcATEX for dust: II 3D Ex tc IIIC T135°C Dc; System part: Receiver; Compatible sender: 1220325; Resolution: 14 mm; Scanning range: 10 m; Protective field height: 2,100 mm; Response time: 22 ms; No blind zones: Yes; Synchronization: Optical synchronisation; Items supplied: ReceiverTest rod with...
Product detailsAdd to RFQ
C4C-EX18010A10000 - Sick
Features: Application: Explosive areas; Ex-approvals: ATEX for gas: II 3G Ex ec op is IIC T4 GcATEX for dust: II 3D Ex tc IIIC T135°C Dc; System part: Receiver; Compatible sender: 1220323; Resolution: 14 mm; Scanning range: 10 m; Protective field height: 1,800 mm; Response time: 20 ms; No blind zones: Yes; Synchronization: Optical synchronisation; Items supplied: ReceiverTest rod with...
Product detailsAdd to RFQ
C4C-EX15030A10000 - Sick
Features: Application: Explosive areas; Ex-approvals: ATEX for gas: II 3G Ex ec op is IIC T4 GcATEX for dust: II 3D Ex tc IIIC T135°C Dc; System part: Receiver; Compatible sender: 1220347; Resolution: 30 mm; Scanning range: 15 m; Protective field height: 1,500 mm; Response time: 13 ms; No blind zones: Yes; Synchronization: Optical synchronisation; Items supplied: ReceiverTest rod with...
Product detailsAdd to RFQ
C4C-EX10510A10000 - Sick
Features: Application: Explosive areas; Ex-approvals: ATEX for gas: II 3G Ex ec op is IIC T4 GcATEX for dust: II 3D Ex tc IIIC T135°C Dc; System part: Receiver; Compatible sender: 1220318; Resolution: 14 mm; Scanning range: 10 m; Protective field height: 1,050 mm; Response time: 15 ms; No blind zones: Yes; Synchronization: Optical synchronisation; Items supplied: ReceiverTest rod with...
Product detailsAdd to RFQ
C4C-EX09030A10000 - Sick
Features: Application: Explosive areas; Ex-approvals: ATEX for gas: II 3G Ex ec op is IIC T4 GcATEX for dust: II 3D Ex tc IIIC T135°C Dc; System part: Receiver; Compatible sender: 1220343; Resolution: 30 mm; Scanning range: 15 m; Protective field height: 900 mm; Response time: 11 ms; No blind zones: Yes; Synchronization: Optical synchronisation; Items supplied: ReceiverTest rod with...
Product detailsAdd to RFQ
C4C-EX09010A10000 - Sick
Features: Application: Explosive areas; Ex-approvals: ATEX for gas: II 3G Ex ec op is IIC T4 GcATEX for dust: II 3D Ex tc IIIC T135°C Dc; System part: Receiver; Compatible sender: 1220317; Resolution: 14 mm; Scanning range: 10 m; Protective field height: 900 mm; Response time: 14 ms; No blind zones: Yes; Synchronization: Optical synchronisation; Items supplied: ReceiverTest rod with...
Product detailsAdd to RFQ
C4C-EX19510A10000 - Sick
Features: Application: Explosive areas; Ex-approvals: ATEX for gas: II 3G Ex ec op is IIC T4 GcATEX for dust: II 3D Ex tc IIIC T135°C Dc; System part: Receiver; Compatible sender: 1220324; Resolution: 14 mm; Scanning range: 10 m; Protective field height: 1,950 mm; Response time: 21 ms; No blind zones: Yes; Synchronization: Optical synchronisation; Items supplied: ReceiverTest rod with...
Product detailsAdd to RFQ
C4C-EX07530A10000 - Sick
Features: Application: Explosive areas; Ex-approvals: ATEX for gas: II 3G Ex ec op is IIC T4 GcATEX for dust: II 3D Ex tc IIIC T135°C Dc; System part: Receiver; Compatible sender: 1220342; Resolution: 30 mm; Scanning range: 15 m; Protective field height: 750 mm; Response time: 11 ms; No blind zones: Yes; Synchronization: Optical synchronisation; Items supplied: ReceiverTest rod with...