Skip to content
About Us
Select Brand
ABB
Schneider
Phoneix Contact
Siemens
Innomotics
Weidmuller
Gewiss
Fluke
SICK
Baumer
Dungs
Krom schroder
Festo
Norgren
Foxboro
Telemecanique
IFM
Pilz
Contact Us
English
English
Español
Deutsch
Polski
About Us
Select Brand
ABB
Schneider
Phoneix Contact
Siemens
Innomotics
Weidmuller
Gewiss
Fluke
SICK
Baumer
Dungs
Krom schroder
Festo
Norgren
Foxboro
Telemecanique
IFM
Pilz
Contact Us
English
English
Español
Deutsch
Polski
RFQ
Catalog
>
SICK
>
Opto-Electronic Protective Devices
[siemens_summary]
[catalog_children]
[catalog_search_products]
Opto-Electronic Protective Devices
Items 3229 - 3240 of 3443
from
SICK
⍾ Last modified Sep 3, 2025
▲
Accessories
Multiple light beam safety devices
Safety camera systems
Safety laser scanners
Safety light curtains
Single-beam photoelectric safety switch
Search
Opto-Electronic Protective Devices ⍾ Page 270
«
1
…
268
269
270
271
272
…
287
»
Product details
Add to RFQ
C2C-EA15010A10000 - Sick
Features: Application: Normal industrial environment; System part: Receiver; Compatible sender: 1216121; Resolution: 14 mm; Scanning range: 10 m; Protective field height: 1,500 mm; Response time: 18 ms; No blind zones: Yes; Synchronization: Optical synchronisation; Items supplied: ReceiverTest rod with diameter corresponding to the resolution of the safety light curtainSafety instructionMounting instructionsOperating instructions for download; Safety-related parameters: Type: Type 2 (IEC...
Product details
Add to RFQ
C2C-EA21010A10000 - Sick
Features: Application: Normal industrial environment; System part: Receiver; Compatible sender: 1216129; Resolution: 14 mm; Scanning range: 10 m; Protective field height: 2,100 mm; Response time: 22 ms; No blind zones: Yes; Synchronization: Optical synchronisation; Items supplied: ReceiverTest rod with diameter corresponding to the resolution of the safety light curtainSafety instructionMounting instructionsOperating instructions for download; Safety-related parameters: Type: Type 2 (IEC...
Product details
Add to RFQ
C2C-EA19530A10000 - Sick
Features: Application: Normal industrial environment; System part: Receiver; Compatible sender: 1213222; Resolution: 30 mm; Scanning range: 15 m; Protective field height: 1,950 mm; Response time: 14 ms; No blind zones: Yes; Synchronization: Optical synchronisation; Items supplied: ReceiverTest rod with diameter corresponding to the resolution of the safety light curtainSafety instructionMounting instructionsOperating instructions for download; Safety-related parameters: Type: Type 2 (IEC...
Product details
Add to RFQ
C2C-EA19510A10000 - Sick
Features: Application: Normal industrial environment; System part: Receiver; Compatible sender: 1216127; Resolution: 14 mm; Scanning range: 10 m; Protective field height: 1,950 mm; Response time: 21 ms; No blind zones: Yes; Synchronization: Optical synchronisation; Items supplied: ReceiverTest rod with diameter corresponding to the resolution of the safety light curtainSafety instructionMounting instructionsOperating instructions for download; Safety-related parameters: Type: Type 2 (IEC...
Product details
Add to RFQ
C2C-EA18030A10000 - Sick
Features: Application: Normal industrial environment; System part: Receiver; Compatible sender: 1213220; Resolution: 30 mm; Scanning range: 15 m; Protective field height: 1,800 mm; Response time: 13 ms; No blind zones: Yes; Synchronization: Optical synchronisation; Items supplied: ReceiverTest rod with diameter corresponding to the resolution of the safety light curtainSafety instructionMounting instructionsOperating instructions for download; Safety-related parameters: Type: Type 2 (IEC...
Product details
Add to RFQ
C2C-EA12010A10000 - Sick
Features: Application: Normal industrial environment; System part: Receiver; Compatible sender: 1213183; Resolution: 14 mm; Scanning range: 10 m; Protective field height: 1,200 mm; Response time: 16 ms; No blind zones: Yes; Synchronization: Optical synchronisation; Items supplied: ReceiverTest rod with diameter corresponding to the resolution of the safety light curtainSafety instructionMounting instructionsOperating instructions for download; Safety-related parameters: Type: Type 2 (IEC...
Product details
Add to RFQ
C2C-EA10530A10000 - Sick
Features: Application: Normal industrial environment; System part: Receiver; Compatible sender: 1213210; Resolution: 30 mm; Scanning range: 15 m; Protective field height: 1,050 mm; Response time: 11 ms; No blind zones: Yes; Synchronization: Optical synchronisation; Items supplied: ReceiverTest rod with diameter corresponding to the resolution of the safety light curtainSafety instructionMounting instructionsOperating instructions for download; Safety-related parameters: Type: Type 2 (IEC...
Product details
Add to RFQ
C2C-EA18010A10000 - Sick
Features: Application: Normal industrial environment; System part: Receiver; Compatible sender: 1216125; Resolution: 14 mm; Scanning range: 10 m; Protective field height: 1,800 mm; Response time: 20 ms; No blind zones: Yes; Synchronization: Optical synchronisation; Items supplied: ReceiverTest rod with diameter corresponding to the resolution of the safety light curtainSafety instructionMounting instructionsOperating instructions for download; Safety-related parameters: Type: Type 2 (IEC...
Product details
Add to RFQ
C25E-120303C11 , C25S-120103C11 - Sick
Designation: C2000 Standard IP69K Housing, including 15 m IP69K-rated cable. Resolution: 30 mm. Protective field height: 1,200 mm. Configuration method: hard wired.
Product details
Add to RFQ
C2C-EA03030A10000 - Sick
Features: Application: Normal industrial environment; System part: Receiver; Compatible sender: 1213200; Resolution: 30 mm; Scanning range: 15 m; Protective field height: 300 mm; Response time: 10 ms; No blind zones: Yes; Synchronization: Optical synchronisation; Items supplied: ReceiverTest rod with diameter corresponding to the resolution of the safety light curtainSafety instructionMounting instructionsOperating instructions for download; Safety-related parameters: Type: Type 2 (IEC...
Product details
Add to RFQ
C25E-120303C11 , C25S-120203C11 - Sick
Designation: C2000 Standard IP69K Housing, including 15 m IP69K-rated cable. Resolution: 30 mm. Protective field height: 1,200 mm. Configuration method: hard wired.
Product details
Add to RFQ
C2C-EA04510A10000 - Sick
Features: Application: Normal industrial environment; System part: Receiver; Compatible sender: 1213189; Resolution: 14 mm; Scanning range: 10 m; Protective field height: 450 mm; Response time: 12 ms; No blind zones: Yes; Synchronization: Optical synchronisation; Items supplied: ReceiverTest rod with diameter corresponding to the resolution of the safety light curtainSafety instructionMounting instructionsOperating instructions for download; Safety-related parameters: Type: Type 2 (IEC...
« Prev page
Next page »