[siemens_summary]
[catalog_children]
[catalog_search_products]

Opto-Electronic Protective Devices ⍾ Page 79

Product detailsAdd to RFQ
MICS3-ABAZ40IZ1 - Sick
Features: Protective field range: 4 m; Warning field range: 40 m; Number of simultaneously monitored fields: ≤ 4 1); Number of fields: 8; Number of monitoring cases: 8; Scanning angle: 275°; Resolution (can be configured): 30 mm40 mm50 mm70 mm150 mm200 mm; Angular resolution: 0.39°; Response time: ≥ 95 ms; Protective field supplement: 65 mm; Safety-related parameters: Type: Type 3...
Product detailsAdd to RFQ
MICS3-ABAZ40IZ1P01 - Sick
Features: Protective field range: 4 m; Warning field range: 40 m; Number of simultaneously monitored fields: ≤ 4 1); Number of fields: 8; Number of monitoring cases: 8; Scanning angle: 275°; Resolution (can be configured): 30 mm40 mm50 mm70 mm150 mm200 mm; Angular resolution: 0.39°; Response time: ≥ 95 ms; Protective field supplement: 65 mm; Safety-related parameters: Type: Type 3...
Product detailsAdd to RFQ
MICS3-ABAZ40ZA1 - Sick
Features: Protective field range: 4 m; Warning field range: 40 m; Number of simultaneously monitored fields: ≤ 4 1); Number of fields: 8; Number of monitoring cases: 8; Scanning angle: 275°; Resolution (can be configured): 30 mm40 mm50 mm70 mm150 mm200 mm; Angular resolution: 0.39°; Response time: ≥ 95 ms; Protective field supplement: 65 mm; Safety-related parameters: Type: Type 3...
Product detailsAdd to RFQ
MICS3-AAAZ90BZ1P01 - Sick
Features: Protective field range: 9 m; Number of simultaneously monitored fields: ≤ 4 1) 2); Number of fields: 4 3); Number of monitoring cases: 1; Scanning angle: 275°; Resolution (can be configured): 30 mm40 mm50 mm60 mm70 mm150 mm200 mm; Angular resolution: 0.1°; Response time: ≥ 90 ms; Protective field supplement: 100 mm; Safety-related parameters: Type: Type 3 (IEC 61496);...
Product detailsAdd to RFQ
MICS3-AAAZ55AZ1P01 - Sick
Features: Protective field range: 5.5 m; Warning field range: 40 m; Number of simultaneously monitored fields: ≤ 4 1) 2); Number of fields: 8 3); Number of monitoring cases: 2; Scanning angle: 275°; Resolution (can be configured): 30 mm40 mm50 mm70 mm150 mm200 mm; Angular resolution: 0.39°; Response time: ≥ 70 ms; Protective field supplement: 65 mm; Safety-related parameters: Type:...
Product detailsAdd to RFQ
MICS3-AAAZ90BZ1 - Sick
Features: Protective field range: 9 m; Number of simultaneously monitored fields: ≤ 4 1); Number of fields: 4; Number of monitoring cases: 1; Scanning angle: 275°; Resolution (can be configured): 30 mm40 mm50 mm60 mm70 mm150 mm200 mm; Angular resolution: 0.1°; Response time: ≥ 90 ms; Protective field supplement: 100 mm; Safety-related parameters: Type: Type 3 (IEC 61496); Safety integrity...
Product detailsAdd to RFQ
MICS3-AAAZ40BZ1P01 - Sick
Features: Protective field range: 4 m; Number of simultaneously monitored fields: ≤ 4 1) 2); Number of fields: 4 3); Number of monitoring cases: 1; Scanning angle: 275°; Resolution (can be configured): 30 mm40 mm50 mm70 mm150 mm200 mm; Angular resolution: 0.39°; Response time: ≥ 70 ms; Protective field supplement: 65 mm; Safety-related parameters: Type: Type 3 (IEC 61496); Safety...
Product detailsAdd to RFQ
MICS3-AAAZ55BZ1P01 - Sick
Features: Protective field range: 5.5 m; Number of simultaneously monitored fields: ≤ 4 1) 2); Number of fields: 4 3); Number of monitoring cases: 1; Scanning angle: 275°; Resolution (can be configured): 30 mm40 mm50 mm70 mm150 mm200 mm; Angular resolution: 0.39°; Response time: ≥ 70 ms; Protective field supplement: 65 mm; Safety-related parameters: Type: Type 3 (IEC 61496); Safety...
Product detailsAdd to RFQ
MICS3-AAAZ55AZ1 - Sick
Features: Protective field range: 5.5 m; Warning field range: 40 m; Number of simultaneously monitored fields: ≤ 4 1); Number of fields: 8; Number of monitoring cases: 2; Scanning angle: 275°; Resolution (can be configured): 30 mm40 mm50 mm70 mm150 mm200 mm; Angular resolution: 0.39°; Response time: ≥ 70 ms; Protective field supplement: 65 mm; Safety-related parameters: Type: Type 3...
Product detailsAdd to RFQ
MICS3-AAAZ90AZ1P01 - Sick
Features: Protective field range: 9 m; Warning field range: 64 m; Number of simultaneously monitored fields: ≤ 4 1) 2); Number of fields: 8 3); Number of monitoring cases: 2; Scanning angle: 275°; Resolution (can be configured): 30 mm40 mm50 mm60 mm70 mm150 mm200 mm; Angular resolution: 0.1°; Response time: ≥ 90 ms; Protective field supplement: 100 mm; Safety-related parameters:...
Product detailsAdd to RFQ
MICS3-AAAZ55BZ1 - Sick
Features: Protective field range: 5.5 m; Number of simultaneously monitored fields: ≤ 4 1); Number of fields: 4; Number of monitoring cases: 1; Scanning angle: 275°; Resolution (can be configured): 30 mm40 mm50 mm70 mm150 mm200 mm; Angular resolution: 0.39°; Response time: ≥ 70 ms; Protective field supplement: 65 mm; Safety-related parameters: Type: Type 3 (IEC 61496); Safety integrity level:...
Product detailsAdd to RFQ
MICS3-AAAZ90AZ1 - Sick
Features: Protective field range: 9 m; Warning field range: 64 m; Number of simultaneously monitored fields: ≤ 4 1); Number of fields: 8; Number of monitoring cases: 2; Scanning angle: 275°; Resolution (can be configured): 30 mm40 mm50 mm60 mm70 mm150 mm200 mm; Angular resolution: 0.1°; Response time: ≥ 90 ms; Protective field supplement: 100 mm; Safety-related parameters: Type: Type...