Product detailsAdd to RFQ
MACX MCR-SL-IDSI-I - Phoenix Contact
Output signal conditioner - MACX MCR-SL-IDSI-I - 2865971; Output signal conditioner, HART. Isolates and transfers 0/4-20 mA signals to a load (I/P converters, control valves, displays). Electrical 3-way isolation, wire break recognition, SIL 2 in accordance with IEC 61508, screw connection.
Product detailsAdd to RFQ
PI-EX-SD-21-40 - Phoenix Contact
Solenoid driver - PI-EX-SD-21-40 - 2865913; Ex i solenoid driver, pluggable. To control intrinsically safe solenoid valves, alarm modules as well as simple electric equipment installed in Ex areas. For Group IIC gases, loop-powered. Electrical isolation.
Product detailsAdd to RFQ
MACX MCR-EX-SL-RPSSI-I-UP - Phoenix Contact
Power/input isolating amplifier - MACX MCR-EX-SL-RPSSI-I-UP - 2865793; Ex i repeater power supply and input isolating amplifier, HART Sends fed or active 0/4-20 mA signals from the Ex area to a load (active or passive) to the safe area. Electrical 3-way isolation; SIL 2, wide range power supply.
Product detailsAdd to RFQ
MACX MCR-EX-SL-SD-21-40-LP - Phoenix Contact
Solenoid driver - MACX MCR-EX-SL-SD-21-40-LP - 2865764; Ex i solenoid driver. For the intrinsically safe control of Ex i solenoid valves, alarm modules or LEDs installed in the Ex area. Current limitation at 40 mA. For gases up to Group IIC, loop-powered, electrical isolation, SIL 3. Screw connection.
Product detailsAdd to RFQ
MACX MCR-EX-T-UIREL-UP - Phoenix Contact
Temperature measuring transducer - MACX MCR-EX-T-UIREL-UP - 2865751; Programmable temperature transducer with analog output and 3 limit value relays, intrinsically safe signal input, resistance thermometer in 2-, 3-, or 4-wire technology, thermocouples, electrical isolation, wide-range power supply, screw connection, SIL, PL.
Product detailsAdd to RFQ
PI-EX-AIS - Phoenix Contact
Input isolating amplifier - PI-EX-AIS - 2865696; Ex i analog input: Input isolating amplifier, HART. Sends 4-20 mA signals from externally supplied measuring transducers installed in Ex areas to a load in safe areas. Galvanic 3-way isolation (input / output / supply).
Product detailsAdd to RFQ
MACX MCR-PTB - Phoenix Contact
Power and error message module - MACX MCR-PTB - 2865625; Power and fault signaling module with screw connection, including corresponding ME 17,5 TBUS 1,5/ 5-ST-3,81 GY DIN rail connector
Product detailsAdd to RFQ
MACX MCR-EX-SL-RTD-I-NC - Phoenix Contact
Temperature measuring transducer - MACX MCR-EX-SL-RTD-I-NC - 2865573; Ex i temperature measuring transducer: Converts signals from resistance thermometers installed in Ex areas and transmits a 0/4-20 mA signal to a load in the safe area. Freely programmable, 3-way isolation.
Product detailsAdd to RFQ
MACX MCR-EX-T-UI-UP - Phoenix Contact
Temperature measuring transducer - MACX MCR-EX-T-UI-UP - 2865654; Freely programmable Ex-i temperature transducer with analog output and 1 limit value relay, standard configuration, resistance thermometer in 2-, 3-, or 4-wire technology, thermocouples, electrical isolation, wide-range power supply, screw connection, SIL, PL.
Product detailsAdd to RFQ
MACX MCR-EX-SL-SD-21-60-LP - Phoenix Contact
Solenoid driver - MACX MCR-EX-SL-SD-21-60-LP - 2865515; Ex i solenoid driver. For the intrinsically safe control of Ex i solenoid valves, alarm modules or LEDs installed in the Ex area. Current limitation at 58 mA. For gases up to Group IIB, loop-powered, electrical isolation, SIL 3. Screw connection.
Product detailsAdd to RFQ
MACX MCR-EX-SL-SD-24-48-LP - Phoenix Contact
Solenoid driver - MACX MCR-EX-SL-SD-24-48-LP - 2865609; Ex i solenoid driver. For the intrinsically safe control of Ex i solenoid valves, alarm modules or LEDs installed in the Ex area. Current limitation at 48 mA. For gases up to Group IIC, loop-powered, electrical isolation, SIL 3. Screw connection.
Product detailsAdd to RFQ
MACX MCR-EX-SL-TC-I-NC - Phoenix Contact
Temperature measuring transducer - MACX MCR-EX-SL-TC-I-NC - 2865586; Ex i temperature measuring transducer: Converts signals from thermocouples installed in Ex areas and mV sources and transmits a 0/4-20 mA signal to a load in a safe area. Freely programmable, 3-way isolation