[siemens_summary]
[catalog_children]
[catalog_search_products]

Phoenix Contact ⍾ Page 954

Product detailsAdd to RFQ
MACX MCR-SL-2NAM-R-UP-SP - Phoenix Contact
Isolation amplifier - MACX MCR-SL-2NAM-R-UP-SP - 2924304; 2-channel NAMUR signal conditioner with wide range power supply for proximity sensors and switches. In terms of signal output, for each channel there is a relay with a changeover contact available. Line fault detection (LFD), 3-way isolation, Push-in connection, SIL 2.
Product detailsAdd to RFQ
MACX MCR-SL-RPSSI-I-SP - Phoenix Contact
Power/input isolating amplifier - MACX MCR-SL-RPSSI-I-SP - 2924207; Repeater power supply and input isolating amplifier, HART. Transfers supplied or active 0/4 - 20 mA signals to a load (active or passive). 3-way electrical isolation, SIL 2 according to IEC 61508.
Product detailsAdd to RFQ
MACX MCR-PTB-SP - Phoenix Contact
Power and error message module - MACX MCR-PTB-SP - 2924184; Power and fault signaling module with Push-in connection, including corresponding ME 17,5 TBUS 1,5/ 5-ST-3,81 GY DIN rail connector
Product detailsAdd to RFQ
MACX MCR-EX-SL-RPSS-2I-2I-SP - Phoenix Contact
Signal isolator - MACX MCR-EX-SL-RPSS-2I-2I-SP - 2924676; Ex i measuring transducer repeater power supply, 2-channel, HART-transparent. Supplies Ex i 2-conductor measuring transducers and transmits the 4…20 mA signal from the Ex area to the safe area. 5-way electrical isolation, Push-in connection, up to SIL 3, PL.
Product detailsAdd to RFQ
MACX MCR-EX-T-UI-UP-SP - Phoenix Contact
Temperature measuring transducer - MACX MCR-EX-T-UI-UP-SP - 2924689; Programmable Ex-i temperature transducer with analog output and 1 limit value relay, standard configuration, resistance thermometer in 2-, 3-, or 4-wire technology, thermocouples, electrical isolation, wide-range power supply, Push-in connection, SIL, PL.
Product detailsAdd to RFQ
MACX MCR-EX-SL-RPSSI-2I-SP - Phoenix Contact
Repeater power supply - MACX MCR-EX-SL-RPSSI-2I-SP - 2924236; Ex i measuring transducer power supply and input signal conditioner, HART-transparent. Transfers supplied or active 0/4…20 mA electrical isolation signals from the Ex area to two loads in the safe area. 4-way electrical isolation, Push-in connection, SIL, PL.
Product detailsAdd to RFQ
MACX MCR-SL-RPSSI-I-UP-SP - Phoenix Contact
Repeater power supply - MACX MCR-SL-RPSSI-I-UP-SP - 2924210; Repeater power supply for supplying 2 and 3-conductor transmitters with HART transmission and wide range power supply, SIL, Push-in connection
Product detailsAdd to RFQ
MACX MCR-SL-IDSI-I-SP - Phoenix Contact
Output signal conditioner - MACX MCR-SL-IDSI-I-SP - 2924223; Output signal conditioner, HART. Isolates and transmits 0/4-20 mA signals to a load (I/P converters, control valves, displays). Electrical 3-way isolation, wire break recognition, SIL 2 in accordance with IEC 61508, Push-in connection.
Product detailsAdd to RFQ
MACX MCR-EX-SL-SD-24-48-LP-SP - Phoenix Contact
Solenoid driver - MACX MCR-EX-SL-SD-24-48-LP-SP - 2924126; Ex i solenoid driver. For the intrinsically safe control of Ex i solenoid valves, alarm modules or LEDs installed in the Ex area. Current limitation at 48 mA. For gases up to Group IIC, loop-powered, electrical isolation, SIL 3. Push-in connection.
Product detailsAdd to RFQ
MACX MCR-EX-SL-SD-21-60-LP-SP - Phoenix Contact
Solenoid driver - MACX MCR-EX-SL-SD-21-60-LP-SP - 2924100; Ex i solenoid driver. For the intrinsically safe control of Ex i solenoid valves, alarm modules or LEDs installed in the Ex area. Current limitation at 58 mA. For gases up to Group IIB, loop-powered, electrical isolation, SIL 3. Push-in connection.
Product detailsAdd to RFQ
MACX MCR-EX-SL-2NAM-R-UP-SP - Phoenix Contact
Isolation amplifier - MACX MCR-EX-SL-2NAM-R-UP-SP - 2924249; 2-channel Ex-i NAMUR isolation amplifier with wide-range power supply for proximity sensors and switches. Every channel has a relay with PDT contact as a signal output. Line fault detection (LFD), 3-way isolation, SIL 2.
Product detailsAdd to RFQ
MACX MCR-EX-SL-SD-21-40-LP-SP - Phoenix Contact
Solenoid driver - MACX MCR-EX-SL-SD-21-40-LP-SP - 2924139; Ex i solenoid driver. For the intrinsically safe control of Ex i solenoid valves, alarm modules or LEDs installed in the Ex area. Current limitation at 40 mA. For gases up to Group IIC, loop-powered, electrical isolation, SIL 3. Push-in connection.