[siemens_summary]
[catalog_children]
[catalog_search_products]

Position sensors ⍾ Page 73

Product detailsAdd to RFQ
NN506A - Ifm
Inductive sensor; Connection to switching amplifiers : yes; Switching amplifiers : connection to certified intrinsically safe circuits with the max. values: U = 15 V / I = 50 mA / P = 120 mW; Operating voltage [V] : 8.2 DC; (1kΩ); Supply voltage DC [V] : 7.5...15; (when used outside the hazardous area); Protection class : III; Actuator wiring...
Product detailsAdd to RFQ
NN507A - Ifm
Inductive sensor; Connection to switching amplifiers : yes; Switching amplifiers : connection to certified intrinsically safe circuits with the max. values: U = 15 V / I = 50 mA / P = 120 mW; Operating voltage [V] : 8.2 DC; (1kΩ); Supply voltage DC [V] : 7.5...15; (when used outside the hazardous area); Protection class : III; Actuator wiring...
Product detailsAdd to RFQ
NT5005 - Ifm
Inductive NAMUR sensor; Connection to switching amplifiers : yes; Switching amplifiers : connection to certified intrinsically safe circuits with the max. values: U = 15 V / I = 50 mA / P = 120 mW; Nominal voltage DC [V] : 8.2; (1kΩ); Supply voltage DC [V] : 7.5...30; (when used outside the hazardous area); Protection class : III; Electrical...
Product detailsAdd to RFQ
NS501A - Ifm
Inductive NAMUR sensor; Connection to switching amplifiers : yes; Switching amplifiers : connection to certified intrinsically safe circuits with the max. values: U = 15 V / I = 50 mA / P = 120 mW; Nominal voltage DC [V] : 8.2; (1kΩ); Supply voltage DC [V] : 7.5...30; (when used outside the hazardous area); Protection class : III; Electrical...
Product detailsAdd to RFQ
NT5001 - Ifm
Inductive NAMUR sensor; Connection to switching amplifiers : yes; Switching amplifiers : connection to certified intrinsically safe circuits with the max. values: U = 15 V / I = 50 mA / P = 120 mW; Nominal voltage DC [V] : 8.2; (1kΩ); Supply voltage DC [V] : 7.5...30; (when used outside the hazardous area); Protection class : III; Electrical...
Product detailsAdd to RFQ
O1D103 - Ifm
Photoelectric distance sensor; Operating voltage [V] : 18...30 DC; Protection class : III; Reverse polarity protection : yes; Typ. lifetime [h] : 50000; Total number of outputs : 2; Electrical design : NPN; Number of digital outputs : 2; Output function : normally open / normally closed; (programmable); Max. current load per output [mA] : 200; Number of analogue outputs...
Product detailsAdd to RFQ
NS5002 - Ifm
Inductive NAMUR sensor; Connection to switching amplifiers : yes; Switching amplifiers : connection to certified intrinsically safe circuits with the max. values: U = 15 V / I = 50 mA / P = 120 mW; Nominal voltage DC [V] : 8.2; (1kΩ); Supply voltage DC [V] : 7.5...30; (when used outside the hazardous area); Electrical design : NAMUR; Output...
Product detailsAdd to RFQ
O1D100 - Ifm
Photoelectric distance sensor; Operating voltage [V] : 18...30 DC; (operating voltage "supply class 2" according to cULus); Protection class : III; Reverse polarity protection : yes; Typ. lifetime [h] : 50000; Total number of outputs : 2; Electrical design : PNP; Number of digital outputs : 2; Output function : normally open / normally closed; (parameterisable); Max. current load per...
Product detailsAdd to RFQ
NS5003 - Ifm
Inductive NAMUR sensor; Connection to switching amplifiers : yes; Switching amplifiers : connection to certified intrinsically safe circuits with the max. values: U = 15 V / I = 50 mA / P = 120 mW; Nominal voltage DC [V] : 8.2; (1kΩ); Supply voltage DC [V] : 7.5...30; (when used outside the hazardous area); Protection class : III; Electrical...
Product detailsAdd to RFQ
O1D102 - Ifm
Photoelectric distance sensor; Operating voltage [V] : 18...30 DC; Protection class : III; Reverse polarity protection : yes; Typ. lifetime [h] : 50000; Total number of outputs : 2; Electrical design : PNP; Number of digital outputs : 2; Output function : normally open / normally closed; (programmable); Max. current load per output [mA] : 200; Number of analogue outputs...
Product detailsAdd to RFQ
NI5004 - Ifm
Inductive NAMUR sensor; Connection to switching amplifiers : yes; Switching amplifiers : connection to certified intrinsically safe circuits with the max. values: U = 15 V / I = 50 mA / P = 120 mW; Nominal voltage DC [V] : 8.2; (1kΩ); Supply voltage DC [V] : 7.5...30; (when used outside the hazardous area); Protection class : III; Electrical...
Product detailsAdd to RFQ
NI5003 - Ifm
Inductive NAMUR sensor; Connection to switching amplifiers : yes; Switching amplifiers : connection to certified intrinsically safe circuits with the max. values: U = 15 V / I = 50 mA / P = 120 mW; Nominal voltage DC [V] : 8.2; (1kΩ); Supply voltage DC [V] : 7.5...30; (when used outside the hazardous area); Protection class : II; Electrical...