[siemens_summary]
[catalog_children]
[catalog_search_products]

Pressure measurement ⍾ Page 125

Product detailsAdd to RFQ
7MF4034-1FY10-1AC7-Z A01 - Siemens
SITRANS P DS III / P410, PROFIBUS PA, transmitter for pressure Measuring cell filling silicone oil, normal cleaning Nominal measuring range 160 bar g (2320 psi g), overload limit 250 bar Version for diaphragm pressure controller. Consider additional delivery time for Remote seal. Remote seals must be ordered with an additional article no. Process connection: female thread 1/2-14 npt Die-cast...
Product detailsAdd to RFQ
7MF4034-1FC10-1AC6-Z A02 - Siemens
SITRANS P DS III / P410, PROFIBUS PA, transmitter for pressure Measuring cell filling silicone oil, normal cleaning Nominal measuring range 160 bar g (2320 psi g), overload limit 250 bar Diaphragm hastelloy measuring cell hastelloy Process connection: female thread 1/2-14 npt Die-cast aluminium housing Standard design None explosion protection Electric connection and cable inlet: cable gland 1/2-14 npt Housing...
Product detailsAdd to RFQ
7MF4034-3DA00-1AF6-Z E10 - Siemens
SITRANS P DS III / P410, PROFIBUS PA, transmitter for pressure Measuring cell filling inert measuring cell cleaning grease-free Nominal measuring range 16 bar g (232 psi g), overload limit 32 bar Diaphragm stainless steel, measuring cell stainless steel Process connection: connection shank G1/2 B to EN 837-1 Die-cast aluminium housing Standard design None explosion protection Electric connection and cable...
Product detailsAdd to RFQ
7MF4034-1EA10-2BB6-Z C11 - Siemens
SITRANS P DS III / P410, PROFIBUS PA, transmitter for pressure Measuring cell filling silicone oil, normal cleaning Nominal measuring range 63 bar g (914 psi g), overload limit 100 bar Diaphragm stainless steel, measuring cell stainless steel Process connection: female thread 1/2-14 npt Die-cast aluminium housing International version english inscription and documentation on cd Explosion protection eex ia Electric...
Product detailsAdd to RFQ
7MF4034-1JA13-1NC6-Z A02 - Siemens
SITRANS P DS III / P410, PROFIBUS PA, transmitter for pressure Measuring cell filling silicone oil, normal cleaning Nominal measuring range 700 bar g (19153 psi g), overload limit 800 bar Diaphragm stainless steel, measuring cell stainless steel Process connection: female thread 1/2-14 npt Housing made of stainless steel precision casting Standard design Explosion protection fm + csa Electric connection...
Product detailsAdd to RFQ
7MF4034-1FC10-1AC6-Z A02 - Siemens
SITRANS P DS III / P410, PROFIBUS PA, transmitter for pressure Measuring cell filling silicone oil, normal cleaning Nominal measuring range 160 bar g (2320 psi g), overload limit 250 bar Diaphragm hastelloy measuring cell hastelloy Process connection: female thread 1/2-14 npt Die-cast aluminium housing Standard design None explosion protection Electric connection and cable inlet: cable gland 1/2-14 npt Housing...
Product detailsAdd to RFQ
7MF4034-1FC10-1FC6-Z A02 - Siemens
SITRANS P DS III / P410, PROFIBUS PA, transmitter for pressure Measuring cell filling silicone oil, normal cleaning Nominal measuring range 160 bar g (2320 psi g), overload limit 250 bar Diaphragm hastelloy measuring cell hastelloy Process connection: female thread 1/2-14 npt Die-cast aluminium housing Standard design FM + CSA intrinsic safe (is) Electric connection and cable inlet: cable gland...
Product detailsAdd to RFQ
7MF4034-1EA60-2AC6-Z A02 - Siemens
SITRANS P DS III / P410, PROFIBUS PA, transmitter for pressure Measuring cell filling silicone oil, normal cleaning Nominal measuring range 63 bar g (914 psi g), overload limit 100 bar Diaphragm stainless steel, measuring cell stainless steel Process connection: Male thread 1/2-14NPT Die-cast aluminium housing International version english inscription and documentation on cd None explosion protection Electric connection and...
Product detailsAdd to RFQ
7MF4034-1EA10-1NC6-Z A01 - Siemens
SITRANS P DS III / P410, PROFIBUS PA, transmitter for pressure Measuring cell filling silicone oil, normal cleaning Nominal measuring range 63 bar g (914 psi g), overload limit 100 bar Diaphragm stainless steel, measuring cell stainless steel Process connection: female thread 1/2-14 npt Die-cast aluminium housing Standard design Explosion protection fm + csa Electric connection and cable inlet: cable...
Product detailsAdd to RFQ
7MF4034-1EC10-1AC6-Z A02 - Siemens
SITRANS P DS III / P410, PROFIBUS PA, transmitter for pressure Measuring cell filling silicone oil, normal cleaning Nominal measuring range 63 bar g (914 psi g), overload limit 100 bar Diaphragm hastelloy measuring cell hastelloy Process connection: female thread 1/2-14 npt Die-cast aluminium housing Standard design None explosion protection Electric connection and cable inlet: cable gland 1/2-14 npt Housing...
Product detailsAdd to RFQ
7MF4034-1EA60-1EB6 - Siemens
SITRANS P DS III / P410, PROFIBUS PA, transmitter for pressure Measuring cell filling silicone oil, normal cleaning Nominal measuring range 63 bar g (914 psi g), overload limit 100 bar Diaphragm stainless steel, measuring cell stainless steel Process connection: Male thread 1/2-14NPT Die-cast aluminium housing Standard design Ex nA/ic - Use in Zone 2 Electric connection and cable inlet:...
Product detailsAdd to RFQ
7MF4034-1EA10-1AC6-Z A02 - Siemens
SITRANS P DS III / P410, PROFIBUS PA, transmitter for pressure Measuring cell filling silicone oil, normal cleaning Nominal measuring range 63 bar g (914 psi g), overload limit 100 bar Diaphragm stainless steel, measuring cell stainless steel Process connection: female thread 1/2-14 npt Die-cast aluminium housing Standard design None explosion protection Electric connection and cable inlet: cable gland 1/2-14...