LR2759 - Ifm
Continuous level sensor (guided wave radar); Operating voltage [V] : 18...30 DC; Protection class : III; Reverse polarity protection : yes; Power-on delay time [s] : 5; Measuring error [mm] : ± 7; Offset error [mm] : 5; Resolution [mm] : 1; Zero signal (current) [mA] : 4.0; Full signal (current) [mA] : 20; Temperature drift per 10 K :...
Product detailsAdd to RFQ
LR3000 - Ifm
Continuous level sensor (guided wave radar); Operating voltage [V] : 18...30 DC; Protection class : III; Reverse polarity protection : yes; Power-on delay time [s] : 5; Repeatability [mm] : ± 5; Measuring error [mm] : ± 7; Offset error [mm] : 5; Resolution [mm] : 1; Zero signal (voltage) [V] : 0; Zero signal (current) [mA] : 4.0; Full...
Product detailsAdd to RFQ
LMT392 - Ifm
Sensor for point level detection; Medium temperature [°C] : -25...100; (applications subject to the German Federal Water Act 0...100 °C); Medium temperature short time [°C] : -25...150; (1 h; applications subject to the German Federal Water Act : 0...100 °C); Medium temperature [°C] : -25...85; (applications subject to the German Federal Water Act : 0...85 °C); Operating voltage [V] :...
Product detailsAdd to RFQ
LMT102 - Ifm
Sensor for point level detection; Medium temperature [°C] : -20...100; Medium temperature short time [°C] : -20...150; (1 h); Operating voltage [V] : 18...30 DC; Protection class : III; Reverse polarity protection : yes; Measuring principle : capacitive; Total number of outputs : 2; Output signal : switching signal; IO-Link; Electrical design : PNP/NPN; Number of digital outputs : 2; Output...
Product detailsAdd to RFQ
LK1223 - Ifm
Continuous level sensor with overspill monitoring; Medium temperature [°C] : 0...35; (with climatic tube E43101: 35...60 °C; not for applications to WHG (German Federal Water Act)); Medium temperature [°C] : 0...70; Medium temperature short time [°C] : 0...90; (< 1 h); Maximum speed of the change of level [mm/s] : 200; Operating voltage [V] : 12...30 DC; Protection class :...
Product detailsAdd to RFQ
LMT03A - Ifm
Sensor for point level detection in hazardous areas; Operating voltage [V] : 18...30 DC; Protection class : III; Reverse polarity protection : yes; Measuring principle : capacitive; Total number of outputs : 2; Output signal : switching signal; IO-Link; Electrical design : PNP/NPN; Number of digital outputs : 2; Output function : normally open / normally closed; (parameterisable); Max. voltage drop...
Product detailsAdd to RFQ
LK3122 - Ifm
Electronic level sensor; Medium temperature [°C] : 0...35; (with climatic tube E43100: 35...65 °C); Medium temperature [°C] : 0...70; Medium temperature short time [°C] : 0...90; (< 1 h); Operating voltage [V] : 18...30 DC; Protection class : III; Reverse polarity protection : yes; Power-on delay time [s] : < 3; Measuring principle : capacitive; Total number of outputs : 2;...
Product detailsAdd to RFQ
LK1024 - Ifm
Electronic level sensor; Medium temperature [°C] : 0...35; (with climatic tube E43102: 35...55 °C); Medium temperature [°C] : 0...70; Medium temperature short time [°C] : 0...90; (< 1 h); Operating voltage [V] : 18...30 DC; Protection class : III; Reverse polarity protection : yes; Power-on delay time [s] : < 3; Measuring principle : capacitive; Total number of outputs : 2;...
Product detailsAdd to RFQ
LK1222 - Ifm
Continuous level sensor with overspill monitoring; Medium temperature [°C] : 0...35; (with climatic tube E43100: 35...65 °C; not for applications to WHG (German Federal Water Act)); Medium temperature [°C] : 0...70; Medium temperature short time [°C] : 0...90; (< 1 h); Operating voltage [V] : 12...30 DC; Protection class : III; Reverse polarity protection : yes; Power-on delay time [s]...
Product detailsAdd to RFQ
LMC100 - Ifm
Sensor for point level detection; Medium temperature [°C] : -25...100; Operating voltage [V] : 18...30 DC; Protection class : III; Reverse polarity protection : yes; Total number of outputs : 2; Output signal : switching signal; IO-Link; Electrical design : PNP/NPN; Number of digital outputs : 2; Output function : normally open / normally closed; (parameterisable); Max. voltage drop switching...
Product detailsAdd to RFQ
LMC110 - Ifm
Sensor for point level detection; Medium temperature [°C] : -25...100; Operating voltage [V] : 18...30 DC; Protection class : III; Reverse polarity protection : yes; Total number of outputs : 2; Output signal : switching signal; IO-Link; Electrical design : PNP/NPN; Number of digital outputs : 2; Output function : normally open / normally closed; (parameterisable); Max. voltage drop switching...
Product detailsAdd to RFQ
LK8124 - Ifm
Electronic level sensor; Medium temperature [°C] : 0...35; (with climatic tube E43102: 35...55 °C); Medium temperature [°C] : 0...70; Medium temperature short time [°C] : 0...90; (< 1 h); Medium temperature [°C] : 0...35; (with climatic tube E43102 ; 35...55 °C); Operating voltage [V] : 18...30 DC; Protection class : III; Reverse polarity protection : yes; Power-on delay time [s]...