[siemens_summary]
[catalog_children]
[catalog_search_products]
Safety light curtains

Safety light curtains

Items 1117 - 1128 of 2816 from SICK ⍾ Last modified Sep 3, 2025

Safety light curtains ⍾ Page 94

Product detailsAdd to RFQ
C4P-EA10510A001300 - Sick
Features: Application: Normal industrial environment; System part: Receiver; Resolution: 14 mm; Scanning range: 20 m; Protective field height: 1,050 mm; Response time: 15 ms (Uncoded)31 ms (code 1 or code 2); No blind zones: Yes; Synchronization: Optical synchronisation; Items supplied: ReceiverSystem plug 1300Test rod with diameter corresponding to the resolution of the safety light curtainSafety instructionMounting instructionsOperating instructions for download;...
Product detailsAdd to RFQ
C4P-EA10510A00 - Sick
Features: Application: Normal industrial environment; System part: Receiver; Resolution: 14 mm; Scanning range: 20 m; Protective field height: 1,050 mm; Response time: 15 ms (Uncoded)31 ms (code 1 or code 2); No blind zones: Yes; Synchronization: Optical synchronisation; Items supplied: ReceiverTest rod with diameter corresponding to the resolution of the safety light curtainSafety instructionMounting instructionsOperating instructions for download; Safety-related parameters:...
Product detailsAdd to RFQ
C4P-EA0903S001 - Sick
Features: Application: Normal industrial environment; System part: Receiver; Resolution: 30 mm; Scanning range: 30 m; Protective field height: 900 mm; Response time: 11 ms (Uncoded)17 ms (code 1 or code 2); No blind zones: Yes; Synchronization: Optical synchronisation; Items supplied: Receiver with preassembled system plug M12, 5-pinTest rod with diameter corresponding to the resolution of the safety light curtainSafety instructionMounting...
Product detailsAdd to RFQ
C4P-EA10511D00 - Sick
Features: Application: Normal industrial environment; System part: Receiver; Resolution: 14 mm; Scanning range: 20 m; Protective field height: 1,050 mm; Response time: 15 ms (Uncoded)31 ms (code 1 or code 2); Synchronization: Optical synchronisation; End cap with integrated LED: ✔; Items supplied: ReceiverTest rod with diameter corresponding to the resolution of the safety light curtainSafety instructionMounting instructionsOperating instructions for download;...
Product detailsAdd to RFQ
C4P-EA10510A001000 - Sick
Features: Application: Normal industrial environment; System part: Receiver; Resolution: 14 mm; Scanning range: 20 m; Protective field height: 1,050 mm; Response time: 15 ms (Uncoded)31 ms (code 1 or code 2); No blind zones: Yes; Synchronization: Optical synchronisation; Items supplied: ReceiverSystem plug 1000Test rod with diameter corresponding to the resolution of the safety light curtainSafety instructionMounting instructionsOperating instructions for download;...
Product detailsAdd to RFQ
C4P-EA10510A001100 - Sick
Features: Application: Normal industrial environment; System part: Receiver; Resolution: 14 mm; Scanning range: 20 m; Protective field height: 1,050 mm; Response time: 15 ms (Uncoded)31 ms (code 1 or code 2); No blind zones: Yes; Synchronization: Optical synchronisation; Items supplied: ReceiverSystem plug 1100Test rod with diameter corresponding to the resolution of the safety light curtainSafety instructionMounting instructionsOperating instructions for download;...
Product detailsAdd to RFQ
C4P-EA10511C00 - Sick
Features: Application: Normal industrial environment; System part: Receiver; Resolution: 14 mm; Scanning range: 20 m; Protective field height: 1,050 mm; Response time: 15 ms (Uncoded)31 ms (code 1 or code 2); No blind zones: Yes; Synchronization: Optical synchronisation; Items supplied: ReceiverTest rod with diameter corresponding to the resolution of the safety light curtainSafety instructionMounting instructionsOperating instructions for download; Safety-related parameters:...
Product detailsAdd to RFQ
C4P-EA09010A001100 - Sick
Features: Application: Normal industrial environment; System part: Receiver; Resolution: 14 mm; Scanning range: 20 m; Protective field height: 900 mm; Response time: 14 ms (Uncoded)28 ms (code 1 or code 2); No blind zones: Yes; Synchronization: Optical synchronisation; Items supplied: ReceiverSystem plug 1100Test rod with diameter corresponding to the resolution of the safety light curtainSafety instructionMounting instructionsOperating instructions for download;...
Product detailsAdd to RFQ
C4P-EA09010A001000 - Sick
Features: Application: Normal industrial environment; System part: Receiver; Resolution: 14 mm; Scanning range: 20 m; Protective field height: 900 mm; Response time: 14 ms (Uncoded)28 ms (code 1 or code 2); No blind zones: Yes; Synchronization: Optical synchronisation; Items supplied: ReceiverSystem plug 1000Test rod with diameter corresponding to the resolution of the safety light curtainSafety instructionMounting instructionsOperating instructions for download;...
Product detailsAdd to RFQ
C4P-EA09031C00 - Sick
Features: Application: Normal industrial environment; System part: Receiver; Resolution: 30 mm; Scanning range: 30 m; Protective field height: 900 mm; Response time: 11 ms (Uncoded)17 ms (code 1 or code 2); No blind zones: Yes; Synchronization: Optical synchronisation; Items supplied: ReceiverTest rod with diameter corresponding to the resolution of the safety light curtainSafety instructionMounting instructionsOperating instructions for download; Safety-related parameters:...
Product detailsAdd to RFQ
C4P-EA10510A001200 - Sick
Features: Application: Normal industrial environment; System part: Receiver; Resolution: 14 mm; Scanning range: 20 m; Protective field height: 1,050 mm; Response time: 15 ms (Uncoded)31 ms (code 1 or code 2); No blind zones: Yes; Synchronization: Optical synchronisation; Items supplied: ReceiverSystem plug 1200Test rod with diameter corresponding to the resolution of the safety light curtainSafety instructionMounting instructionsOperating instructions for download;...
Product detailsAdd to RFQ
C4P-EA09011D00 - Sick
Features: Application: Normal industrial environment; System part: Receiver; Resolution: 14 mm; Scanning range: 20 m; Protective field height: 900 mm; Response time: 14 ms (Uncoded)28 ms (code 1 or code 2); Synchronization: Optical synchronisation; End cap with integrated LED: ✔; Items supplied: ReceiverTest rod with diameter corresponding to the resolution of the safety light curtainSafety instructionMounting instructionsOperating instructions for download;...