[siemens_summary]
[catalog_children]
[catalog_search_products]

Safety Switches ⍾ Page 8

Product detailsAdd to RFQ
T4000-1RCA04 - Sick
T4000 Multi Evaluation unit. Product family: T4000 Multi. System part: Evaluation unit.
Product detailsAdd to RFQ
T4000-1RBA01 - Sick
T4000 Standard Evaluation unit. Product family: T4000 Standard. System part: Evaluation unit. Connection type: Plug-in terminals.
Product detailsAdd to RFQ
T4000-DNA10P - Sick
T4000 StandardT4000 Multi Sensor. Product family: T4000 Multi, T4000 Standard. System part: Sensor. Connection type: Cable. Cable length: 10 m.
Product detailsAdd to RFQ
STR1-SAXU10P5 - Sick
Features: System part: Sensor; Sensor principle: Transponder; Number of safe outputs: 2; Auxiliary contact (AUX): 1 (Switching behavior complementary to OSSDs); Safe switch on distance Sao: 14 mm (–10 ... +70 °C) 1)10 mm (–30 ... –10 °C) 1); Safe switch off distance Sar: 28 mm 1); Active sensor surfaces: 3; Actuation directions: 5; Coding: Uniquely coded; Safety-related parameters: Safety...
Product detailsAdd to RFQ
STR1-SAXU03P8 - Sick
Features: System part: Sensor; Sensor principle: Transponder; Number of safe outputs: 2; Auxiliary contact (AUX): 1 (Switching behavior complementary to OSSDs); Safe switch on distance Sao: 14 mm (–10 ... +70 °C) 1)10 mm (–30 ... –10 °C) 1); Safe switch off distance Sar: 28 mm 1); Active sensor surfaces: 3; Actuation directions: 5; Coding: Uniquely coded; Safety-related parameters: Safety...
Product detailsAdd to RFQ
STR1-SAXU0AC5 - Sick
Features: System part: Sensor; Sensor principle: Transponder; Number of safe outputs: 2; Auxiliary contact (AUX): 1 (Switching behavior complementary to OSSDs); Safe switch on distance Sao: 14 mm (–10 ... +70 °C) 1)10 mm (–30 ... –10 °C) 1); Safe switch off distance Sar: 28 mm 1); Active sensor surfaces: 3; Actuation directions: 5; Coding: Uniquely coded; Safety-related parameters: Safety...
Product detailsAdd to RFQ
STR1-SAXM10P5 - Sick
Features: System part: Sensor; Sensor principle: Transponder; Number of safe outputs: 2; Auxiliary contact (AUX): 1 (Switching behavior complementary to OSSDs); Safe switch on distance Sao: 14 mm (–10 ... +70 °C) 1)10 mm (–30 ... –10 °C) 1); Safe switch off distance Sar: 28 mm 1); Active sensor surfaces: 3; Actuation directions: 5; Coding: Universally coded; Safety-related parameters: Safety...
Product detailsAdd to RFQ
STR1-SAXM0AC8S02 - Sick
Features: System part: Sensor; Sensor principle: Transponder; Number of safe outputs: 2; Auxiliary contact (AUX): 1 (switching behavior equivalent to actuator in the protected switch-on state); Safe switch on distance Sao: 14 mm (–10 ... +70 °C) 1)10 mm (–30 ... –10 °C) 1); Safe switch off distance Sar: 28 mm 1); Active sensor surfaces: 3; Actuation directions: 5; Coding:...
Product detailsAdd to RFQ
STR1-SASU10P8 - Sick
Features: System part: Sensor and actuator; Sensor principle: Transponder; Number of safe outputs: 2; Auxiliary contact (AUX): 1 (Switching behavior complementary to OSSDs); Safe switch on distance Sao: 10 mm (–30 °C ... +70 °C) 1); Safe switch off distance Sar: 25 mm 1); Active sensor surfaces: 3; Actuation directions: 5; Coding: Uniquely coded; Safety-related parameters: Safety integrity level: SIL3...
Product detailsAdd to RFQ
STR1-SAXU03P5 - Sick
Features: System part: Sensor; Sensor principle: Transponder; Number of safe outputs: 2; Auxiliary contact (AUX): 1 (Switching behavior complementary to OSSDs); Safe switch on distance Sao: 14 mm (–10 ... +70 °C) 1)10 mm (–30 ... –10 °C) 1); Safe switch off distance Sar: 28 mm 1); Active sensor surfaces: 3; Actuation directions: 5; Coding: Uniquely coded; Safety-related parameters: Safety...
Product detailsAdd to RFQ
STR1-SAXU0AC8 - Sick
Features: System part: Sensor; Sensor principle: Transponder; Number of safe outputs: 2; Auxiliary contact (AUX): 1 (Switching behavior complementary to OSSDs); Safe switch on distance Sao: 14 mm (–10 ... +70 °C) 1)10 mm (–30 ... –10 °C) 1); Safe switch off distance Sar: 28 mm 1); Active sensor surfaces: 3; Actuation directions: 5; Coding: Uniquely coded; Safety-related parameters: Safety...
Product detailsAdd to RFQ
STR1-SAXM10P8 - Sick
Features: System part: Sensor; Sensor principle: Transponder; Number of safe outputs: 2; Auxiliary contact (AUX): 1 (Switching behavior complementary to OSSDs); Safe switch on distance Sao: 14 mm (–10 ... +70 °C) 1)10 mm (–30 ... –10 °C) 1); Safe switch off distance Sar: 28 mm 1); Active sensor surfaces: 3; Actuation directions: 5; Coding: Universally coded; Safety-related parameters: Safety...