Product detailsAdd to RFQ
OD2-P85W20U0 - Sick
OD Value, 0 V ... 10 V (≥ 10 kΩ). Data interface: 0 V ... 10 V (≥ 10 kΩ). Linearity: ± 40 µm. Typ. light spot size (distance): 0.8 mm x 1.3 mm (85 mm). Resolution: 10 µm. Measuring range: 65 mm ... 105 mm, 6 % ... 90 % remission. Connection type: Connector, M12, 8-pin. Housing material: PBT...
Product detailsAdd to RFQ
OD2-P85W20I2 - Sick
OD Value, 4 mA ... 20 mA (≤ 300 Ω). Data interface: 4 mA ... 20 mA (≤ 300 Ω). Linearity: ± 40 µm. Typ. light spot size (distance): 0.8 mm x 1.3 mm (85 mm). Resolution: 10 µm. Measuring range: 65 mm ... 105 mm, 6 % ... 90 % remission. Connection type: Cable, 2 m. Housing material: PBT...
Product detailsAdd to RFQ
OD50-10N850 - Sick
OD Hi. Data interface: 1 x 4 mA ... 20 mA (≤ 300 Ω). Linearity: ± 200 µm. Typ. light spot size (distance): 0.8 mm x 0.8 mm (50 mm). Resolution: 10 µm. Measuring range: 40 mm ... 60 mm, 6 % ... 90 % remission. Connection type: Connector M12, 8-pin. Housing material: Zinc housing with glass lens.
Product detailsAdd to RFQ
OD2-P85W20A0 - Sick
OD Value, RS-422. Data interface: RS-422. Linearity: ± 40 µm. Typ. light spot size (distance): 0.8 mm x 1.3 mm (85 mm). Resolution: 10 µm. Measuring range: 65 mm ... 105 mm, 6 % ... 90 % remission. Connection type: Connector, M12, 8-pin. Housing material: PBT housing with PMMA lens.
Product detailsAdd to RFQ
OD2-P85W20C0 - Sick
OD Value. Linearity: ± 40 µm. Typ. light spot size (distance): 0.8 mm x 1.3 mm (85 mm). Resolution: 10 µm. Measuring range: 65 mm ... 105 mm, 6 % ... 90 % remission. Connection type: Connector, M12, 8-pin. Housing material: PBT housing with PMMA lens.
Product detailsAdd to RFQ
OD2-P85W20I0 - Sick
OD Value, 4 mA ... 20 mA (≤ 300 Ω). Data interface: 4 mA ... 20 mA (≤ 300 Ω). Linearity: ± 40 µm. Typ. light spot size (distance): 0.8 mm x 1.3 mm (85 mm). Resolution: 10 µm. Measuring range: 65 mm ... 105 mm, 6 % ... 90 % remission. Connection type: Connector, M12, 8-pin. Housing material: PBT...
Product detailsAdd to RFQ
OD2-P50W10C2 - Sick
OD Value. Linearity: ± 20 µm. Typ. light spot size (distance): 0.5 mm x 1 mm (50 mm). Resolution: 5 µm. Measuring range: 40 mm ... 60 mm, 6 % ... 90 % remission. Connection type: Cable, 2 m. Housing material: PBT housing with PMMA lens.
Product detailsAdd to RFQ
OD2-P50W10U2 - Sick
OD Value, 0 V ... 10 V (≥ 10 kΩ). Data interface: 0 V ... 10 V (≥ 10 kΩ). Linearity: ± 20 µm. Typ. light spot size (distance): 0.5 mm x 1 mm (50 mm). Resolution: 5 µm. Measuring range: 40 mm ... 60 mm, 6 % ... 90 % remission. Connection type: Cable, 2 m. Housing material: PBT...
Product detailsAdd to RFQ
OD2-P50W10I2 - Sick
OD Value, 4 mA ... 20 mA (≤ 300 Ω). Data interface: 4 mA ... 20 mA (≤ 300 Ω). Linearity: ± 20 µm. Typ. light spot size (distance): 0.5 mm x 1 mm (50 mm). Resolution: 5 µm. Measuring range: 40 mm ... 60 mm, 6 % ... 90 % remission. Connection type: Cable, 2 m. Housing material: PBT...
Product detailsAdd to RFQ
OD2-P50W10U0 - Sick
OD Value, 0 V ... 10 V (≥ 10 kΩ). Data interface: 0 V ... 10 V (≥ 10 kΩ). Linearity: ± 20 µm. Typ. light spot size (distance): 0.5 mm x 1 mm (50 mm). Resolution: 5 µm. Measuring range: 40 mm ... 60 mm, 6 % ... 90 % remission. Connection type: Connector, M12, 8-pin. Housing material: PBT...
Product detailsAdd to RFQ
OD2-P85W20C2 - Sick
OD Value. Linearity: ± 40 µm. Typ. light spot size (distance): 0.8 mm x 1.3 mm (85 mm). Resolution: 10 µm. Measuring range: 65 mm ... 105 mm, 6 % ... 90 % remission. Connection type: Cable, 2 m. Housing material: PBT housing with PMMA lens.
Product detailsAdd to RFQ
OD2-P300W200I0 - Sick
OD Value, 4 mA ... 20 mA (≤ 300 Ω). Data interface: 4 mA ... 20 mA (≤ 300 Ω). Linearity: ± 1.2 mm. Typ. light spot size (distance): 1.9 mm x 3.9 m (300 mm). Resolution: 100 µm. Measuring range: 100 mm ... 500 mm, 6 % ... 90 % remission. Connection type: Connector, M12, 8-pin. Housing material: PBT...