MLG02A-0145I13250 - Sick
Features: Device version: Pro - Advanced functionality; Sensor principle: Sender/receiver; Minimum detectable object (MDO): 2.5 mm, 4.5 mm 1) 2) 3); Beam separation: 2.5 mm; Number of beams: 59; Detection height: 145 mm; Software features (default)Interface RS-485System status, flow counter, RLC1 ... RLC16Baud rate RS-485500 kbit/sQ1Number of broken beams/NBBQ2 / INTeach inputTeachBlanking, high speed mode: Software features (default); Operating modeStandard✔Transparent✔Dust-...
Product detailsAdd to RFQ
MLG02A-0145I13201 - Sick
Features: Device version: Pro - Advanced functionality; Sensor principle: Sender/receiver; Minimum detectable object (MDO): 2.5 mm, 4.5 mm 1) 2) 3); Beam separation: 2.5 mm; Number of beams: 59; Detection height: 145 mm; Software features (default)Interface RS-485System status, virtual outputs, number of broken beams, height control (last beam)/LBB, height control (first beam)/FBB, oudside dimension, inside dimensionBaud rate RS-4859.6 kbit/sQ1Presence detectionQ2...
Product detailsAdd to RFQ
MLG02A-0145R13201 - Sick
Features: Device version: Pro - Advanced functionality; Sensor principle: Sender/receiver; Minimum detectable object (MDO): 2.5 mm, 4.5 mm 1) 2) 3); Beam separation: 2.5 mm; Number of beams: 59; Detection height: 145 mm; Software features (default)Q1Presence detectionQ2 / INTeach inputQ3Presence detectionQ4 / IN2Presence detectionTeachStandard mode: Software features (default); Operating modeStandard✔Transparent✔Dust- and sunlight-resistant✔: Operating mode; FunctionCross beam✔Beam blanking✔High-speed scan✔High measurement accuracy✔:...
Product detailsAdd to RFQ
MLG02A-0145B13201 - Sick
Features: Device version: Pro - Advanced functionality; Sensor principle: Sender/receiver; Minimum detectable object (MDO): 2.5 mm, 4.5 mm 1) 2) 3); Beam separation: 2.5 mm; Number of beams: 59; Detection height: 145 mm; Software features (default)QA1Number of broken beams/NBBQA2Height measurement (last beam)/LBBQ1Presence detectionQ2 / INTeach inputTeachStandard mode: Software features (default); Operating modeStandard✔Transparent✔Dust- and sunlight-resistant✔: Operating mode; FunctionCross beam✔Beam blanking✔High-speed scan✔High...
Product detailsAdd to RFQ
MLG02A-0295I13250 - Sick
Features: Device version: Pro - Advanced functionality; Sensor principle: Sender/receiver; Minimum detectable object (MDO): 2.5 mm, 4.5 mm 1) 2) 3); Beam separation: 2.5 mm; Number of beams: 119; Detection height: 295 mm; Software features (default)Interface RS-485System status, flow counter, RLC1 ... RLC16Baud rate RS-485500 kbit/sQ1Number of broken beams/NBBQ2 / INTeach inputTeachBlanking, high speed mode: Software features (default); Operating modeStandard✔Transparent✔Dust-...
Product detailsAdd to RFQ
MICS3-CCAZ55PZ1P01 - Sick
Features: Protective field range: 5.5 m; Warning field range: 40 m; Number of simultaneously monitored fields: ≤ 8 1); Number of fields: 128; Number of monitoring cases: 128; Scanning angle: 275°; Resolution (can be configured): 30 mm40 mm50 mm70 mm150 mm200 mm; Angular resolution: 0.39°; Response time: ≥ 95 ms; Protective field supplement: 65 mm; Safety-related parameters: Type: Type 3...
Product detailsAdd to RFQ
MICS3-CCAZ90LZ1P01 - Sick
Features: Protective field range: 9 m; Warning field range: 64 m; Number of simultaneously monitored fields: ≤ 4 1); Number of fields: 128; Number of monitoring cases: 128; Scanning angle: 275°; Resolution (can be configured): 30 mm40 mm50 mm60 mm70 mm150 mm200 mm; Angular resolution: 0.1°; Response time: ≥ 115 ms; Protective field supplement: 100 mm; Safety-related parameters: Type: Type...
Product detailsAdd to RFQ
MICS3-CCAZ90LZ1 - Sick
Features: Protective field range: 9 m; Warning field range: 64 m; Number of simultaneously monitored fields: ≤ 4 1); Number of fields: 128; Number of monitoring cases: 128; Scanning angle: 275°; Resolution (can be configured): 30 mm40 mm50 mm60 mm70 mm150 mm200 mm; Angular resolution: 0.1°; Response time: ≥ 115 ms; Protective field supplement: 100 mm; Safety-related parameters: Type: Type...
Product detailsAdd to RFQ
MICSX-CLNNZZZZ1 - Sick
Technical specifications: Accessory group: Plug connectors and cables; Accessory family: Other connectors and cables; Connection type head A: System plug; Special feature: Integrated configuration memory; Description: System connection: voltage supply: 1 x M12 male connector, 5-pin, L-coded, EtherNet: 2 x SCRJ female connector for push-pull male connector (optical fibers); Classifications: ECl@ss 5.0: 27279290; ECl@ss 5.1.4: 27279290; ECl@ss 6.0: 27279221; ECl@ss...
Product detailsAdd to RFQ
MICS3-CCAZ90PZ1 - Sick
Features: Protective field range: 9 m; Warning field range: 64 m; Number of simultaneously monitored fields: ≤ 4 1); Number of fields: 128; Number of monitoring cases: 128; Scanning angle: 275°; Resolution (can be configured): 30 mm40 mm50 mm60 mm70 mm150 mm200 mm; Angular resolution: 0.1°; Response time: ≥ 115 ms; Protective field supplement: 100 mm; Safety-related parameters: Type: Type...
Product detailsAdd to RFQ
MICS3-CCAZ90PZ1P01 - Sick
Features: Protective field range: 9 m; Warning field range: 64 m; Number of simultaneously monitored fields: ≤ 4 1); Number of fields: 128; Number of monitoring cases: 128; Scanning angle: 275°; Resolution (can be configured): 30 mm40 mm50 mm60 mm70 mm150 mm200 mm; Angular resolution: 0.1°; Response time: ≥ 115 ms; Protective field supplement: 100 mm; Safety-related parameters: Type: Type...