[siemens_summary]
[catalog_children]
[catalog_search_products]

SICK ⍾ Page 1420

Product detailsAdd to RFQ
M4C-SA0430LA10 - Sick
Features: Application: Normal industrial environment; Functional principle: Sender/receiver system; System part: Sender; Scanning range category: Low scanning range; Scanning range: 17 m; Dimension of the light pathMinimum0.5 m ... 15 mTypical0.5 m ... 17 m: Dimension of the light path; Number of beams: 4; Beam separation: 300 mm; Synchronization: Optical synchronisation; Items supplied: Sender; Safety-related parameters: Type: Type 4 (IEC...
Product detailsAdd to RFQ
M4C-SX0430HA10 - Sick
Features: Application: Explosive areas; Ex-approvals: ATEX for gas: II 3G Ex ec op is IIC T4 GcATEX for dust: II 3D Ex tc IIIC T135°C Dc; Functional principle: Sender/receiver system; System part: Sender; Scanning range: 90 m; Dimension of the light pathTypical10 m ... 90 m: Dimension of the light path; Number of beams: 4; Beam separation: 300 mm; Response...
Product detailsAdd to RFQ
M4C-SX0250HA10 - Sick
Features: Application: Explosive areas; Ex-approvals: ATEX for gas: II 3G Ex ec op is IIC T4 GcATEX for dust: II 3D Ex tc IIIC T135°C Dc; Functional principle: Sender/receiver system; System part: Sender; Scanning range: 90 m; Dimension of the light pathTypical10 m ... 90 m: Dimension of the light path; Number of beams: 2; Beam separation: 500 mm; Response...
Product detailsAdd to RFQ
M4C-SX0340LA10 - Sick
Features: Application: Explosive areas; Ex-approvals: ATEX for gas: II 3G Ex ec op is IIC T4 GcATEX for dust: II 3D Ex tc IIIC T135°C Dc; Functional principle: Sender/receiver system; System part: Sender; Scanning range: 17 m; Dimension of the light pathTypical0.5 m ... 17 m: Dimension of the light path; Number of beams: 3; Beam separation: 400 mm; Response...
Product detailsAdd to RFQ
M8 4-PIN MALE BUS CONNECTION PLUG - Sick
Technical specifications: Accessory group: Plug connectors and cables; Accessory family: Other connectors and cables; Connection type head A: Male connector, M8, 4-pin, straight, B-coded; Special feature: Terminal resistor FlexChain; Ambient operating temperatureHead–40 °C ... +85 °C: Ambient operating temperature; Classifications: ECl@ss 5.0: 27279201; ECl@ss 5.1.4: 27279201; ECl@ss 6.0: 27279201; ECl@ss 6.2: 27279201; ECl@ss 7.0: 27279201; ECl@ss 8.0: 27279201; ECl@ss 8.1:...
Product detailsAdd to RFQ
M4C-EA03400A10 - Sick
Features: Application: Normal industrial environment; Functional principle: Sender/receiver system; System part: Receiver; Number of beams: 3; Beam separation: 400 mm; Response time: 20 ms; Synchronization: Optical synchronisation; Items supplied: ReceiverSafety instructionMounting instructionsOperating instructions for download; Safety-related parameters: Type: Type 4 (IEC 61496-1); Safety integrity level: SIL3 (IEC 61508)SILCL3 (IEC 62061); Category: Category 4 (ISO 13849-1); Performance level: PL e (ISO...
Product detailsAdd to RFQ
M4C-EA02500A10 - Sick
Features: Application: Normal industrial environment; Functional principle: Sender/receiver system; System part: Receiver; Number of beams: 2; Beam separation: 500 mm; Response time: 20 ms; Synchronization: Optical synchronisation; Items supplied: ReceiverSafety instructionMounting instructionsOperating instructions for download; Safety-related parameters: Type: Type 4 (IEC 61496-1); Safety integrity level: SIL3 (IEC 61508)SILCL3 (IEC 62061); Category: Category 4 (ISO 13849-1); Performance level: PL e (ISO...
Product detailsAdd to RFQ
M4C-SX0340HA10 - Sick
Features: Application: Explosive areas; Ex-approvals: ATEX for gas: II 3G Ex ec op is IIC T4 GcATEX for dust: II 3D Ex tc IIIC T135°C Dc; Functional principle: Sender/receiver system; System part: Sender; Scanning range: 90 m; Dimension of the light pathTypical10 m ... 90 m: Dimension of the light path; Number of beams: 3; Beam separation: 400 mm; Response...
Product detailsAdd to RFQ
M45Z-043000FL0 , PSI02-2302 - Sick
Designation: M4000 Standard A/P in IP69K Housing, including 15 m cable. Number of beams: 4.
Product detailsAdd to RFQ
M4C-SA0250HA10 - Sick
Features: Application: Normal industrial environment; Functional principle: Sender/receiver system; System part: Sender; Scanning range category: Great scanning range; Scanning range: 90 m; Dimension of the light pathMinimum10 m ... 70 mTypical10 m ... 90 m: Dimension of the light path; Number of beams: 2; Beam separation: 500 mm; Synchronization: Optical synchronisation; Items supplied: Sender; Safety-related parameters: Type: Type 4 (IEC...
Product detailsAdd to RFQ
M4C-EX03400A10 - Sick
Features: Application: Explosive areas; Ex-approvals: ATEX for gas: II 3G Ex ec op is IIC T4 GcATEX for dust: II 3D Ex tc IIIC T135°C Dc; Functional principle: Sender/receiver system; System part: Receiver; Number of beams: 3; Beam separation: 400 mm; Response time: 20 ms; Synchronization: Optical synchronisation; Items supplied: Receiver“Notes for explosion protection” label(s)Safety instructionMounting instructionsOperating instructions for download;...
Product detailsAdd to RFQ
M4C-EA04300A10 - Sick
Features: Application: Normal industrial environment; Functional principle: Sender/receiver system; System part: Receiver; Number of beams: 4; Beam separation: 300 mm; Response time: 20 ms; Synchronization: Optical synchronisation; Items supplied: ReceiverSafety instructionMounting instructionsOperating instructions for download; Safety-related parameters: Type: Type 4 (IEC 61496-1); Safety integrity level: SIL3 (IEC 61508)SILCL3 (IEC 62061); Category: Category 4 (ISO 13849-1); Performance level: PL e (ISO...