Skip to content
About Us
Select Brand
ABB
Schneider
Phoneix Contact
Siemens
Innomotics
Weidmuller
Gewiss
Fluke
SICK
Baumer
Dungs
Krom schroder
Festo
Norgren
Foxboro
Telemecanique
IFM
Pilz
Contact Us
About Us
Select Brand
ABB
Schneider
Phoneix Contact
Siemens
Innomotics
Weidmuller
Gewiss
Fluke
SICK
Baumer
Dungs
Krom schroder
Festo
Norgren
Foxboro
Telemecanique
IFM
Pilz
Contact Us
RFQ
Catalog
>
SICK
[siemens_summary]
[catalog_children]
[catalog_search_products]
SICK
Items 18013 - 18024 of 34482
⍾ Last modified Sep 4, 2025
Accessories
Automation Light Grids
Distance Sensors
Encoders
Fibre-optic cables
Fluid sensors
Identification Solutions
Inertial sensors
Laser scanners
Magnetic Cylinder Sensors
Motor feedback systems
Optical data transmission
Opto-Electronic Protective Devices
Photoelectric / Fiber-optics sensors
Proximity sensors
Registration Sensors
Safety Switches
sens:Control - Safe Control Solutions
Vision
Search
SICK ⍾ Page 1502
«
1
…
1,500
1,501
1,502
1,503
1,504
…
2,874
»
Product details
Add to RFQ
LFV310-XXTAPX8CX - Sick
Features: Medium: Fluids; Measurement: Switch; Probe length: 66 mm; Process pressure: –1 bar ... 64 bar; Process temperature: –50 °C ... +150 °C; Fill material density: 0.5 g/cm³ ... 2.5 g/cm³; EHEDG approval: ✔; Performance: Accuracy of sensor element: ± 2 mm; Reproducibility: ≤ 1 mm; Viscosity: 0.1 mPas ... 10,000 mPas; Response time: 500 ms; Electronics: Power consumption: <...
Product details
Add to RFQ
LFV330-CAADVXMN0250 - Sick
Vibrating level switch, LFV330. Probe length / Detection range: 250 mm. Process pressure: -1 bar ... 64 bar. Process temperature: -50 °C ... 150 °C. Housing material: Aluminum.
Product details
Add to RFQ
LFV330-CAADVTMN0250 - Sick
Vibrating level switch, LFV330. Probe length / Detection range: 250 mm. Process pressure: -1 bar ... 64 bar. Process temperature: -50 °C ... 250 °C. Housing material: Aluminum.
Product details
Add to RFQ
LFV310-XXTNPX8CX - Sick
Features: Medium: Fluids; Measurement: Switch; Probe length: 66 mm; Process pressure: –1 bar ... 64 bar; Process temperature: –50 °C ... +150 °C; Fill material density: 0.5 g/cm³ ... 2.5 g/cm³; EHEDG approval: ✔; Performance: Accuracy of sensor element: ± 2 mm; Reproducibility: ≤ 1 mm; Viscosity: 0.1 mPas ... 10,000 mPas; Response time: 500 ms; Electronics: Power consumption: <...
Product details
Add to RFQ
LFV310-XXTNPX9TX - Sick
Features: Medium: Fluids; Measurement: Switch; Probe length: 66 mm; Process pressure: –1 bar ... 64 bar; Process temperature: –50 °C ... +150 °C; Fill material density: 0.5 g/cm³ ... 2.5 g/cm³; EHEDG approval: ✔; Performance: Accuracy of sensor element: ± 2 mm; Reproducibility: ≤ 1 mm; Viscosity: 0.1 mPas ... 10,000 mPas; Response time: 500 ms; Electronics: Residual ripple: ≤...
Product details
Add to RFQ
LFV310-XXRAPXVRX - Sick
Features: Medium: Fluids; Measurement: Switch; Probe length: 66 mm; Process pressure: –1 bar ... 64 bar; Process temperature: –50 °C ... +150 °C; Fill material density: 0.5 g/cm³ ... 2.5 g/cm³; Performance: Accuracy of sensor element: ± 2 mm; Reproducibility: ≤ 1 mm; Viscosity: 0.1 mPas ... 10,000 mPas; Response time: 500 ms; Electronics: Power consumption: 5 mA ... 30...
Product details
Add to RFQ
LFV330-CAAPVXPNX0250 - Sick
Vibrating level switch, LFV330. Probe length / Detection range: 250 mm. Process pressure: -1 bar ... 64 bar. Process temperature: -50 °C ... 150 °C. Housing material: Plastic.
Product details
Add to RFQ
LFV310-XXRAPX8RX - Sick
Features: Medium: Fluids; Measurement: Switch; Probe length: 66 mm; Process pressure: –1 bar ... 64 bar; Process temperature: –50 °C ... +150 °C; Fill material density: 0.5 g/cm³ ... 2.5 g/cm³; Performance: Accuracy of sensor element: ± 2 mm; Reproducibility: ≤ 1 mm; Viscosity: 0.1 mPas ... 10,000 mPas; Response time: 500 ms; Electronics: Power consumption: 5 mA ... 30...
Product details
Add to RFQ
LFV310-XXRAPX8TX - Sick
Features: Medium: Fluids; Measurement: Switch; Probe length: 66 mm; Process pressure: –1 bar ... 64 bar; Process temperature: –50 °C ... +150 °C; Fill material density: 0.5 g/cm³ ... 2.5 g/cm³; Performance: Accuracy of sensor element: ± 2 mm; Reproducibility: ≤ 1 mm; Viscosity: 0.1 mPas ... 10,000 mPas; Response time: 500 ms; Electronics: Residual ripple: ≤ 5 Vpp; Power...
Product details
Add to RFQ
LFV310-XXNAVXMRX - Sick
Features: Medium: Fluids; Measurement: Switch; Probe length: 66 mm; Process pressure: –1 bar ... 64 bar; Process temperature: –50 °C ... +150 °C; Fill material density: 0.5 g/cm³ ... 2.5 g/cm³; Performance: Accuracy of sensor element: ± 2 mm; Reproducibility: ≤ 1 mm; Viscosity: 0.1 mPas ... 10,000 mPas; Response time: 500 ms; Electronics: Power consumption: 5 mA ... 30...
Product details
Add to RFQ
LFV310-XXNAVXUTX - Sick
Features: Medium: Fluids; Measurement: Switch; Probe length: 66 mm; Process pressure: –1 bar ... 64 bar; Process temperature: –50 °C ... +150 °C; Fill material density: 0.5 g/cm³ ... 2.5 g/cm³; Performance: Accuracy of sensor element: ± 2 mm; Reproducibility: ≤ 1 mm; Viscosity: 0.1 mPas ... 10,000 mPas; Response time: 500 ms; Electronics: Residual ripple: ≤ 5 Vpp; Power...
Product details
Add to RFQ
LFV310-XXNBVX8RX - Sick
Features: Medium: Fluids; Measurement: Switch; Probe length: 66 mm; Process pressure: –1 bar ... 64 bar; Process temperature: –50 °C ... +150 °C; Fill material density: 0.5 g/cm³ ... 2.5 g/cm³; Performance: Accuracy of sensor element: ± 2 mm; Reproducibility: ≤ 1 mm; Viscosity: 0.1 mPas ... 10,000 mPas; Response time: 500 ms; Electronics: Power consumption: 5 mA ... 30...
« Prev page
Next page »