[siemens_summary]
[catalog_children]
[catalog_search_products]

SICK ⍾ Page 1927

Product detailsAdd to RFQ
ELG1-0100P531 - Sick
ELG, ELG Short Range. Detection height: 100 mm. Beam separation: 10 mm. Output type: 2 x PNP (Q and /Q). Connection type: Connector M12, 4-pin.
Product detailsAdd to RFQ
E100-A2A22S25A - Sick
Enabling switch, E100. Number of positive action N/C contacts: 2. Number of N/O contacts: 2.
Product detailsAdd to RFQ
E100-B2A22S10A - Sick
Enabling switch, E100. Number of positive action N/C contacts: 2. Number of N/O contacts: 2.
Product detailsAdd to RFQ
ELG1-0150P531 - Sick
ELG, ELG Short Range. Detection height: 150 mm. Beam separation: 10 mm. Output type: 2 x PNP (Q and /Q). Connection type: Connector M12, 4-pin.
Product detailsAdd to RFQ
ELG1-0150N533 - Sick
ELG, ELG Short Range. Detection height: 150 mm. Beam separation: 10 mm. Output type: 2 x NPN (Q and /Q). Connection type: Connector M12, 4-pin.
Product detailsAdd to RFQ
E100-B2A22S05A - Sick
Enabling switch, E100. Number of positive action N/C contacts: 2. Number of N/O contacts: 2.
Product detailsAdd to RFQ
DUV60E-D4KMHADA - Sick
Performance: Linear resolution: 0.125 mm/pulse to 304.8 mm/pulse (type-dependent); Pulses per revolution: 1 ... 1500 1); Measuring step: 90° electric/pulses per revolution; Measuring increment (resolution in mm/pulse): / pulses per revolution; Measuring step deviation: ± 18°, / pulses per revolution; Error limits: Measuring step deviation x 3; Duty cycle: 0.5 ± 5 %; Initialization time: < 5 ms 2); Interfaces:...
Product detailsAdd to RFQ
DUV60E-D4KKHBGA - Sick
Performance: Linear resolution: 0.125 mm/pulse to 304.8 mm/pulse (type-dependent); Pulses per revolution: 1 ... 48 1); Measuring step: 90° electric/pulses per revolution; Measuring increment (resolution in mm/pulse): / pulses per revolution; Measuring step deviation: ± 18°, / pulses per revolution; Error limits: Measuring step deviation x 3; Duty cycle: 0.5 ± 5 %; Initialization time: < 5 ms 2); Interfaces:...
Product detailsAdd to RFQ
DUV60E-D4KKHADA - Sick
Performance: Linear resolution: 0.125 mm/pulse to 304.8 mm/pulse (type-dependent); Pulses per revolution: 1 ... 1500 1); Measuring step: 90° electric/pulses per revolution; Measuring increment (resolution in mm/pulse): / pulses per revolution; Measuring step deviation: ± 18°, / pulses per revolution; Error limits: Measuring step deviation x 3; Duty cycle: 0.5 ± 5 %; Initialization time: < 5 ms 2); Interfaces:...
Product detailsAdd to RFQ
E100-A2A22S10A - Sick
Enabling switch, E100. Number of positive action N/C contacts: 2. Number of N/O contacts: 2.
Product detailsAdd to RFQ
DUV60E-D4KFWDGB - Sick
Performance: Linear resolution: 0.125 mm/pulse to 304.8 mm/pulse (type-dependent); Pulses per revolution: 1 ... 48 1); Measuring step: 90° electric/pulses per revolution; Measuring increment (resolution in mm/pulse): / pulses per revolution; Measuring step deviation: ± 18°, / pulses per revolution; Error limits: Measuring step deviation x 3; Duty cycle: 0.5 ± 5 %; Initialization time: < 5 ms 2); Interfaces:...
Product detailsAdd to RFQ
DUV60E-D4KZHAZAS01 - Sick
Features: Special device: ✔; Specialty: MS 6-pin connector at the end of a 1.5 m cable, DIP switches pre-set to HTL output; Standard reference device: DUV60E-D4KKHADA, 1085779; Performance: Linear resolution: 0.125 mm/pulse to 304.8 mm/pulse (type-dependent); Pulses per revolution: 1 ... 1500 1); Measuring step: 90° electric/pulses per revolution; Measuring increment (resolution in mm/pulse): / pulses per revolution; Measuring step...