Skip to content
About Us
Select Brand
ABB
Schneider
Phoneix Contact
Siemens
Innomotics
Weidmuller
Gewiss
Fluke
SICK
Baumer
Dungs
Krom schroder
Festo
Norgren
Foxboro
Telemecanique
IFM
Pilz
Contact Us
About Us
Select Brand
ABB
Schneider
Phoneix Contact
Siemens
Innomotics
Weidmuller
Gewiss
Fluke
SICK
Baumer
Dungs
Krom schroder
Festo
Norgren
Foxboro
Telemecanique
IFM
Pilz
Contact Us
RFQ
Catalog
>
SICK
[siemens_summary]
[catalog_children]
[catalog_search_products]
SICK
Items 24757 - 24768 of 34482
⍾ Last modified Sep 4, 2025
Accessories
Automation Light Grids
Distance Sensors
Encoders
Fibre-optic cables
Fluid sensors
Identification Solutions
Inertial sensors
Laser scanners
Magnetic Cylinder Sensors
Motor feedback systems
Optical data transmission
Opto-Electronic Protective Devices
Photoelectric / Fiber-optics sensors
Proximity sensors
Registration Sensors
Safety Switches
sens:Control - Safe Control Solutions
Vision
Search
SICK ⍾ Page 2064
«
1
…
2,062
2,063
2,064
2,065
2,066
…
2,874
»
Product details
Add to RFQ
DFV60A-22PM65536 - Sick
DFV60 measuring wheel encoder. Electrical interface: 4.5 V ... 5.5 V, TTL/HTL programmable, Cable, universal, 5 m.
Product details
Add to RFQ
DFS60S-THOK01024 - Sick
Safety-related parameters: Safety integrity level: SIL2 (IEC 61508), SILCL2 (IEC 62061) 1); Performance level: PL d (EN ISO 13849) 1); Category: 3 (EN ISO 13849); PFHD: Probability of dangerous failure per hour: 1.7 x 10-8 2); TM (mission time): 20 years (EN ISO 13849); Safety-related measuring step: 0.09°, Quadrature analysis; Safety-related accuracy: ± 0.09°; Performance: Sine/cosine periods per revolution: 1,024;...
Product details
Add to RFQ
DFS60S-THOA01024 - Sick
Safety-related parameters: Safety integrity level: SIL2 (IEC 61508), SILCL2 (IEC 62061) 1); Performance level: PL d (EN ISO 13849) 1); Category: 3 (EN ISO 13849); PFHD: Probability of dangerous failure per hour: 1.7 x 10-8 2); TM (mission time): 20 years (EN ISO 13849); Safety-related measuring step: 0.09°, Quadrature analysis; Safety-related accuracy: ± 0.09°; Performance: Sine/cosine periods per revolution: 1,024;...
Product details
Add to RFQ
DFS60S-TGOM01024 - Sick
Safety-related parameters: Safety integrity level: SIL2 (IEC 61508), SILCL2 (IEC 62061) 1); Performance level: PL d (EN ISO 13849) 1); Category: 3 (EN ISO 13849); PFHD: Probability of dangerous failure per hour: 1.7 x 10-8 2); TM (mission time): 20 years (EN ISO 13849); Safety-related measuring step: 0.09°, Quadrature analysis; Safety-related accuracy: ± 0.09°; Performance: Sine/cosine periods per revolution: 1,024;...
Product details
Add to RFQ
DFV60A-22PC65536 - Sick
DFV60 measuring wheel encoder. Electrical interface: 4.5 V ... 5.5 V, TTL/HTL programmable, Connector, M12, 8-pin, radial.
Product details
Add to RFQ
DFS60S-TBOK01024 - Sick
Safety-related parameters: Safety integrity level: SIL2 (IEC 61508), SILCL2 (IEC 62061) 1); Performance level: PL d (EN ISO 13849) 1); Category: 3 (EN ISO 13849); PFHD: Probability of dangerous failure per hour: 1.7 x 10-8 2); TM (mission time): 20 years (EN ISO 13849); Safety-related measuring step: 0.09°, Quadrature analysis; Safety-related accuracy: ± 0.09°; Performance: Sine/cosine periods per revolution: 1,024;...
Product details
Add to RFQ
DFS60S-TCOJ01024 - Sick
Safety-related parameters: Safety integrity level: SIL2 (IEC 61508), SILCL2 (IEC 62061) 1); Performance level: PL d (EN ISO 13849) 1); Category: 3 (EN ISO 13849); PFHD: Probability of dangerous failure per hour: 1.7 x 10-8 2); TM (mission time): 20 years (EN ISO 13849); Safety-related measuring step: 0.09°, Quadrature analysis; Safety-related accuracy: ± 0.09°; Performance: Sine/cosine periods per revolution: 1,024;...
Product details
Add to RFQ
DFS60S-TGOC01024 - Sick
Safety-related parameters: Safety integrity level: SIL2 (IEC 61508), SILCL2 (IEC 62061) 1); Performance level: PL d (EN ISO 13849) 1); Category: 3 (EN ISO 13849); PFHD: Probability of dangerous failure per hour: 1.7 x 10-8 2); TM (mission time): 20 years (EN ISO 13849); Safety-related measuring step: 0.09°, Quadrature analysis; Safety-related accuracy: ± 0.09°; Performance: Sine/cosine periods per revolution: 1,024;...
Product details
Add to RFQ
DFS60S-THOM01024 - Sick
Safety-related parameters: Safety integrity level: SIL2 (IEC 61508), SILCL2 (IEC 62061) 1); Performance level: PL d (EN ISO 13849) 1); Category: 3 (EN ISO 13849); PFHD: Probability of dangerous failure per hour: 1.7 x 10-8 2); TM (mission time): 20 years (EN ISO 13849); Safety-related measuring step: 0.09°, Quadrature analysis; Safety-related accuracy: ± 0.09°; Performance: Sine/cosine periods per revolution: 1,024;...
Product details
Add to RFQ
DFS60S-TGOA01024 - Sick
Safety-related parameters: Safety integrity level: SIL2 (IEC 61508), SILCL2 (IEC 62061) 1); Performance level: PL d (EN ISO 13849) 1); Category: 3 (EN ISO 13849); PFHD: Probability of dangerous failure per hour: 1.7 x 10-8 2); TM (mission time): 20 years (EN ISO 13849); Safety-related measuring step: 0.09°, Quadrature analysis; Safety-related accuracy: ± 0.09°; Performance: Sine/cosine periods per revolution: 1,024;...
Product details
Add to RFQ
DFS60S-SEOK01024 - Sick
Safety-related parameters: Safety integrity level: SIL2 (IEC 61508), SILCL2 (IEC 62061) 1); Performance level: PL d (EN ISO 13849) 1); Category: 3 (EN ISO 13849); PFHD: Probability of dangerous failure per hour: 1.7 x 10-8 2); TM (mission time): 20 years (EN ISO 13849); Safety-related measuring step: 0.09°, Quadrature analysis; Safety-related accuracy: ± 0.09°; Performance: Sine/cosine periods per revolution: 1,024;...
Product details
Add to RFQ
DFS60S-TDOA01024 - Sick
Safety-related parameters: Safety integrity level: SIL2 (IEC 61508), SILCL2 (IEC 62061) 1); Performance level: PL d (EN ISO 13849) 1); Category: 3 (EN ISO 13849); PFHD: Probability of dangerous failure per hour: 1.7 x 10-8 2); TM (mission time): 20 years (EN ISO 13849); Safety-related measuring step: 0.09°, Quadrature analysis; Safety-related accuracy: ± 0.09°; Performance: Sine/cosine periods per revolution: 1,024;...