DFS60B-TJEC10000 - Sick
Performance: Pulses per revolution: 10,000 1); Measuring step: 90° electronically/ppr; Measuring step deviation at non binary number of lines: ± 0.01°; Error limits: ± 0.05°; Interfaces: Communication interface: Incremental; Communication Interface detail: HTL / Push pull; Number of signal channels: 6-channel; Initialization time: 40 ms; Output frequency: ≤ 600 kHz; Load current: ≤ 30 mA; Power consumption: ≤ 0.5 W...
Product detailsAdd to RFQ
DFS60B-TJAC01024 - Sick
Performance: Pulses per revolution: 1,024 1); Measuring step: 90° electronically/ppr; Measuring step deviation at binary number of lines: ± 0.008°; Error limits: ± 0.05°; Interfaces: Communication interface: Incremental; Communication Interface detail: TTL / RS-422; Number of signal channels: 6-channel; Initialization time: 40 ms; Output frequency: ≤ 600 kHz; Load current: ≤ 30 mA; Operating current: 40 mA (without load); Electrical...
Product detailsAdd to RFQ
DFS60B-TJAK08192 - Sick
Performance: Pulses per revolution: 8,192 1); Measuring step: 90° electronically/ppr; Measuring step deviation at binary number of lines: ± 0.008°; Error limits: ± 0.05°; Interfaces: Communication interface: Incremental; Communication Interface detail: TTL / RS-422; Number of signal channels: 6-channel; Initialization time: 40 ms; Output frequency: ≤ 600 kHz; Load current: ≤ 30 mA; Operating current: 40 mA (without load); Electrical...
Product detailsAdd to RFQ
DFS60B-TJNC01024 - Sick
Performance: Periods per revolution: 1,024; Measuring step: 90° electronically/ppr; Measuring step deviation at binary number of lines: ± 0.008°; Error limits: ± 0.05°; Interfaces: Communication interface: Incremental; Communication Interface detail: Sin/Cos 1); Number of signal channels: 6-channel; Initialization time: 40 ms; Output frequency: ≤ 200 kHz; Operating current: 40 mA (without load); Load resistance: ≤ 120 Ω; Electrical data: Connection...
Product detailsAdd to RFQ
DFS60B-TJEC01024 - Sick
Performance: Pulses per revolution: 1,024 1); Measuring step: 90° electronically/ppr; Measuring step deviation at binary number of lines: ± 0.008°; Error limits: ± 0.05°; Interfaces: Communication interface: Incremental; Communication Interface detail: HTL / Push pull; Number of signal channels: 6-channel; Initialization time: 40 ms; Output frequency: ≤ 600 kHz; Load current: ≤ 30 mA; Power consumption: ≤ 0.5 W (without...
Product detailsAdd to RFQ
DFS60B-TJAA10000 - Sick
Performance: Pulses per revolution: 10,000 1); Measuring step: 90° electronically/ppr; Measuring step deviation at non binary number of lines: ± 0.01°; Error limits: ± 0.05°; Interfaces: Communication interface: Incremental; Communication Interface detail: TTL / RS-422; Number of signal channels: 6-channel; Initialization time: 40 ms; Output frequency: ≤ 600 kHz; Load current: ≤ 30 mA; Operating current: 40 mA (without load);...
Product detailsAdd to RFQ
DFS60B-THWA00377 - Sick
Performance: Pulses per revolution: 377 1); Measuring step: 90° electronically/ppr; Measuring step deviation at non binary number of lines: ± 0.01°; Error limits: ± 0.05°; Interfaces: Communication interface: Incremental; Communication Interface detail: HTL / Push pull; Number of signal channels: 6-channel; 0-set function via hardware pin: ✔; 0-SET function: H-active, L = 0 - 3 V, H = 4,0 -...
Product detailsAdd to RFQ
DFS60B-THVA04096 - Sick
Performance: Pulses per revolution: 4,096 1); Measuring step: 90° electronically/ppr; Measuring step deviation at binary number of lines: ± 0.008°; Error limits: ± 0.05°; Interfaces: Communication interface: Incremental; Communication Interface detail: TTL / RS-422; Number of signal channels: 6-channel; 0-set function via hardware pin: ✔; 0-SET function: H-active, L = 0 - 3 V, H = 4,0 - Us V...
Product detailsAdd to RFQ
DFS60B-THPZ00S90 - Sick
Features: Special device: ✔; Specialty: Cable, 8-wire, 10 m with customized cable end (doubling signal B and B_)4.5…32 V, TTL/HTL programmable, preprogrammed to HTLProgrammable resolution up to 10 000 linesAdditional customized type labels, details find on page 5; Standard reference device: DFS60B-THPN1000, 1062711; Additional information: Customer project BAA633B2; Performance: Pulses per revolution: 10,000 1); Measuring step: 90° electronically/ppr; Measuring step...
Product detailsAdd to RFQ
DFS60B-THPC10000 - Sick
DFS60, Rotary. Electrical interface: 4.5 V ... 32 V, TTL/HTL programmable, Connector M12, 8-pin, radial.
Product detailsAdd to RFQ
DFS60B-THPN10000 - Sick
Performance: Pulses per revolution: 10,000 1); Measuring step: 90° electronically/ppr; Measuring step deviation at non binary number of lines: ± 0.01°; Error limits: ± 0.05°; Interfaces: Communication interface: Incremental; Communication Interface detail: TTL / HTL; Factory setting: Factory setting: output level TTL; Number of signal channels: 6-channel; Programmable/configurable: ✔; Initialization time: 32 ms 1)30 ms; Output frequency: ≤ 600 kHz;...
Product detailsAdd to RFQ
DFS60B-THPZ00S76 - Sick
Features: Special device: ✔; Specialty: Without cable connection; Standard reference device: DFS60B-THPK01024, 1076210; Performance: Pulses per revolution: 1,024 1); Measuring step: 90° electronically/ppr; Measuring step deviation at binary number of lines: ± 0.008°; Error limits: ± 0.05°; Interfaces: Communication interface: Incremental; Communication Interface detail: TTL / HTL; Factory setting: Factory setting: output level TTL; Number of signal channels: 6-channel; Programmable/configurable:...