[siemens_summary]
[catalog_children]
[catalog_search_products]

SICK ⍾ Page 2145

Product detailsAdd to RFQ
DFS60B-T5AK03600 - Sick
Performance: Pulses per revolution: 3,600 1); Measuring step: 90° electronically/ppr; Measuring step deviation at non binary number of lines: ± 0.01°; Error limits: ± 0.05°; Interfaces: Communication interface: Incremental; Communication Interface detail: TTL / RS-422; Number of signal channels: 6-channel; Initialization time: 40 ms; Output frequency: ≤ 600 kHz; Load current: ≤ 30 mA; Operating current: 40 mA (without load);...
Product detailsAdd to RFQ
DFS60B-S4WB00360 - Sick
Performance: Pulses per revolution: 360 1); Measuring step: 90° electronically/ppr; Measuring step deviation at non binary number of lines: ± 0.01°; Error limits: ± 0.05°; Interfaces: Communication interface: Incremental; Communication Interface detail: HTL / Push pull; Number of signal channels: 6-channel; 0-set function via hardware pin: ✔; 0-SET function: H-active, L = 0 - 3 V, H = 4,0 -...
Product detailsAdd to RFQ
DFS60B-S4WB01000 - Sick
DFS60, Rotary. Electrical interface: 10 V ... 32 V, HTL/Push pull, 0-SET, Connector M23, 12-pin, axial.
Product detailsAdd to RFQ
DFS60B-S4WB00640 - Sick
DFS60, Rotary. Electrical interface: 10 V ... 32 V, HTL/Push pull, 0-SET, Connector M23, 12-pin, axial.
Product detailsAdd to RFQ
DFS60B-S4WB05000 - Sick
DFS60, Rotary. Electrical interface: 10 V ... 32 V, HTL/Push pull, 0-SET, Connector M23, 12-pin, axial.
Product detailsAdd to RFQ
DFS60B-S4WB00030 - Sick
Performance: Pulses per revolution: 30 1); Measuring step: 90° electronically/ppr; Measuring step deviation at non binary number of lines: ± 0.08°; Error limits: ± 0.05°; Interfaces: Communication interface: Incremental; Communication Interface detail: HTL / Push pull; Number of signal channels: 6-channel; 0-set function via hardware pin: ✔; 0-SET function: H-active, L = 0 - 3 V, H = 4,0 -...
Product detailsAdd to RFQ
DFS60B-S4WB00050 - Sick
Performance: Pulses per revolution: 50 1); Measuring step: 90° electronically/ppr; Measuring step deviation at non binary number of lines: ± 0.08°; Error limits: ± 0.05°; Interfaces: Communication interface: Incremental; Communication Interface detail: HTL / Push pull; Number of signal channels: 6-channel; 0-set function via hardware pin: ✔; 0-SET function: H-active, L = 0 - 3 V, H = 4,0 -...
Product detailsAdd to RFQ
DFS60B-S4WB00005 - Sick
Performance: Pulses per revolution: 5 1); Measuring step: 90° electronically/ppr; Measuring step deviation at non binary number of lines: ± 0.08°; Error limits: ± 0.05°; Interfaces: Communication interface: Incremental; Communication Interface detail: HTL / Push pull; Number of signal channels: 6-channel; 0-set function via hardware pin: ✔; 0-SET function: H-active, L = 0 - 3 V, H = 4,0 -...
Product detailsAdd to RFQ
DFS60B-S4WB08192 - Sick
DFS60, Rotary. Electrical interface: 10 V ... 32 V, HTL/Push pull, 0-SET, Connector M23, 12-pin, axial.
Product detailsAdd to RFQ
DFS60B-S4WA07200 - Sick
Performance: Pulses per revolution: 7,200 1); Measuring step: 90° electronically/ppr; Measuring step deviation at non binary number of lines: ± 0.01°; Error limits: ± 0.05°; Interfaces: Communication interface: Incremental; Communication Interface detail: HTL / Push pull; Number of signal channels: 6-channel; 0-set function via hardware pin: ✔; 0-SET function: H-active, L = 0 - 3 V, H = 4,0 -...
Product detailsAdd to RFQ
DFS60B-S4WA04096 - Sick
Performance: Pulses per revolution: 4,096 1); Measuring step: 90° electronically/ppr; Measuring step deviation at binary number of lines: ± 0.008°; Error limits: ± 0.05°; Interfaces: Communication interface: Incremental; Communication Interface detail: HTL / Push pull; Number of signal channels: 6-channel; 0-set function via hardware pin: ✔; 0-SET function: H-active, L = 0 - 3 V, H = 4,0 - Us...
Product detailsAdd to RFQ
DFS60B-S4WB00002 - Sick
DFS60, Rotary. Electrical interface: 10 V ... 32 V, HTL/Push pull, 0-SET, Connector M23, 12-pin, axial.