[siemens_summary]
[catalog_children]
[catalog_search_products]

SICK ⍾ Page 371

Product detailsAdd to RFQ
TR4-SAM03PB - Sick
Features: System part: Sensor and actuator; Sensor principle: Transponder; Number of safe outputs: 2; Safe switch on distance Sao: 15 mm; Safe switch off distance Sar: 25 mm; Active sensor surfaces: 2; Actuation directions: 5; Coding: Universally coded; Safety-related parameters: Safety integrity level: SIL3 (IEC 61508)SILCL3 (EN 62061); Category: Category 4 (EN ISO 13849); Performance level: PL e (EN ISO...
Product detailsAdd to RFQ
TR4-SAM03P - Sick
TR4 Direct Sensor & actuator. Product family: TR4 Direct. System part: Sensor & actuator. Connection type: Cable. Cable length: 3 m.
Product detailsAdd to RFQ
TMS88B-ACC360 - Sick
Performance: Number of axis: 1; Measuring range: 360°; Resolution: 0.01°; Accuracy: Typ. ± 0.15°, max. ± 0.25°; Temperature coefficient (zero point): Typ. ±0.008°/K 1); Limit frequency: 0.1 Hz ... 25 Hz, 8. range (with digital filter); Sampling rate: 80 Hz; Initialization time: 80 ms; Interfaces: Communication interface: CANopen; Device profile: CiA DS-301, DS-410 v4.2.0CiA (Device profile for inclination sensors)CiA DSP-305...
Product detailsAdd to RFQ
TMS88B-PKC360 - Sick
Performance: Number of axis: 1; Measuring range: 360°; Resolution: 0.01°; Accuracy: Typ. ± 0.15°, max. ± 0.25°; Temperature coefficient (zero point): Typ. ±0.01°/K 1); Limit frequency: 0.1 Hz ... 25 Hz, 8. range (with digital filter); Sampling rate: 80 Hz; Initialization time: 265 ms; Interfaces: Communication interface: Analog / 4...20 mA; Load resistance max,: 850 Ω 1); Parameterising data: Measuring...
Product detailsAdd to RFQ
TMS88B-PLC360 - Sick
Performance: Number of axis: 1; Measuring range: 360°; Resolution: 0.01°; Accuracy: Typ. ± 0.15°, max. ± 0.25°; Temperature coefficient (zero point): Typ. ±0.01°/K 1); Limit frequency: 0.1 Hz ... 25 Hz, 8. range (with digital filter); Sampling rate: 80 Hz; Initialization time: 270 ms; Interfaces: Communication interface: Analog / 0...10 V; Parameterising data: Measuring rangeZerosetLimit frequencyPreset valueInverting of counting directionAxis...
Product detailsAdd to RFQ
TMS88B-AKC360 - Sick
Performance: Number of axis: 1; Measuring range: 360°; Resolution: 0.01°; Accuracy: Typ. ± 0.15°, max. ± 0.25°; Temperature coefficient (zero point): Typ. ±0.01°/K 1); Limit frequency: 0.1 Hz ... 25 Hz, 8. range (with digital filter); Sampling rate: 80 Hz; Initialization time: 265 ms; Interfaces: Communication interface: Analog / 4...20 mA; Load resistance max,: 850 Ω 1); Parameterising data: Measuring...
Product detailsAdd to RFQ
TMS88B-ALC360 - Sick
Performance: Number of axis: 1; Measuring range: 360°; Resolution: 0.01°; Accuracy: Typ. ± 0.15°, max. ± 0.25°; Temperature coefficient (zero point): Typ. ±0.01°/K 1); Limit frequency: 0.1 Hz ... 25 Hz, 8. range (with digital filter); Sampling rate: 80 Hz; Initialization time: 270 ms; Interfaces: Communication interface: Analog / 0...10 V; Parameterising data: Measuring rangeZerosetLimit frequencyPreset valueInverting of counting directionAxis...
Product detailsAdd to RFQ
TMM88B-PLC090 - Sick
Performance: Number of axis: 2; Measuring range: ± 90°; Resolution: 0.01°; Accuracy: ≤ ± 60°, typ. ± 0.1°, max. ± 0.2°≤ ± 80°, typ. ± 0.2°, max. ± 0.4°; Compensated cross-sensitivity (2-dimensional): Typ. ± 0.09°, max. ± 0.45°; Temperature coefficient (zero point): Typ. ±0.01°/K 1); Limit frequency: 0.1 Hz ... 25 Hz, 8. range (with digital filter); Sampling rate: 80...
Product detailsAdd to RFQ
TMS88A-PCI360 - Sick
Performance: Number of axis: 1; Measuring range: 360°; Resolution: 0.01°; Accuracy: Typ. ± 0.04°, max. ± 0.12°; Temperature coefficient (zero point): Typ. ±0.008°/K 1); Limit frequency: 0.1 Hz ... 25 Hz, 8. range (with digital filter); Sampling rate: 80 Hz; Initialization time: 200 ms; Interfaces: Communication interface: CANopen; Device profile: CiA DS-301, DS-410 v4.2.0CiA (Device profile for inclination sensors)CiA DSP-305...
Product detailsAdd to RFQ
TMS88A-PKC360 - Sick
Performance: Number of axis: 1; Measuring range: 360°; Resolution: 0.01°; Accuracy: Typ. ± 0.04°, max. ± 0.12°; Temperature coefficient (zero point): Typ. +0.0088°/K, –0.0102°/K 1); Limit frequency: 0.1 Hz ... 25 Hz, 8. range (with digital filter); Sampling rate: 100 Hz; Initialization time: 330 ms; Interfaces: Communication interface: Analog / 4...20 mA; Load resistance max,: 850 Ω 1); Parameterising data:...
Product detailsAdd to RFQ
TMS88A-PLC360 - Sick
Performance: Number of axis: 1; Measuring range: 360°; Resolution: 0.01°; Accuracy: Typ. ± 0.04°, max. ± 0.12°; Temperature coefficient (zero point): Typ. ±0.0083°/K 1); Limit frequency: 0.1 Hz ... 25 Hz, 8. range (with digital filter); Sampling rate: 100 Hz; Initialization time: 330 ms; Interfaces: Communication interface: Analog / 0...10 V; Parameterising data: Measuring rangeZerosetLimit frequencyPreset valueInverting of counting directionAxis...
Product detailsAdd to RFQ
Tool for front window, Inspector Flex - Sick
Technical specifications: Accessory group: Lenses and accessories; Description: Tool for changing front screen and lens on variants with exchangeable lens and front window; Classifications: ECl@ss 5.0: 21043290; ECl@ss 5.1.4: 21043290; ECl@ss 6.0: 21049090; ECl@ss 6.2: 21049090; ECl@ss 7.0: 21049090; ECl@ss 8.0: 21049090; ECl@ss 8.1: 21049090; ECl@ss 9.0: 21049090; ECl@ss 10.0: 21049090; ECl@ss 11.0: 21049090; ETIM 5.0: EC000163; ETIM 6.0: EC000163;...