[siemens_summary]
[catalog_children]
[catalog_search_products]

SICK ⍾ Page 372

Product detailsAdd to RFQ
Tool for front window, Inspector Flex - Sick
Technical specifications: Accessory group: Lenses and accessories; Description: Tool for changing front screen and lens on variants with exchangeable lens and front window; Classifications: ECl@ss 5.0: 21043290; ECl@ss 5.1.4: 21043290; ECl@ss 6.0: 21049090; ECl@ss 6.2: 21049090; ECl@ss 7.0: 21049090; ECl@ss 8.0: 21049090; ECl@ss 8.1: 21049090; ECl@ss 9.0: 21049090; ECl@ss 10.0: 21049090; ECl@ss 11.0: 21049090; ETIM 5.0: EC000163; ETIM 6.0: EC000163;...
Product detailsAdd to RFQ
TMS88A-PCI360S03 - Sick
Features: Special device: ✔; Specialty: Accuracy: +/- 0.04°; Standard reference device: TMS88A-PCI360, 1073802; Interfaces: Communication interface: CANopen; Ambient data: Resistance to shocks: 100 g, 6 ms (according to EN 60068-2-27); Resistance to vibration: 10 g, 10 Hz ... 2,000 Hz (according to EN 60068-2-6); Classifications: ECl@ss 5.0: 27270790; ECl@ss 5.1.4: 27270790; ECl@ss 6.0: 27270790; ECl@ss 6.2: 27270790; ECl@ss 7.0: 27270790;...
Product detailsAdd to RFQ
TR4-SAM01C - Sick
TR4 Direct Sensor & actuator. Product family: TR4 Direct. System part: Sensor & actuator. Connection type: Cable with plug M12, 8-pin. Cable length: 0.2 m.
Product detailsAdd to RFQ
TIM310-1030000S01 - Sick
TiM3xx / TiM31x / Indoor / Short Range. Scanning frequency: 15 Hz. Operating range: 0.05 m ... 4 m. Field of view: 270 °.
Product detailsAdd to RFQ
TMM88B-ACC090 - Sick
Performance: Number of axis: 2; Measuring range: ± 90°; Resolution: 0.01°; Accuracy: ≤ ± 60°, typ. ± 0.1°, max. ± 0.2°≤ ± 80°, typ. ± 0.2°, max. ± 0.3°; Compensated cross-sensitivity (2-dimensional): Typ. ± 0.09°, max. ± 0.45°; Temperature coefficient (zero point): Typ. ±0.008°/K 1); Limit frequency: 0.1 Hz ... 25 Hz, 8. range (with digital filter); Sampling rate: 80...
Product detailsAdd to RFQ
TMM88B-AKC090 - Sick
Performance: Number of axis: 2; Measuring range: ± 90°; Resolution: 0.01°; Accuracy: ≤ ± 60°, typ. ± 0.1°, max. ± 0.2°≤ ± 80°, typ. ± 0.2°, max. ± 0.4°; Compensated cross-sensitivity (2-dimensional): Typ. ± 0.09°, max. ± 0.45°; Temperature coefficient (zero point): Typ. ±0.01°/K 1); Limit frequency: 0.1 Hz ... 25 Hz, 8. range (with digital filter); Sampling rate: 80...
Product detailsAdd to RFQ
TMM88B-PKC090 - Sick
Performance: Number of axis: 2; Measuring range: ± 90°; Resolution: 0.01°; Accuracy: ≤ ± 60°, typ. ± 0.1°, max. ± 0.2°≤ ± 80°, typ. ± 0.2°, max. ± 0.4°; Compensated cross-sensitivity (2-dimensional): Typ. ± 0.09°, max. ± 0.45°; Temperature coefficient (zero point): Typ. ±0.01°/K 1); Limit frequency: 0.1 Hz ... 25 Hz, 8. range (with digital filter); Sampling rate: 80...
Product detailsAdd to RFQ
TIM320-1131000 - Sick
TiM3xx / TiM32x / Indoor / Short Range. Scanning frequency: 15 Hz. Operating range: 0.05 m ... 4 m. Field of view: 270 °.
Product detailsAdd to RFQ
TMM88A-PKC090 - Sick
Performance: Number of axis: 2; Measuring range: ± 90°; Resolution: 0.01°; Accuracy: ≤ ± 60°, typ. ± 0.02°, max. ± 0.06°≤ ± 70°, typ. ± 0.04°, max. ± 0.12°≤ ± 80°, typ. ± 0.08°, max. ± 0.24°≤ ± 85°, typ. ± 0.16°, max. ± 0.48°; Compensated cross-sensitivity (2-dimensional): Typ. ± 0.09°, max. ± 0.45°; Temperature coefficient (zero point): Typ. +0.0088°/K,...
Product detailsAdd to RFQ
TMM88A-PLC090 - Sick
Performance: Number of axis: 2; Measuring range: ± 90°; Resolution: 0.01°; Accuracy: ≤ ± 60°, typ. ± 0.02°, max. ± 0.06°≤ ± 70°, typ. ± 0.04°, max. ± 0.12°≤ ± 80°, typ. ± 0.08°, max. ± 0.24°≤ ± 85°, typ. ± 0.16°, max. ± 0.48°; Compensated cross-sensitivity (2-dimensional): Typ. ± 0.09°, max. ± 0.45°; Temperature coefficient (zero point): Typ. ±0.0083°/K...
Product detailsAdd to RFQ
TMM88A-PCI090 - Sick
Performance: Number of axis: 2; Measuring range: ± 90°; Resolution: 0.01°; Accuracy: ≤ ± 60°, typ. ± 0.02°, max. ± 0.05°≤ ± 70°, typ. ± 0.04°, max. ± 0.1°≤ ± 80°, typ. ± 0.08°, max. ± 0.2°≤ ± 85°, typ. ± 0.16°, max. ± 0.4°; Compensated cross-sensitivity (2-dimensional): Typ. ± 0.09°, max. ± 0.45°; Temperature coefficient (zero point): Typ. ±0.008°/K...
Product detailsAdd to RFQ
THTS-1PBD50506MZ - Sick
Features: Measuring range: –50 °C +250 °C; Sensor element: Pt100, Pt1000 (for 4 mA ... 20 mA version); Output signal: Pt100, 4-wire; Mechanics/electronics: Process connection: Clamp (DIN 32676) DN 50; Insertion length/diameter of probe: 50 mm / 6 mm; Wetted parts: Stainless steel 1.4435 / 316L, Ra ≤ 0.8 µm; Pressure resistance: Max. 16 bar at room temperature; Housing material:...