Siemens

[siemens_summary]
[catalog_children]
[catalog_search_products]

Siemens ⍾ Page 1575

Product detailsAdd to RFQ
3UG4816-2AA40 - Siemens
Digital monitoring relay for 3-phase voltage with N-conductor for IO-Link 50...60 Hz AC 3 x 160 to 690 V Phase sequence, Phase failure Phase asymmetry Undervoltage and overvoltage Hysteresis 1-20 V Line stabilization delay Tripping delay time 1 change-over contact, spring-type connection system
Product detailsAdd to RFQ
3UG4651-1AW30 - Siemens
Digital monitoring relay Speed monitoring from 0.1 to 2200 rpm Overshoot and undershoot 24 to 240 V AC/DC 50 to 60 Hz DC and AC ON delay 1 to 900 s Tripping delay 0.1 to 99.9 s Hysteresis 0.1 to 99 rpm 1 change-over contact with or without fault buffer screw terminal Successor product for 3UG3051
Product detailsAdd to RFQ
3UG4816-1AA40 - Siemens
Digital monitoring relay for 3-phase voltage with N-conductor for IO-Link 50...60 Hz AC 3 x 160 to 690 V Phase sequence, Phase failure Phase asymmetry Undervoltage and overvoltage Hysteresis 1-20 V Line stabilization delay Tripping delay time 1 change-over contact, screw terminal
Product detailsAdd to RFQ
3UG4651-2AA30 - Siemens
Digital monitoring relay Speed monitoring from 0.1 to 2200 rpm 0vershoot and undershoot Supply voltage: 24 V AC/DC 50 to 60 Hz DC and AC without galvanic isolation to measuring circuit ON delay 1 to 900 s Tripping delay 0.1 to 99.9 s Hysteresis 0.1 to 99 rpm 1 change-over contact with or without fault buffer spring-type connection system
Product detailsAdd to RFQ
3UG4815-2AA40 - Siemens
DIGITAL MONITORING RELAY FOR 3-PHASE MAINS VOLTAGE FOR IO-LINK AC 50 TO 60 HZ 3X 160 TO 690V LINE PHASE SEQUENCE, PHASE FAILURE, PHASE ASYMMETRY UNDER- AND OVERVOLTAGE HYSTERESIS 1-20V NETWORK STABILITY TIME TRIGGER DELAY TIME 1 CHANGEOVER, SPRING BALANCER TECHNOLOGY
Product detailsAdd to RFQ
3UG4651-2AW30 - Siemens
Digital monitoring relay Speed monitoring from 0.1 to 2200 rpm Overshoot and undershoot 24 to 240 V AC/DC 50 to 60 Hz DC and AC ON delay 1 to 900 s Tripping delay 0.1 to 99.9 s Hysteresis 0.1 to 99 rpm 1 change-over contact with or without fault buffer spring-type connection system
Product detailsAdd to RFQ
3UG4631-2AA30 - Siemens
Digital monitoring relay Voltage monitoring, 22.5 mm from 0.1-60 V AC/DC 0vershoot and undershoot Supply voltage: 24 V AC/DC 50 to 60 Hz DC and AC without galvanic isolation to measuring circuit Noise pulses delay 0.1 to 20 s Hysteresis 0.1 to 30 V 1 change-over contact with or without fault buffer spring-type connection system
Product detailsAdd to RFQ
3UG4631-1AW38-0AA4-Z X95 - Siemens
DIGITAL MONITORING RELAY VOLTAGE MONITORING, 22.5MM FROM 14.3 TO 15.7V AC/DC SUPPLY VOLTAGE AC/DC 24 TO 240V QUIESCENT CURRENT PRINCIPLE NOISE PULSE DELAY 0.1S HYSTERESIS 0.1A 1 CO CONTACT AUTOM. RESET SCREW TERMINAL
Product detailsAdd to RFQ
3UG4651-1AA30 - Siemens
DIGITAL MONITORING RELAY SPEED MONITORING FROM 0.1 TO 2200 REV/MIN OVERSHOOT AND UNDERSHOOT SUPPLY VOLTAGE: AC/DC 24V DC AND AC 50 TO 60 HZ NO GALVANIC ISOLATION FROM MEASURING CIRCUIT STARTUP DELAY 1 TO 900S TRIP DELAY 0.1 TO 99.9S HYSTERESIS 0.1 TO 99 REV/MIN 1 CO CONTACT W. OR W/O ERROR LOG SCREW TERMINAL REPLACEMENT PRODUCT FOR 3UG3051
Product detailsAdd to RFQ
3UG4815-1AA40 - Siemens
Digital monitoring relay 3-phase supply voltage for IO-Link 50...60 Hz AC 3 x 160 to 690 V Phase sequence, Phase failure Phase asymmetry Undervoltage and overvoltage Hysteresis 1-20 V Line stabilization delay Tripping delay time 1 change-over contact, screw terminal
Product detailsAdd to RFQ
3UG4632-2AA30 - Siemens
DIGITAL MONITORING RELAY VOLTAGE MONITORING, 22.5MM FROM 10 TO 600V AC/DC OVERSHOOT AND UNDERSHOOT SUPPLY VOLTAGE: AC/DC 24V DC AND AC 50 TO 60 HZ NO GALVANIC ISOLATION FROM MEASURING CIRCUIT INTERF. PEAK DELAY 0.1 TO 20S HYSTERESIS 0.01 TO 300V 1 CO CONTACT W. OR W/O ERROR LOG SPRING-LOADED CONNECTION
Product detailsAdd to RFQ
3UG4641-2CS20 - Siemens
DIGITAL MONITORING RELAY COS-PHI A. CURRENT MONITORING FROM 90 TO 690V AC OVERSHOOT AND UNDERSHOOT INTERNAL POWER SUPPLY AC 50 TO 60 HZ SPIKE DELAY 0.1 TO 20S HYSTERESIS W. (I) 0.1 TO 2A 2 CHANGEOVER CONTACTS W. OR W/O ERROR LOG SPRING-LOADED TYPE