Siemens

[siemens_summary]
[catalog_children]
[catalog_search_products]

Siemens ⍾ Page 426

Product detailsAdd to RFQ
3VL2706-1DK36-0AA0 - Siemens
CIRCUIT-BREAKER VL 160N STANDARD BREAKING CAPACITY ICU=55KA / 415 V AC 3 POLE, STARTER COMBINATION PROTECTION OVERCURRENT RELEASE MAGNETIC IN=63A, RATED CURRENT II=450-900A, SHORT CIRCUIT WITH SCREW CONNECTION WITHOUT AUXILIARY RELEASE WITHOUT AUXILIARY/ALARM SWITCH
Product detailsAdd to RFQ
3VL2706-1DC33-0AD1 - Siemens
Circuit breaker VL160N standard breaking capacity Icu=55kA, 415V AC 3-pole, line protection Electronic Trip Unit TM, LI In=63A, rated current Ir=50...63A, overload protection, II=300...600A, short-circuit protection without auxiliary release Auxiliary/alarm switch mounting kit 2 AUX (1 NO+1 NC)+1 AS (1 NO)
Product detailsAdd to RFQ
3VL2706-1DC33-0AB1 - Siemens
Circuit-breaker VL 160N standard breaking capacity Icu=55kA / 415 V AC 3 pole, line protection overcurrent release TM, li In=63A, rated current ir=50-63A, overload iI=300-600A, short circuit without auxiliary release Auxiliary switch mounting kit 2 AUX (1 NO + 1 NC)
Product detailsAdd to RFQ
3VL2706-1DC36-0AB1 - Siemens
Circuit-breaker VL 160N standard breaking capacity Icu=55kA / 415 V AC 3 pole, line protection overcurrent release TM, li In=63A, rated current ir=50-63A, overload iI=300-600A, short circuit with screw connection without auxiliary release Auxiliary switch mounting kit 2 AUX (1 NO + 1 NC)
Product detailsAdd to RFQ
3VL2706-1EJ43-0AA0 - Siemens
Circuit breaker VL160N standard breaking capacity Icu=55kA, 415V AC 4-pole, line protection Trip Unit TM, LI In=63A, rated current Ir=50...63A, overload protection, II=300...600A, short-circuit protection N unprotected without auxiliary release without auxiliary/alarm switch
Product detailsAdd to RFQ
3VL2706-1DC36-0AA0 - Siemens
Circuit breaker VL160N standard breaking capacity Icu=55kA, 415V AC 3-pole, line protection Trip Unit TM, LI In=63A, rated current Ir=50...63A, overload protection, II=300...600A, short-circuit protection with screw terminals without auxiliary release without auxiliary/alarm switch
Product detailsAdd to RFQ
3VL2705-1EJ43-8KD1 - Siemens
Circuit breaker VL160N standard breaking capacity Icu=55kA, 415V AC 4-pole, line protection Trip Unit TM, LI In=50A, rated current Ir=40...50A, overload prot. II=300...600A, short-circuit protection, N unprotected N unprotected Shunt release 110...127 V DC Auxiliary/alarm switch mounting kit 2 AUX (1 NO+1 NC)+1 AS (1 NO)
Product detailsAdd to RFQ
3VL2705-1EJ43-0AA0 - Siemens
Circuit breaker VL160N standard breaking capacity Icu=55kA, 415V AC 4-pole, line protection Trip Unit TM, LI In=50A, rated current Ir=40...50A, overload prot. II=300...600A, short-circuit protection, N unprotected N unprotected without auxiliary release without auxiliary/alarm switch
Product detailsAdd to RFQ
3VL2706-1DC33-0AA0 - Siemens
Circuit breaker VL160N standard breaking capacity Icu=55kA, 415V AC 3-pole, line protection Trip Unit TM, LI In=63A, rated current Ir=50...63A, overload protection, II=300...600A, short-circuit protection without auxiliary release without auxiliary/alarm switch
Product detailsAdd to RFQ
3VL2705-1DC33-2DB1 - Siemens
CIRCUIT-BREAKER VL 160N STANDARD BREAKING CAPACITY ICU=55KA / 415 V AC 3 POLE, LINE PROTECTION OVERCURRENT RELEASE TM, LI IN=50A, RATED CURRENT IR=40-50A, OVERLOAD II=300-600A, SHORT CIRCUIT UNDERVOLTAGE RELEASE 24V AC AUXILIARY SWITCH KIT 2HS(1NO+1NC)
Product detailsAdd to RFQ
3VL2591-1KN30-0AD1 - Siemens
Circuit breaker VL150 UL type DG (cat no. NDK3B090) non-interchangeable frame, with circuit breaker approval acc. to UL 489 standard breaking capacity 3-pole; NEMA rating 35KA@480V and 18KA@600/347V (molded case circuit breaker) Electronic Trip Unit TM, LI TA=40°C In=90A, rated current II=500...1000A short-circuit protection Ir=90A Electronic Trip Unit for line protection without connection accessories without auxiliary release Auxiliary/alarm switch mounting...
Product detailsAdd to RFQ
3VL2511-2KN30-0AB1 - Siemens
Circuit breaker VL150 UL Type DG (CAT NO. HDK3B110) non-interchangeable frame, with approval circuit breaker according to UL 489 High switching capacity 3-pole; NEMA rating 65 kA @ 480 V and 18 kA @ 600/347 V (molded case circuit breaker) Overcurrent release TM, LI TU=40 °C In=110 A, Rated current II=550...1100 A Short-circuit protection Ir=110 A overcurrent release for system...