Items 37 - 48 of 74 from SICK ⍾ Last modified Sep 4, 2025

STR1 ⍾ Page 4

Product detailsAdd to RFQ
STR1-SAMU0AC8 - Sick
Features: System part: Sensor and actuator; Sensor principle: Transponder; Number of safe outputs: 2; Auxiliary contact (AUX): 1 (Switching behavior complementary to OSSDs); Safe switch on distance Sao: 14 mm (–10 ... +70 °C) 1)10 mm (–30 ... –10 °C) 1); Safe switch off distance Sar: 28 mm 1); Active sensor surfaces: 3; Actuation directions: 5; Coding: Uniquely coded; Safety-related...
Product detailsAdd to RFQ
STR1-SASF03P5 - Sick
Features: System part: Sensor and actuator; Sensor principle: Transponder; Number of safe outputs: 2; Auxiliary contact (AUX): 1 (Switching behavior complementary to OSSDs); Safe switch on distance Sao: 10 mm (–30 °C ... +70 °C) 1); Safe switch off distance Sar: 25 mm 1); Active sensor surfaces: 3; Actuation directions: 5; Coding: Permanently coded; Safety-related parameters: Safety integrity level: SIL3...
Product detailsAdd to RFQ
STR1-SASF0AC5 - Sick
Features: System part: Sensor and actuator; Sensor principle: Transponder; Number of safe outputs: 2; Auxiliary contact (AUX): 1 (Switching behavior complementary to OSSDs); Safe switch on distance Sao: 10 mm (–30 °C ... +70 °C) 1); Safe switch off distance Sar: 25 mm 1); Active sensor surfaces: 3; Actuation directions: 5; Coding: Permanently coded; Safety-related parameters: Safety integrity level: SIL3...
Product detailsAdd to RFQ
STR1-SAMU10P8 - Sick
Features: System part: Sensor and actuator; Sensor principle: Transponder; Number of safe outputs: 2; Auxiliary contact (AUX): 1 (Switching behavior complementary to OSSDs); Safe switch on distance Sao: 14 mm (–10 ... +70 °C) 1)10 mm (–30 ... –10 °C) 1); Safe switch off distance Sar: 28 mm 1); Active sensor surfaces: 3; Actuation directions: 5; Coding: Uniquely coded; Safety-related...
Product detailsAdd to RFQ
STR1-SASF03P8 - Sick
Features: System part: Sensor and actuator; Sensor principle: Transponder; Number of safe outputs: 2; Auxiliary contact (AUX): 1 (Switching behavior complementary to OSSDs); Safe switch on distance Sao: 10 mm (–30 °C ... +70 °C) 1); Safe switch off distance Sar: 25 mm 1); Active sensor surfaces: 3; Actuation directions: 5; Coding: Permanently coded; Safety-related parameters: Safety integrity level: SIL3...
Product detailsAdd to RFQ
STR1-SASF0AC8 - Sick
Features: System part: Sensor and actuator; Sensor principle: Transponder; Number of safe outputs: 2; Auxiliary contact (AUX): 1 (Switching behavior complementary to OSSDs); Safe switch on distance Sao: 10 mm (–30 °C ... +70 °C) 1); Safe switch off distance Sar: 25 mm 1); Active sensor surfaces: 3; Actuation directions: 5; Coding: Permanently coded; Safety-related parameters: Safety integrity level: SIL3...
Product detailsAdd to RFQ
STR1-SASF10P8 - Sick
Features: System part: Sensor and actuator; Sensor principle: Transponder; Number of safe outputs: 2; Auxiliary contact (AUX): 1 (Switching behavior complementary to OSSDs); Safe switch on distance Sao: 10 mm (–30 °C ... +70 °C) 1); Safe switch off distance Sar: 25 mm 1); Active sensor surfaces: 3; Actuation directions: 5; Coding: Permanently coded; Safety-related parameters: Safety integrity level: SIL3...
Product detailsAdd to RFQ
STR1-SAMM0AC5 - Sick
Features: System part: Sensor and actuator; Sensor principle: Transponder; Number of safe outputs: 2; Auxiliary contact (AUX): 1 (Switching behavior complementary to OSSDs); Safe switch on distance Sao: 14 mm (–10 ... +70 °C) 1)10 mm (–30 ... –10 °C) 1); Safe switch off distance Sar: 28 mm 1); Active sensor surfaces: 3; Actuation directions: 5; Coding: Universally coded; Safety-related...
Product detailsAdd to RFQ
STR1-SASF10P5 - Sick
Features: System part: Sensor and actuator; Sensor principle: Transponder; Number of safe outputs: 2; Auxiliary contact (AUX): 1 (Switching behavior complementary to OSSDs); Safe switch on distance Sao: 10 mm (–30 °C ... +70 °C) 1); Safe switch off distance Sar: 25 mm 1); Active sensor surfaces: 3; Actuation directions: 5; Coding: Permanently coded; Safety-related parameters: Safety integrity level: SIL3...
Product detailsAdd to RFQ
STR1-SAMM10P5 - Sick
Features: System part: Sensor and actuator; Sensor principle: Transponder; Number of safe outputs: 2; Auxiliary contact (AUX): 1 (Switching behavior complementary to OSSDs); Safe switch on distance Sao: 14 mm (–10 ... +70 °C) 1)10 mm (–30 ... –10 °C) 1); Safe switch off distance Sar: 28 mm 1); Active sensor surfaces: 3; Actuation directions: 5; Coding: Universally coded; Safety-related...
Product detailsAdd to RFQ
STR1-SAMM03P5 - Sick
Features: System part: Sensor and actuator; Sensor principle: Transponder; Number of safe outputs: 2; Auxiliary contact (AUX): 1 (Switching behavior complementary to OSSDs); Safe switch on distance Sao: 14 mm (–10 ... +70 °C) 1)10 mm (–30 ... –10 °C) 1); Safe switch off distance Sar: 28 mm 1); Active sensor surfaces: 3; Actuation directions: 5; Coding: Universally coded; Safety-related...
Product detailsAdd to RFQ
STR1-SAMF10P8 - Sick
Features: System part: Sensor and actuator; Sensor principle: Transponder; Number of safe outputs: 2; Auxiliary contact (AUX): 1 (Switching behavior complementary to OSSDs); Safe switch on distance Sao: 14 mm (–10 ... +70 °C) 1)10 mm (–30 ... –10 °C) 1); Safe switch off distance Sar: 28 mm 1); Active sensor surfaces: 3; Actuation directions: 5; Coding: Permanently coded; Safety-related...