[siemens_summary]
[catalog_children]
[catalog_search_products]

Temperature measurement ⍾ Page 20

Product detailsAdd to RFQ
7NG0420-0GA50-0AA0-Z C11 - Siemens
SITRANS TR420 Temperature transmitter for rail mounting, with two separate configurable inputs and a galvanically isolated 2-wire output. HART (4 … 20 mA) Input 1 TC Type E None Input 1: Internal CJC; Input 2: None CJC Without enclosure (head mounted and rail mounted transmitter) - General purpose (CE, RCM, FM, KCC, EAC, CSA) None (head mounted and rail mounted...
Product detailsAdd to RFQ
7NG0350-0BA01-0AM2-Z C11 - Siemens
SITRANS TF320 Temperature transmitter with dual chamber enclosure for wall or pipe mounting, one configurable input and a galvanically isolated 2-wire output. HART (4 … 20 mA) Input 1 RTD Pt100 IEC 60751 3-wire None None CJC Die-cast aluminum enclosure - General purpose 2 x 1/2''-14 NPT / closed Local operation (lid with glass window) Inspection certificate DIN EN 10204-3.1:...
Product detailsAdd to RFQ
7NG0340-0BA01-0BM2-Z E20 - Siemens
SITRANS TF320 Temperature transmitter with single chamber enclosure for wall or pipe mounting, one configurable input and a galvanically isolated 2-wire output. HART (4 … 20 mA) Input 1 RTD Pt100 IEC 60751 3-wire None None CJC Die-cast aluminum enclosure - Intrinsic safety (Ex i) / Non-incendive field wiring (NIFW) 2 x 1/2'' NPT Local operation (lid with glass window)...
Product detailsAdd to RFQ
7NG0350-0BA01-0AM2-Z A00 - Siemens
SITRANS TF320 Temperature transmitter with dual chamber enclosure for wall or pipe mounting, one configurable input and a galvanically isolated 2-wire output. HART (4 … 20 mA) Input 1 RTD Pt100 IEC 60751 3-wire None None CJC Die-cast aluminum enclosure - General purpose 2 x 1/2''-14 NPT / closed Local operation (lid with glass window) Cable gland included, plastic General...
Product detailsAdd to RFQ
7NG0420-1JC50-0AA0 - Siemens
SITRANS TR420 Temperature transmitter for rail mounting, with two separate configurable inputs and a galvanically isolated 2-wire output. HART (4 … 20 mA) Input 1, input 2 as backup TC Type K RTD Pt100 IEC 60751 4-wire Input 1: Internal CJC; Input 2: None CJC Without enclosure (head mounted and rail mounted transmitter) - General purpose (CE, RCM, FM, KCC,...
Product detailsAdd to RFQ
7NG0410-1BB00-0NA0 - Siemens
SITRANS TH420 Temperature transmitter for installation in connection head type B (DIN 43729), with two separate configurable inputs and a galvanically isolated 2-wire output. HART (4 … 20 mA) Input 1, input 2 as backup RTD Pt100 IEC 60751 3-wire RTD Pt100 IEC 60751 3-wire Input 1: None CJC ; Input 2: None CJC Without enclosure (head mounted and rail...
Product detailsAdd to RFQ
7NG0340-0BA01-0AM2-Z A00 - Siemens
SITRANS TF320 Temperature transmitter with single chamber enclosure for wall or pipe mounting, one configurable input and a galvanically isolated 2-wire output. HART (4 … 20 mA) Input 1 RTD Pt100 IEC 60751 3-wire None None CJC Die-cast aluminum enclosure - General purpose 2 x 1/2'' NPT Local operation (lid with glass window) Cable gland included, plastic General approval without...
Product detailsAdd to RFQ
7NG0340-0BA03-0SF2-Z C11 - Siemens
SITRANS TF320 Temperature transmitter with single chamber enclosure for wall or pipe mounting, one configurable input and a galvanically isolated 2-wire output. HART (4 … 20 mA) Input 1 RTD Pt100 IEC 60751 3-wire None None CJC Enclosure made of stainless steel precision casting 1.4401 (similar to 316) - Flameproof enclosure (Ex d) / Intrinsic safety (Ex i) / Dust...
Product detailsAdd to RFQ
7NG0340-0BA01-0BM2-Z E22 - Siemens
SITRANS TF320 Temperature transmitter with single chamber enclosure for wall or pipe mounting, one configurable input and a galvanically isolated 2-wire output. HART (4 … 20 mA) Input 1 RTD Pt100 IEC 60751 3-wire None None CJC Die-cast aluminum enclosure - Intrinsic safety (Ex i) / Non-incendive field wiring (NIFW) 2 x 1/2'' NPT Local operation (lid with glass window)...
Product detailsAdd to RFQ
7NG0340-0BA01-0AM2-Z E00 - Siemens
SITRANS TF320 Temperature transmitter with single chamber enclosure for wall or pipe mounting, one configurable input and a galvanically isolated 2-wire output. HART (4 … 20 mA) Input 1 RTD Pt100 IEC 60751 3-wire None None CJC Die-cast aluminum enclosure - General purpose 2 x 1/2'' NPT Local operation (lid with glass window) General approval without Ex approval: World (CE,...
Product detailsAdd to RFQ
7NG0320-0JA30-0NA0 - Siemens
SITRANS TR320 Temperature transmitter for rail mounting, with one configurable input and a galvanically isolated 2-wire output. HART (4 … 20 mA) Input 1 TC Type K None External CJC RTD Pt100 IEC 60751 3 Wire Without enclosure (head mounted and rail mounted transmitter) - Intrinsic safety (Ex i) / Increased safety zone 2 (Ex ec) / Non-incendive (NI) /...
Product detailsAdd to RFQ
7NG0340-0BA01-0AM2-Z A00 - Siemens
SITRANS TF320 Temperature transmitter with single chamber enclosure for wall or pipe mounting, one configurable input and a galvanically isolated 2-wire output. HART (4 … 20 mA) Input 1 RTD Pt100 IEC 60751 3-wire None None CJC Die-cast aluminum enclosure - General purpose 2 x 1/2'' NPT Local operation (lid with glass window) Cable gland included, plastic General approval without...