PN016A - Ifm
Pressure sensor with display; Operating voltage [V] : 18...36 DC;  (to SELV/PELV); Protection class : III; Reverse polarity protection : yes; Overvoltage protection : yes;  (< 40 V); Power-on delay time [s] : 0.3; Integrated watchdog : yes; Total number of outputs : 2; Output signal : switching signal; IO-Link;  (configurable); Electrical design : PNP/NPN; Number of digital outputs : 2; Output function : normally open / normally closed;  (parameterisable); Max. voltage drop switching output DC [V] : 2; Permanent current rating of switching output DC [mA] : 250; Switching frequency DC [Hz] : < 170; Short-circuit protection : yes; Type of short-circuit protection : pulsed; Measuring range : 0...2.5 bar: 0...2500 mbar: 0...36.3 psi: 0...250 kPa; Set point SP : 0.02...2.5 bar: 0.4...36.2 psi: 2...250 kPa; Reset point rP : 0.01...2.49 bar: 0.2...36 psi: 1...249 kPa; In steps of : 0.01 bar: 0.2 psi: 1 kPa; Factory setting : SP1 = 0.63 bar: rP1 = 0.58 bar | SP2 = 1.88 bar: rP2 = 1.83 bar; Switch point accuracy [% of the span] : < ± 0,5; Repeatability [% of the span] : < ± 0,1;  (with temperature fluctuations < 10 K); Characteristics deviation [% of the span] : < ± 0,25 (BFSL) / < ± 0,5 (LS);  (BFSL = Best Fit Straight Line; LS = limit value setting); Hysteresis deviation [% of the span] : < ± 0,25; Long-term stability [% of the span] : < ± 0,05;  (per 6 months); Temperature coefficient zero point [% of the span / 10 K] : 0,2;  (0...60 °C); Temperature coefficient span [% of the span / 10 K] : 0,2;  (0...60 °C); Delay time programmable dS, dr [s] : 0; 0,2...50; Parameter setting options : hysteresis / window; normally open / normally closed; diagnostic function; switching logic; switch-on/switch-off delay; Damping; Display unit; Communication interface : IO-Link; Transmission type : COM2 (38,4 kBaud); IO-Link revision : 1.1; SDCI standard : IEC 61131-9 CDV; Profiles : no profile; SIO mode : yes; Required master port type : A; Process data analogue : 1; Process data binary : 2; Min. process cycle time [ms] : 2.3; Supported DeviceIDs : Type of operation: DeviceID | Default: 312; Ambient temperature [°C] : -20...60; Storage temperature [°C] : -40...100; Materials : stainless steel (1.4301 / 304); stainless steel (1.4404 / 316L); PC; PBT; PEI; FKM; PTFE; Materials (wetted parts) : stainless steel (1.4305 / 303); ceramics; FKM; Min. pressure cycles : 100 million; Process connection : threaded connection G 1/4 internal thread; Restrictor element integrated : no (can be retrofitted); Connector: 1 x M12; Contacts: gold-plated