Catalog>IFM>Ifm – SA4110

Ifm – SA4110

IFM Ifm – SA4110
Qty
Flow sensor; Operating voltage [V] : 18…30 DC; Protection class : III; Reverse polarity protection : yes; Power-on delay time [s] : 10; Total number of outputs : 2; Output signal : switching signal; analogue signal; frequency signal; IO-Link; (configurable); Electrical design : PNP/NPN; Number of digital outputs : 2; Output function : normally open / normally closed; (parameterisable); Max. voltage drop switching output DC [V] : 2.5; Permanent current rating of switching output DC [mA] : 250; Number of analogue outputs : 1; Analogue current output [mA] : 4…20; (scalable); Max. load [Ω] : 350; Short-circuit protection : yes; Type of short-circuit protection : pulsed; Overload protection : yes; Frequency of the output [Hz] : 0…1000; Probe length L [mm] : 100; Operating mode : relative; absolutely liquid; absolutely gaseous; (absolute: reference measurement recommended); Note on factory setting : Operating mode: relative; Dynamic response T05 / T09 [s] : 1,5 (T09); (water; flow velocity: 1…9,85 fps); Setting range [ft/s] : 0…9.85; Greatest sensitivity [ft/s] : 0.15…9.85; Setting range [ft/s] : 0…19.5; Setting range [ft/s] : 0…328; Greatest sensitivity [ft/s] : 6…328; Setting range [ft/s] : 0…656; Temperature drift [cm/s x 1/K] : 0,01 fps x 1/K ( 158 °F); Temperature gradient [K/min] : 100; Repeatability : 0,05 m/s; (water; flow velocity: 0,05…3 m/s); Accuracy : ± (7 % MW + 2 % MEW); (for relative mode in the range of maximum sensitivity under the following conditions: water: 68…158 °F; inlet length: 5 ft; DN25 (DIN 2448); mounting position according to instructions; Accuracy can differ for other media and mounting positions.); Response time [s] : 0.5; (T09; water; glycol: 0,8 s; air: 7 s; oil: 1,8 s; each T09); Parameter setting options : hysteresis / window; normally open / normally closed; switching logic; current/frequency output; medium selection; Damping; Teach function; display can be rotated and switched off; standard unit of measurement; process value colour; Communication interface : IO-Link; Transmission type : COM2 (38,4 kBaud); IO-Link revision : 1.1; SDCI standard : IEC 61131-9; Profiles : Smart Sensor: Process Data Variable; Device Identification, Device Diagnosis; SIO mode : yes; Required master port type : A; Process data analogue : 2; Process data binary : 2; Min. process cycle time [ms] : 3; Supported DeviceIDs : Type of operation: DeviceID | Factory setting / ModE = (REL): 537 | ModE = (LIQU): 544 | ModE = (GAS): 551; Ambient temperature [°F] : -40…176; Storage temperature [°F] : -40…212; Materials : stainless steel (1.4404 / 316L); PBT-GF20; PBT-GF30; Materials (wetted parts) : stainless steel (1.4404 / 316L); Process connection : diameter Ø 8 mm
ConnectionConnector: 1 x M12; Contacts: gold-plated
No. of inputs/outputsNumber of digital outputs: 2; Number of analogue outputs: 1
Current consumption< 100 mA
Voltage supply24 V
DisplayDisplay unit: 6 x LED, green (%, fps, gpm, cfm, u00b0F, 10u00b3) | switching status: 2 x LED, yellow | measured values: alphanumeric display, red/green 4-digit
Degree of protectionIP 65; IP 67
Weight296.5 g
Dimensionsu00d8 58 / L = 80.2 mm

Downloads

PDF
IFM SA4110 Datasheet PDF
Download

Related in IFM ⍾ Page 1