Ifm – SD6101
Flow rate meter for gases; Measuring range : 15…4310 scfh: 0.2…71.8 scfm: 2…552 sfs; Display range : 0…5170 scfh: 0…86.2 scfm: 0…663 sfs; Resolution : 5 scfh: 0.1 scfm: 1 sfs; Set point SP : 40…4310 scfh: 0.7…71.8 scfm: 5…552 sfs; Reset point rP : 20…4290 scfh: 0.4…71.5 scfm: 3…550 sfs; Analogue start point ASP : 0…3445 scfh: 0…57.4 scfm: 0…442 sfs; Analogue end point AEP : 860…4310 scfh: 14.4…71.8 scfm: 110…552 sfs; In steps of : 5 scfh: 0.1 scfm: 1 sfs; Measuring range : 10…2640 scfh: 0.15…44 scfm: 1…338.5 sfs; Display range : 0…3170 scfh: 0…52.8 scfm: 0…406 sfs; Resolution : 5 scfh: 0.05 scfm: 0.5 sfs; Set point SP : 25…2640 scfh: 0.4…44 scfm: 3…338.5 sfs; Reset point rP : 15…2630 scfh: 0.2…43.8 scfm: 1.5…337 sfs; Analogue start point ASP : 0…2110 scfh: 0…35.2 scfm: 0…271 sfs; Analogue end point AEP : 530…2640 scfh: 8.8…44 scfm: 67.5…338.5 sfs; In steps of : 5 scfh: 0.05 scfm: 0.5 sfs; Measuring range : 10…2650 scfh: 0.15…44.15 scfm: 1…339.5 sfs; Display range : 0…3175 scfh: 0…52.95 scfm: 0…407.5 sfs; Set point SP : 25…2650 scfh: 0.4…44.15 scfm: 3…339.5 sfs; Reset point rP : 15…2635 scfh: 0.2…43.95 scfm: 1.5…338 sfs; Analogue start point ASP : 0…2120 scfh: 0…35.3 scfm: 0…271.5 sfs; Analogue end point AEP : 530…2650 scfh: 8.85…44.15 scfm: 68…339.5 sfs; Operating voltage [V] : 18…30 DC; (according to EN 50178 SELV/PELV); Protection class : III; Reverse polarity protection : yes; Power-on delay time [s] : 1; Total number of outputs : 2; Output signal : switching signal; analogue signal; pulse signal; IO-Link; (configurable); Electrical design : PNP; Number of digital outputs : 2; Output function : normally open / normally closed; (parameterisable); Max. voltage drop switching output DC [V] : 2; Permanent current rating of switching output DC [mA] : 250; (per output); Number of analogue outputs : 1; Analogue current output [mA] : 4…20; (scalable); Max. load [Ω] : 500; Pulse output : consumed quantity meter; Short-circuit protection : yes; Type of short-circuit protection : pulsed; Overload protection : yes; Low flow cut-off LFC : < 46 scfh: < 0.76 scfm: 1…5.8 sfs; Measuring dynamics : 1:300; Pulse value : 0.040…4 000 000 scf; In steps of : 0.020…1000 scf; Pulse length [s] : 0,007…2; Accuracy [K] : ± 2; (medium flow in the limit area of the flow measurement range); Response time [s] : 0.1; (dAP = 0); Damping for the switching output dAP in steps [s] : 0 – 0,2 – 0,4 – 0,6 – 0,8 – 1; Parameter setting options : Flow monitoring; quantity meter; Preset counter; hysteresis / window; normally open / normally closed; current/pulse output; display can be rotated and switched off; Display unit; medium selection; Communication interface : IO-Link; Transmission type : COM2 (38,4 kBaud); IO-Link revision : 1.1; SDCI standard : IEC 61131-9; Profiles : Smart Sensor: Process Data Variable; Device Identification, Device Diagnosis; SIO mode : yes; Required master port type : A; Process data analogue : 3; Process data binary : 2; Min. process cycle time [ms] : 4.1; Supported DeviceIDs : Type of operation: DeviceID | Default: 266; Ambient temperature [°F] : 32…140; Storage temperature [°F] : -4…185; Max. relative air humidity [%] : 90; Materials : PBT-GF20; PC; PC; stainless steel (1.4301 / 304); FKM; Materials (wetted parts) : stainless steel (1.4301 / 304); ceramics glass passivated; PEEK; polyester; FKM; aluminium anodised; Process connection : threaded connection 1/2" NPT DN15; Display unit : scfm; scfh; scf; °F