Ifm – SU9004
Ultrasonic flow meter; Operating voltage [V] : 19…30 DC; (according to EN 50178 SELV/PELV); Min. insulation resistance [MΩ] : 100; (500 V DC); Protection class : III; Reverse polarity protection : yes; Power-on delay time [s] : 10; Total number of outputs : 2; Output signal : analogue signal; Number of analogue outputs : 2; Analogue current output [mA] : 4…20; (scalable); Max. load [Ω] : 500; Short-circuit protection : yes; Type of short-circuit protection : pulsed; Overload protection : yes; Measuring range : 0…200 l/min: 0…52.84 gpm; Display range : 0…240 l/min: 0…63.42 gpm; Resolution : 0.1 l/min: 0.02 gpm; Analogue start point ASP : 0…160 l/min: 0…42.28 gpm; Analogue end point AEP : 40…200 l/min: 10.28…52.84 gpm; Max. flow rate [l/min] : 220; In steps of : 0.1 l/min: 0.02 gpm; Dynamic response T05 / T09 [s] : T09 = 30 (Q > 20 l/min); (water); Response time [s] : 0.25; (dAP = 0); Damping for the switching output dAP [s] : 0…1; Ambient temperature [°C] : -10…60; Storage temperature [°C] : -25…80; Materials : housing: AlMgSi0,5 anodised; Sealing: FKM; PA 6.6; cover film: PA; Materials (wetted parts) : stainless steel (1.4404 / 316L); FKM; PPS; Centellen 200; Process connection : threaded connection G 1 1/4 flat seal; Display unit : l/min; m³/h; gpm; gph; °C; °F; Items supplied : sealings: 2, Centellen; Accessories (optional) : adapter for pipe: 1 x R 1, stainless steel, E40205 | adapter for pipe: 1 x 1″ NPT, stainless steel, E40206